A CE-certified apparatus for experimental study of deflection of simply supported and cantilever beams under various loading conditions, manufactured by Scientico India to ISO 9001:2015 standards. Supplied with calibration certificate, operation manual, and complete export documentation. Designed for Strength of Materials laboratories in engineering colleges and technical institutions.

| Parameter | Details |
|---|---|
| Model | FortiTestX 06 |
| Unit Type | Benchtop, anodized aluminum section frame |
| Beam Materials | Stainless steel, brass, aluminum, mild steel, copper |
| Beam Cross-Sections (all materials) | 19 x 3 mm, 19 x 5 mm, 19 x 6 mm |
| Total Beam Sections Supplied | 15 (3 cross-sections × 5 materials) |
| Articulated Supports with Force Gauge | 3; height-adjustable; range 0–100 N; least count 0.5 N |
| Supports with Clamp Fixing | 2 |
| Dial Gauges | 3 |
| Weight Sets | 4 sets with adjustable riders |
| Weights Supplied | 4 × 0.5 N hangers, 8 × 0.5 N, 8 × 1 N, 8 × 2 N, 8 × 5 N |
| Measuring Scale | 1 m length |
| Optional Software | FT-06, LabVIEW-based data logging; Windows compatible |
| Scope of Delivery | 1 experimental unit, 1 storage unit, 3 dial gauges, 4 weight sets, 3 articulated supports with force gauges, 2 supports for clamping, 5 beam sets, 1 manual, 1 measuring scale (1 m) |
Key Features
Applications
Construction and System Design
The apparatus is built within a rigid anodized aluminum section frame that provides a stable and consistent reference plane for all beam and support configurations. The three articulated supports are height-adjustable via fine adjustment mechanisms and incorporate integrated force gauges with zeroing, peak, and tracking functions, allowing support reactions to be read directly without external instrumentation. The clamp-fixing supports establish fixed-end boundary conditions for cantilever and other statically indeterminate configurations. Beam sections are interchangeable and standardized to a width of 19 mm across all five materials, with thickness varying across the three supplied cross-sections. The adjustable riders on the weight sets allow uniform load distribution to be simulated along defined spans. All experimental components are stored in a dedicated storage system within the frame, keeping the apparatus organised and ready for repeated laboratory use.
Export and Supply Capability
SCIENTICO manufactures and supplies the FortiTestX 06 Deflection of Beam Apparatus to engineering institutions and laboratory equipment distributors internationally. The unit is packaged for safe transit and is suitable for supply to universities, civil and mechanical engineering departments, and technical training institutes across export markets. Customization of beam materials, cross-sections, or software integration is available upon inquiry.
1. What beam configurations can be tested using the FortiTestX 06?
The apparatus supports cantilever beams, single-span beams, dual-span beams, and triple-span beams under both statically determinate and statically indeterminate conditions. End conditions can be varied using the interchangeable articulated supports and clamp-fixing supports.
2. How many beam sections are supplied and what materials are available?
Fifteen beam sections are supplied across five materials, stainless steel, brass, aluminum, mild steel, and copper, each available in three cross-sections: 19 x 3 mm, 19 x 5 mm, and 19 x 6 mm. This range enables direct comparison of the effect of elastic modulus and cross-sectional geometry on beam deflection.
3. How are support reactions measured on the FortiTestX 06?
Three articulated supports are fitted with built-in force gauges with a measurement range of 0 to 100 N and a least count of 0.5 N. The gauges feature zeroing, peak hold, and tracking functions and provide direct support reaction readings without the need for external instrumentation.
4. Is software available for the FortiTestX 06?
Yes. Optional LabVIEW-based software is available for automated data logging and results processing. It is compatible with any Windows operating system and is designed specifically for use with the FortiTestX 06 experimental setup.
5. What analytical methods can be verified using the FortiTestX 06?
The apparatus supports experimental verification of results obtained from differential equation analysis, the Area Moment Method, the principle of virtual work, Maxwell-Betti reciprocal theorem coefficients, and influence line determination using both arithmetic methods and the qualitative Muller-Breslau force method.