Air Conditioning Lab Unit | PolarX - 556

Category: Refrigeration and Air Conditioning  ·  Country of Origin: India

Product Overview

The Air Conditioning Lab Unit PolarX - 556 studies the effect of individual HVAC components on room air conditioning using an open air duct system. This Air Conditioning Lab Unit includes an air cooler, steam humidifier (500g/h, three stages), fan (810m³/h max), air preheater (2kW), and reheater (1kW), all individually switchable. Sensors monitor temperature (9 Type-k, -40~400°C), humidity (5 sensors, 0~100%), and refrigerant pressure/temperature before and after each stage. Optional LABVIEW-based DAQ software supports automated data transmission to a PC.

Air Conditioning Lab Unit | PolarX - 556
Request a QuoteWhatsApp +91 7015865225
[email protected]

Technical Specifications

Air Conditioning Lab Unit PolarX - 556, Technical Specifications

Component Type / Detail
System Type Air conditioning system with open air duct
Components Air cooler, steam humidifier, fan, air preheaters, reheaters
Air Flow Determination Differential pressure measurement using inclined tube manometer
Component Control All components individually switchable on and off
Sensors Combined air humidity and temperature sensors before and after each stage
Refrigerant Sensor Pressure and temperature sensor for refrigerant
Refrigerant R134a, CFC-free

Technical Data

Steam Humidifier

Parameter Value
Power Consumption 2x250W
Steam Capacity 500g/h, switchable in three stages

Fan

Parameter Value
Power Consumption 190W
Max. Volume Flow 810m³/h
Speed 500~1100rpm
dpmax 420Pa

Air Heating

Parameter Value
Air Preheater 2kW, switchable in two stages
Air Reheater 1kW, switchable in two stages

Air Duct

Parameter Value
W x H 300x360mm

Direct Evaporator (Air Cooler)

Parameter Value
Capacity 4.5kW

Condensing Unit

Parameter Value
Power Consumption 950W at 5/25°C
Refrigeration Capacity 2kW at 5/25°C

Cabinet (PolarX - 556)

Parameter Value
Function Cabinet for measuring and maintaining HVAC condition according to ASHRAE standards for summers and winters (optional)

Pressure Safety Switch

Side Value
Delivery Side Not specified
Suction Side Not specified

Temperature Sensor

Parameter Value
Range -40~400°C
Type Type-k
Total 9

Humidity Sensor

Parameter Value
Total 5
Range 0~100%

Digital Multifunctional Power Meter

Parameter Value
Range of AC Volt 0~500 volts
Range of AC Ampere 0~40 Ampere

Differential Pressure (Air Flow)

Parameter Value
Range 0~100Pa

Refrigerant Pressure Gauges

Parameter Value
Suction Side (low pressure gauge) -1~16bar
Delivery Side (high pressure gauge) -1~25bar

Flow Rate (Refrigerant)

Parameter Value
Range 8~102L/h

Liquid Receiver

Parameter Value
Maximum Working Pressure 450psig
Capacity 1.2L

Filter Drier

Parameter Value
Maximum Working Pressure 450psig

Key Features

Key Features

Experiments

Construction and Design
The Air Conditioning Lab Unit PolarX - 556 uses an open air duct system incorporating an air cooler, steam humidifier, fan, air preheaters, and reheaters. All components can be switched on and off individually to study their individual and combined effects. Combined sensors for air humidity and temperature are placed before and after each stage, and a sensor monitors the pressure and temperature of the refrigerant. Air flow is determined using differential pressure measurement via an inclined tube manometer. The system runs on R134a refrigerant, which is CFC-free.

Software
PolarX - 556 (optional). A DAQ software package, specially designed in National Instruments LABVIEW environment, measures and calculates the results of the apparatus. The software is optional. When the software is used, a set of electronic sensors is included. The software can be run on any Windows environment.

Scope of Delivery

Standards & Compliance

Ordering & Delivery

Frequently Asked Questions

Q: What components make up the Air Conditioning Lab Unit PolarX - 556?
A: An air cooler (direct evaporator with condensing unit), steam humidifier, fan, air preheaters, and reheaters, all placed in an open air duct.

Q: Can individual components be tested separately?
A: Yes. All components can be switched on and off individually to study their individual and combined effects on air conditioning.

Q: How is air flow measured?
A: Air flow is determined by differential pressure measurement using an inclined tube manometer, with a range of 0~100Pa.

Q: How many temperature and humidity sensors are included?
A: 9 Type-k temperature sensors (range -40~400°C) and 5 humidity sensors (range 0~100%).

Q: Is the DAQ software required to operate the unit?
A: No. The PolarX - 556 software is optional, and data gathering software is not required for standard operation.