Air Conditioning Test Rig (Duct Type)
Model PolarX 556A
The Air Conditioning Test Rig (Duct Type) PolarX 556A is a 1 TR trainer for air conditioning and refrigeration studies. This air conditioning test rig includes cooling, heating, and steam humidification, six PT-100 sensors, and digital electrical metering with HP and LP cutout protection.
The Air Conditioning Test Rig (Duct Type) PolarX 556A is a 1 TR duct-type trainer for studying air conditioning and refrigeration processes. This air conditioning test rig covers cooling, heating, and steam humidification.
Product Overview
The PolarX 556A air conditioning test rig combines a 1 TR refrigeration circuit with a duct-type air conditioning section. Cooling, heating, and humidification experiments are possible on one rig. A steam generator and steam injector provide humidification. Six PT-100 sensors measure air and refrigerant conditions. Pressure, refrigerant flow, air velocity, voltage, current, and energy are all measured. High-pressure and low-pressure cutouts protect the refrigeration circuit.
Air Conditioning Test Rig (Duct Type) PolarX 556A: Technical Specifications
| Parameter | Value |
|---|---|
| Equipment Type | Duct-type air conditioning test rig |
| Refrigeration Capacity | 1 TR |
| Compressor | Hermetically sealed, industrial grade |
| Compressor Cooling Capacity | Approximately 3.5 kW |
| Refrigerant | R-134a, R-32, or R-290 (R-22 not used) |
| Condenser | Air-cooled finned-tube with axial fan |
| Humidification | Steam generator and steam injector |
| Temperature Sensors | 6 PT-100 RTD |
| Pressure Measurement | High-side and low-side gauges/transducers |
| Refrigerant Flow | Calibrated glass-tube rotameter |
| Air Velocity | Anemometer |
| Voltage and Current | Digital panel meters |
| Energy Measurement | Digital kWh meter |
| High-Pressure Protection | HP cutout |
| Low-Pressure Protection | LP cutout |
| Electrical Protection | Thermal overload protection and MCBs |
Technical Data
Refrigeration:
- Capacity: 1 TR
- Compressor: hermetically sealed, industrial grade
- Compressor cooling capacity: approximately 3.5 kW
- Condenser: air-cooled finned-tube with axial fan
Air Conditioning:
- Duct-type arrangement
- Cooling coil and cooling circuit
- Heating arrangement
- Steam generator and steam injector for humidification
Instrumentation:
- 6 PT-100 RTD temperature sensors
- High-side and low-side pressure measurement
- Calibrated glass-tube rotameter for refrigerant flow
- Anemometer for air velocity
- Digital panel meters for voltage and current
- Digital kWh meter for energy
Safety:
- High-pressure cutout
- Low-pressure cutout
- Thermal overload protection
- MCBs
Key Features
- Duct-Type Layout: Air conditioning processes studied in a duct arrangement
- 1 TR Refrigeration: Vapour-compression cycle with hermetically sealed compressor
- Humidification Study: Steam generator and injector for controlled humidity experiments
- Multi-Point Sensing: 6 PT-100 sensors for air and refrigerant temperatures
- Full Electrical Monitoring: Voltage, current, and energy measured by digital meters
- Refrigerant Safety: High-pressure and low-pressure cutouts with thermal overload protection
Experiments
- Basic vapour-compression refrigeration cycle study
- Duct-type air conditioning system operation
- Dry-bulb and wet-bulb temperature measurement
- Air cooling across the cooling coil
- Air heating and its effect on air properties
- Air humidification using steam generator and injector
- High-side and low-side refrigeration pressure measurement
- Refrigerant flow measurement using rotameter
- Air velocity measurement using anemometer
- Refrigerant operating conditions at circuit points
- Voltage, current, and energy consumption measurement
- Combined cooling, heating, and humidification processes
- Refrigeration safety and protective device study
Construction and Design
The PolarX 556A air conditioning test rig uses a hermetically sealed compressor and an air-cooled finned-tube condenser with axial fan. A cooling coil and heating arrangement sit within the duct section. A steam generator and injector add humidity to the air stream. Temperature sensors and pressure points cover the air and refrigerant circuits. Digital meters display electrical readings, and cutouts and MCBs protect the system.
Scope of Delivery
- 1 Air conditioning test rig (duct type), 1 TR
- Hermetically sealed compressor
- Air-cooled finned-tube condenser with axial fan
- Cooling coil and heating arrangement
- Steam generator and steam injector
- 6 PT-100 RTD temperature sensors
- High-side and low-side pressure gauges/transducers
- Calibrated glass-tube rotameter
- Anemometer
- Digital voltage, current, and kWh panel meters
- HP and LP cutouts, thermal overload protection, and MCBs
Q: What does the Air Conditioning Test Rig (Duct Type) PolarX 556A study?
A: It studies refrigeration cycles, air cooling, air heating, and humidification in a duct-type arrangement.
Q: What refrigerants can be used with the PolarX 556A?
A: R-134a, R-32, or R-290 can be used. R-22 is not used.
Q: How is humidity added to the air on the PolarX 556A?
A: A steam generator and steam injector provide humidification for experiments.
Q: What measurements does the PolarX 556A provide?
A: It measures dry-bulb and wet-bulb temperatures, high-side and low-side pressures, refrigerant flow, air velocity, voltage, current, and energy.
Need Assistance? We're Here to Help!
Connect with our team for product specifications, pricing, and customized solutions for your institution or project.








