Scientico IndiaManufacturer & Exporter · Ambala · Since 1993
ISO 9001:2015CE MARKED60+ COUNTRIES

Building Management System Trainer | PolarX - 568

Category: Refrigeration and Air Conditioning  ·  Country of Origin: India

Product Overview

The Building Management System Trainer PolarX - 568 is a small lab scale model for studying intelligent building automation. This Building Management System Trainer covers climate, humidity, temperature, fluid, and pressure management using PID based digital controllers. Sensors supply input signals for temperature, humidity, pressure, and flow to an advanced intelligent controller. Simulated feedback signals, including a heater, simulated fluid flow, a humidifier, and an air blower, replace large scale physical components. The control panel is pre wired with quick connectors, and optional DAQ software (National Instrument™ LABVIEW™) is available for data measurement and calculation.

Building Management System Trainer | PolarX - 568
Request a QuoteWhatsApp +91 7015865225
[email protected]

Technical Specifications

Building Management System Trainer PolarX - 568: Technical Specifications

Specification Value
Product Name Building Management System Trainer
Model PolarX - 568
Power Supply 220V AC
Control Panel Type Pre wired type with input and output devices installed
Electrical Connections Quick connector type
Controller Type (all channels) PID based digital controllers

Technical Data

Temperature Controller

Parameter Value
Controller Type PID based digital Temperature Controller
Output Device Electric Heater
Signal Device PT-100 RTD or K Type Thermocouple for Temperature Sensing

Humidity Controller

Parameter Value
Controller Type PID based digital Humidity Controller
Output Device Ultrasonic Room Humidifier
Signal Device Humidity Sensor, 0 to 100% RH, analog output to Controller

Fluid Controller

Parameter Value
Controller Type PID based digital Proportional Controller for opening and closing of flow control valve
Output Device Flow Control Valve
Signal Device Flow Meter / Temperature Sensor for flow regulating

Pressure Controller

Parameter Value
Controller Type PID based digital Controller
Output Device Fan with damper to control the inlet damper opening
Feedback Signal Device Differential Pressure Sensor in small box (room model) with analog output signal

Control Panel

Parameter Value
Type Pre wired, input and output devices pre installed
Connections Quick connector for electrical connections
Power Supply 220V AC

Key Features

Key Features

Experiments

Using the Building Management System Trainer PolarX - 568, experiments can be performed for the following applications:

Construction and Design

The Building Management System Trainer PolarX - 568 is built as a small lab scale model of a real building management system. Different sensors are fitted on the trainer to supply input signals for temperature, humidity, pressure, flow, and access control. An advanced intelligent controller processes these input signals. Each controller manages its output based on programmable parameters. Instead of physical large scale components and output devices, the trainer uses simulated feedback signals. A heater simulates the heating output. Fluid flow is simulated as cold water to the evaporator. A humidifier simulates the humidity output. An air blower simulates the pressure output. The control panel is pre wired, with all input and output devices already installed. Quick connectors are provided for electrical connections. This design makes the Building Management System Trainer compact and ready for laboratory use.

Software

Software PolarX - 568 (optional)

DAQ software specially designed in National Instrument™ LABVIEW™ environment to measure and calculate the results of the apparatus. The software is optional. A set of electronic sensors is included when the software option is used. The software can be run on any Windows™ environment.

Scope of Delivery

Standards & Compliance

Ordering & Delivery

Frequently Asked Questions

Q1: What is the Building Management System Trainer PolarX - 568 used for?
A: It is used to demonstrate and experiment with intelligent building management functions including climate, humidity, temperature, fluid, pressure, and access control on a small lab scale model.

Q2: What type of controllers does the trainer use?
A: All controllers on the trainer, temperature, humidity, fluid, and pressure, are PID based digital controllers.

Q3: Does the trainer use real building scale components?
A: No. Instead of physical large scale components and output devices, the trainer uses simulated feedback signals such as a heater, simulated fluid flow, a humidifier, and an air blower.

Q4: Is the DAQ software included by default?
A: No. Software PolarX - 568 is optional. When the software is used, a set of electronic sensors is included.

Q5: What power supply does the trainer require?
A: The trainer operates on a 220V AC power supply.

Scientico India · Industrial Area, Ambala Cantt, Haryana 133001, IN
scienticoindia.com · +91 7015865225 · [email protected]