Changes of State in Refrigeration Circuit | PolarX - 512

Category: Refrigeration and Air Conditioning  ·  Country of Origin: India

Product Overview

The Changes of State in Refrigeration Circuit PolarX - 512 is a Demonstrative Refrigeration Study Unit that illustrates the key stages of a compression frigorific cycle. It uses a glass-realized condenser and evaporator to show condensation and evaporation phenomena directly. Compression work is performed by a piston-type hermetic compressor, with network water as the evaporating and condensing fluid and R141b as the cooling fluid. The unit features two digital thermometers, two flowmeters, two pressure gauges, and a full synoptic panel for continuous monitoring of all key parameters.

Changes of State in Refrigeration Circuit | PolarX - 512
Request a QuoteWhatsApp +91 7015865225
[email protected]

Technical Specifications

Changes of State in Refrigeration Circuit PolarX - 512, Technical Specifications

Specification Detail
Compressor Hermetic motor/compressor unit, piston type
Evaporator Water/R141b evaporator
Condenser Water/R141b condenser
Expansion Valve Manual isenthalpic expansion valve
Condenser Flow Meter Flow meter with control valve of the H2O delivery at the condenser
Evaporator Flow Meter Flow meter with control valve of the H2O delivery at the evaporator
Condensation Pressure Gauge Pressure gauge for condensation pressure
Evaporation Pressure Gauge Pressure gauge for evaporation pressure
Safety Switch Maximum pressure safety switch
Temperature Indicator Temperature digital indicator
Temperature Probes Type K thermocouple
Electrical Protection Magnetothermic differential switch, manual controls and protection fuses

Technical Data

General

Parameter Value
Capacity 538 kcal/h with evaporation -40°C
Compressor Power 270 W
Condenser Capacity 1200 cm3 approx.
Evaporator Capacity 1200 cm3 approx.
Water Consumption 200 l/h approx.
Water Supply Lab water supply

Suction Side (Low Pressure)

Parameter Value
Pressure -1 to 16 bar

Delivery Side (High Pressure)

Parameter Value
Pressure -1 to 25 bar

Pressure Safety Switch

Parameter Value
Location Suction Side and Delivery Side

Digital Multifunctional Power Meter

Parameter Value
Range of AC Volt 0 to 500 volts
Range of AC Ampere 0 to 40 Ampere

Evaporator Flow Rate

Parameter Value
Range 0 to 7 LPM

Condenser Flow Rate

Parameter Value
Range 0 to 7 LPM

Temperature Sensor

Parameter Value
Range -40°C to 400°C
Type K
Total 5

Key Features

Key Features

Experiments

Construction and Design

The Changes of State in Refrigeration Circuit PolarX - 512 is built around a front panel with a mimic diagram and integrated instrumentation. The condenser and evaporator are glass-realized, allowing direct visual observation of the cooling fluid. Compression work is carried out by a piston-type hermetic compressor. The evaporating and condensing fluid is network water. The cooling fluid is R141b. A manual micrometrical valve carries out the cooling gas isenthalpic expansion. Instrumentation is built into the actual cycle for continuous monitoring. Two digital instantaneous thermometers with switches read inlet and outlet temperatures. Two flowmeters read water flow rates during evaporation and condensation. Two pressure gauges read pressures during condensation and evaporation. A full synoptic panel completes the design for quick comprehension of the cycle.

Software

Software PolarX - 512 (optional)

DAQ software designed in National Instruments™ LabVIEW™ environment to measure and calculate the results of the apparatus. The software is optional. When the software is used, a set of electronic sensors is included. The software can be run on any Windows™ environment.

Scope of Delivery

Required for Operation

Optional Accessories

Standards & Compliance

Ordering & Delivery

Frequently Asked Questions

Q: What does the Changes of State in Refrigeration Circuit PolarX - 512 demonstrate?
A: It demonstrates the key stages of a compression frigorific cycle, including condensation and evaporation phenomena.

Q: What cooling fluid is used in this unit?
A: R141b, chosen for its good thermodynamic properties and high safety degree.

Q: What type of compressor does the unit use?
A: A piston-type hermetic compressor.

Q: How is temperature monitored on the unit?
A: Two digital instantaneous thermometers with switches show inlet and outlet temperatures.

Q: Is the PolarX - 512 software required to operate the unit?
A: No, the software is optional. A set of electronic sensors is included when the software is used.