Scientico IndiaManufacturer & Exporter · Ambala · Since 1993
ISO 9001:2015CE MARKED60+ COUNTRIES

Batch Distillation Column Apparatus | OperatiX - 04

Category: Unit Operations  ·  Country of Origin: India

Product Overview

The Batch Distillation Column Apparatus OperatiX - 04 separates ethanol and water mixtures through batch rectification. This Batch Distillation Column Apparatus features an electrically heated evaporator, coiled condensers, and adjustable reflux ratio control. It supports vacuum mode operation and works with interchangeable optional column types. Optional DAQ software enables measurement and calculation of results.

Batch Distillation Column Apparatus | OperatiX - 04
Request a QuoteWhatsApp +91 7015865225
[email protected]

Technical Specifications

Batch Distillation Column Apparatus OperatiX - 04, Technical Specifications

Specification Detail
Process Batch rectification with different types of columns available as optional
Evaporator Electrically heated, infinitely varied power
Tanks Feed and top product tanks
Product Cooler Coiled condenser
Top Product Condensing Coiled condenser and phase separation tank
Tank Materials All tanks made of glass and stainless steel
Reflux Ratio Adjustment Using valves
Vacuum Mode Possible with vacuum pump
Temperature Sensors Different sensors per column
Pressure Gauge Measures the vacuum in the system

Technical Data

Feed Pump

Parameter Value
Max. flow rate 400mL/min
Speed Variable

Vacuum Pump

Parameter Value
Final vacuum 200mbar

Tanks

Parameter Value
Feed approx. 10L
Boiler approx. 7L
Top Product tank approx. 5L
Phase separation tank approx. 0.5L

Condenser

Parameter Value
Top product condenser material Glass
Top product condenser type Shell and coiled
Product cooler condenser material Glass
Product cooler condenser type Shell and coiled

Rotameter

Parameter Value
Top Product condenser 1~7lpm
Product cooler 1~7lpm

Measuring Ranges

Parameter Value
Temperature -100~400°C
Reflux ratio 0~100%
Heating power 0~2kW
Column differential pressure 0~250mbar
Cooling water flow rate 1~7lpm
System pressure gauge -1~1bar

Key Features

Key Features

Experiments

Construction and Design

The Batch Distillation Column Apparatus OperatiX - 04 is built around an electrically heated evaporator with infinitely varied power. A feed pump delivers flow at a maximum rate of 400mL/min at variable speed. Feed, boiler, top product, and phase separation tanks are made of glass and stainless steel, with capacities of approximately 10L, 7L, 5L, and 0.5L respectively. A coiled condenser cools the product, while a separate coiled condenser and phase separation tank condense the top product. Rotameters measure flow at the top product condenser and product cooler, each ranged 1 to 7lpm. Reflux ratio is adjusted using valves. A vacuum pump enables vacuum mode operation, reaching a final vacuum of 200mbar. Different temperature sensors are fitted per column, and a pressure gauge measures the vacuum in the system.

Software

Software OperatiX - 04 (optional). DAQ software specially designed in National Instrument™, LABVIEW™ environment to measure and calculate the results of the apparatus. The software is optional; a set of electronic sensors is included when the software is used. The software can be run in any Windows™ environment.

Scope of Delivery

Optional Accessories

Standards & Compliance

Ordering & Delivery

Frequently Asked Questions

Q: What is the Batch Distillation Column Apparatus OperatiX - 04 used for?
A: It is used to separate liquid mixtures of distinct, mutually soluble liquids via batch distillation, using ethanol and water as the recommended mixture.

Q: Can the system operate under vacuum?
A: Yes, vacuum mode is possible with a vacuum pump, reaching a final vacuum of 200mbar.

Q: What types of columns are available for this apparatus?
A: Optional columns include the Sieve tray column (OperatiX - 07), Packed Column (OperatiX - 15), Bubble cap tray column (OperatiX - 08), Valve tray column (OperatiX - 14), and Structured Packing Column (OperatiX - 09).

Q: Is data acquisition software available with this system?
A: Yes, Software OperatiX - 04 is available as an optional add-on, designed in National Instrument™ LABVIEW™ environment, and can run in any Windows™ environment.

Q: How is the reflux ratio adjusted?
A: The reflux ratio is adjusted using valves, with a measuring range of 0 to 100%.

Scientico India · Industrial Area, Ambala Cantt, Haryana 133001, IN
scienticoindia.com · +91 7015865225 · [email protected]