Scientico IndiaManufacturer & Exporter · Ambala · Since 1993
ISO 9001:2015CE MARKED60+ COUNTRIES

Cross Flow Heat Exchanger | ThermoFlux - 7078

Category: Thermodynamics Lab Equipment  ·  Country of Origin: India

Product Overview

The Cross Flow Heat Exchanger ThermoFlux - 7078 is a laboratory unit for investigating heat transfer by forced and free convection using three interchangeable heating elements: a pipe, a pipe bundle, and a finned pipe bundle. Each element is rated at 500 W with adjustable heating power and variable airflow up to 13 m³/min through a 120 x 120 mm vertical duct. Electronic sensors measure temperature (2x -100 to 400°C), power (0 to 500 W), and air velocity (0 to 10 m/s), with all values displayed digitally on the front panel. This cross flow heat exchanger calculates flow rate, Reynolds number, and Nusselt number, and supports optional PC data transfer with LabVIEW-based DAQ software.

Cross Flow Heat Exchanger | ThermoFlux - 7078
Request a QuoteWhatsApp +91 7015865225
[email protected]

Technical Specifications

Cross Flow Heat Exchanger ThermoFlux - 7078, Technical Specifications

Parameter Value
Flow Channel Cross-Section 120 x 120 mm
Radial Fan Max. Power Consumption 250 W
Radial Fan Max. Pressure Difference 430 Pa
Radial Fan Max. Flow Rate 13 m³/min
Temperature Measuring Range 2x -100 to 400°C
Power Measuring Range 0 to 500 W
Air Velocity Measuring Range 0 to 10 m/s

Technical Data

Flow Channel

Parameter Value
Cross-Section 120 x 120 mm

Radial Fan

Parameter Value
Max. Power Consumption 250 W
Max. Pressure Difference 430 Pa
Max. Flow Rate 13 m³/min

Heating Elements

Pipe

Parameter Value
Power 1x 500 W
Heating Surface 1x approx. 0.01 m²

Pipe Bundle

Parameter Value
Power 1x 500 W
Heating Surface 1x approx. 0.005 m²

Finned Pipe Bundle

Parameter Value
Power 1x 500 W
Heating Surface 1x approx. 0.014 m²

Measuring Ranges

Parameter Value
Temperature 2x -100 to 400°C
Power 0 to 500 W
Air Velocity 0 to 10 m/s

Key Features

Key Features


Experiments


Construction and Design

The Cross Flow Heat Exchanger ThermoFlux - 7078 is built around a vertical air duct as its primary structural element. A radial fan draws air through the duct and delivers a maximum flow rate of 13 m³/min at up to 430 Pa pressure difference. The duct cross-section measures 120 x 120 mm. Three interchangeable heater inserts are included: a single pipe, a pipe bundle, and a finned pipe bundle. Each insert is rated at 500 W. The pipe bundle insert can be positioned in different pipe rows to vary the cross flow heat exchanger flow arrangement during experiments. Electronic sensors integrated into the system measure temperature across two channels (range: -100 to 400°C), power (0 to 500 W), and air velocity (0 to 10 m/s). All sensor readings are shown on a digital display mounted on the front panel of the instrumentation unit. The unit also supports direct PC data transfer for further analysis.


Software

ThermoFlux - 7078 Software (Optional)


Scope of Delivery

Standards & Compliance

Ordering & Delivery

Frequently Asked Questions

 

Q1: What heating elements are included with the Cross Flow Heat Exchanger ThermoFlux - 7078?
Three interchangeable heating elements are included: a pipe, a pipe bundle, and a finned pipe bundle. Each operates at 500 W.

Q2: Can the airflow rate be adjusted during experiments?
Yes. The radial fan allows variable airflow, with a maximum flow rate of 13 m³/min and a maximum pressure difference of 430 Pa.

Q3: Is the software included as standard?
No. The ThermoFlux - 7078 DAQ software is optional. When selected, it includes the required electronic sensors and runs on any Windows operating system.

Q4: What parameters does the system calculate automatically?
The unit calculates flow rate, Reynolds number, and Nusselt number from sensor data. It can also display temperature-time relationships and the dependence of Nusselt number on Reynolds number graphically.

Q5: Can the pipe bundle be repositioned within the duct?
Yes. The heater insert for the pipe bundle can be positioned in different pipe rows within the duct to investigate the effect of flow position on heat transfer performance.

Scientico India · Industrial Area, Ambala Cantt, Haryana 133001, IN