The Commercial Refrigeration Training Unit PolarX - 604 features an air-cooled condensing unit with a hermetic compressor rated for high back pressure and high starting torque. This Commercial Refrigeration Training Unit includes a forced air evaporator with 5 FPI aluminium fins, a detachable insulated hood (100-watt heat load) for thermal performance testing, and an internally equalized thermostatic expansion valve. Pressure monitoring is handled by high and low pressure switches and gauges, alongside 4 Type-k temperature sensors. Optional LABVIEW-based DAQ software supports automated data measurement.

Commercial Refrigeration Training Unit PolarX - 604, Technical Specifications
| Component | Type / Detail |
|---|---|
| Condensing Unit | Air-cooled, high back pressure, high starting torque hermetic compressor |
| Service Valves | Suction and Discharge Service Valves |
| Gauge Connections | Gauge Manifold Connections |
| Motor Protection | Built in Motor Protector |
| Evaporator | Forced air, blow through type, 15-watt fan motor |
| Evaporator Casing | Powder coated galvanized sheet steel, removable front panel |
| Evaporator Coil | Internally grooved copper tube, aluminium fins at 5 FPI |
| Insulated Hood | Detachable, heat load 100 watts |
| Temperature Sensing | K type thermocouple |
| Expansion Valve | Internally equalized Thermostatic Expansion Valve |
| Filter Drier | Liquid Line Filter Drier |
| Heat Exchanger | Liquid-vapour type |
| Pressure Switches | High Pressure Switch, Low Pressure Switch |
| Pressure Gauges | High Pressure gauge and low pressure compound gauge |
| Base and Frame | Stainless steel base on a steel frame |
Technical Data
Condenser
| Parameter | Value |
|---|---|
| Type | Fan Cool, Continuous Tubing and External Finned |
Temperature Sensor
| Parameter | Value |
|---|---|
| Range | -40~400°C |
| Type | Type-k |
| Total | 4 |
Refrigerant Pressure Gauges
| Parameter | Value |
|---|---|
| Suction Side (low pressure gauge) | -1~16bar |
| Delivery Side (high pressure gauge) | -1~25bar |
Digital Multifunctional Power Meter
| Parameter | Value |
|---|---|
| Range of AC Volt | 0~500 volts |
| Range of AC Ampere | 0~40 Ampere |
Pressure Safety Switch
| Side | Value |
|---|---|
| Suction Side | Not specified |
| Delivery Side | Not specified |
Key Features
Construction and Design
The Commercial Refrigeration Training Unit PolarX - 604 uses an air-cooled condensing unit built around a hermetic compressor with high back pressure and high starting torque. The unit includes suction and discharge service valves, gauge manifold connections, and a built-in motor protector. The forced air, blow through evaporator features a powder coated galvanized sheet steel casing with a removable front panel, and its coil is constructed from internally grooved copper tube fitted with aluminium fins at 5 FPI. A detachable insulated hood applies a 100-watt heat load, monitored by a K type thermocouple. The system includes an internally equalized thermostatic expansion valve, liquid line filter drier, and liquid-vapour heat exchanger. High and low pressure switches, along with a high pressure gauge and low pressure compound gauge, provide pressure monitoring. The base is stainless steel, mounted on a steel frame.
Software
PolarX - 604 (optional). A DAQ software package, specially designed in National Instruments LABVIEW environment, measures and calculates the results of the apparatus. The software is optional. When the software is used, a set of electronic sensors is included. The software can be run on any Windows environment.
Scope of Delivery
Q: What type of compressor does the Commercial Refrigeration Training Unit PolarX - 604 use?
A: A hermetic compressor with high back pressure and high starting torque, part of an air-cooled condensing unit.
Q: How is the evaporator constructed?
A: The evaporator coil is made from internally grooved copper tube fitted with aluminium fins at 5 FPI, housed in a powder coated galvanized sheet steel casing with a removable front panel.
Q: How is thermal performance tested?
A: A detachable insulated hood applies a 100-watt heat load, monitored using a K type thermocouple and digital thermometer.
Q: What pressure monitoring components are included?
A: High and low pressure switches, along with a high pressure gauge and low pressure compound gauge.
Q: Is the DAQ software required to operate the unit?
A: No. The PolarX - 604 software is optional, and a set of electronic sensors is included when the software is used.