The Educational Training Steam Boiler (100kg/h) ThermoFlux - 7107 is a package-type, vertical 3-pass water tube boiler designed for engineering thermodynamics education. This training steam boiler generates up to 100 kg/h of steam at 10 bar operating pressure, powered by a LAMBORGHINI ITALY light oil force draft burner. A fully instrumented feed water system, shell-and-tube condenser, digital and analog measuring instruments, and a comprehensive safety circuit are integrated on a single skid. The apparatus supports ten structured experiments covering boiler construction, vapor pressure curves, pressure-temperature relationships, heat transfer, and condenser performance.

Educational Training Steam Boiler (100kg/h) ThermoFlux - 7107, Technical Specifications
| Parameter | Value |
|---|---|
| Model | ThermoFlux - 7107 |
| Boiler Type | Water Tube |
| Installation | Vertical |
| Number of Passes | Minimum 3 pass |
| Steam Output Capacity | Approx. 100 kg/h |
| Operating Pressure | 10 bar (10.2 kg/cm²) |
| Test Pressure (Tubing) | 25 bar (25.50 kg/cm²) hydraulic |
| Test Pressure (Steam Tank) | 16 bar (16.25 kg/cm²) hydraulic |
| Tube Material | High Pressure Boiler Grade Seamless Mild Steel |
| Shell Material | High Pressure Boiler Grade Steel Sheet |
| Steam Tank Material | High Pressure Boiler Grade Steel |
| Insulation | 2" to 3" thick ceramic wool |
| Burner Make | LAMBORGHINI ITALY |
| Burner Type | Force Draft Built-in Atomizer (standard) |
| Fuel Type | Light oil: diesel, kerosene, jet fuel, and other light oils |
| Optional Burner | Gas type pre-mixed burner (specify at order) |
| Burner Control | ON/OFF, controlled by temperature controller |
| Steam Outlet | Steam separator + DN25 valve |
| Condenser Type | Shell and tube |
| Feed Water Pump Type | Centrifugal, high pressure |
| Pump Control | Manual or automatic, user selectable |
| Level Control Type | Water dip electrode, two-point (start/stop) |
| Water Level Indication | Sight glass + level sensors |
| High Pressure Switch 1 | Set at 9 bar |
| High Pressure Switch 2 | Set at 10 bar |
| High Pressure Safety (Mechanical) | Set at 11 bar / 160 PSI |
| Digital Temperature Controller | Max setting 180°C, user configurable |
| Over-Temperature Safety | Bimetallic type |
| Mounting | Single skid, package type |
| Scope of Delivery | 1 experimental unit, 1 instructional manual |
| Parameter | Value |
|---|---|
| Boiler Type | Water Tube |
| Installation | Vertical |
| Tube Material | High Pressure Boiler Grade Seamless Mild Steel |
| Shell Material | High Pressure Boiler Grade Steel Sheet |
| Steam Tank Material | High Pressure Boiler Grade Steel |
| Number of Passes | Minimum 3 pass |
| Operating Pressure | 10 bar (10.2 kg/cm²) |
| Test Pressure (Tubing) | 25 bar (25.50 kg/cm²) hydraulic |
| Test Pressure (Steam Tank) | 16 bar (16.25 kg/cm²) hydraulic |
| Insulation | 2" to 3" thick ceramic wool |
| Parameter | Value |
|---|---|
| Burner Make | LAMBORGHINI ITALY |
| Burner Type | Force Draft Built-in Atomizer |
| Fuel Compatibility | Diesel, kerosene, jet fuel, and other light oils |
| Control Type | ON/OFF, temperature controller governed |
| Flame Protection | Built-in, state-of-the-art boiler burner |
| Optional Burner | Gas type pre-mixed burner (specify at order) |
| Parameter | Value |
|---|---|
| High Pressure Switch 1 | Set at 9 bar |
| High Pressure Switch 2 | Set at 10 bar |
| Mechanical High Pressure Safety | Set at 11 bar / 160 PSI |
| Digital Temperature Controller | 1st controller, max 180°C, user configurable |
| Over-Temperature Safety | 2nd, bimetallic type |
| Safety Valve | Included |
| Pressure Gauge | Included |
| Parameter | Value |
|---|---|
| Level Indicator Type | Water dip electrode, two-point (start/stop) |
| Sight Glass | Included |
| Level Sensors | Included |
| Level Controller | Included |
| Parameter | Value |
|---|---|
| Filter | Two-stage resin filter for public water |
| Water Softener | Activated carbon type with manual charging and service valves |
| Feed Water Pressure Gauge | Included |
| Soft Water Tank | Stainless steel |
| Water Meter | With totalizer function |
| Feed Water Pump Type | Centrifugal, high pressure |
| Pump Control Mode | Manual or automatic, user selectable, controlled by water level controller |
| Parameter | Value |
|---|---|
| Steam Outlet Port | Steam separator + DN25 valve |
| Integration | Compatible with external hardware or built-in condenser |
| Parameter | Value |
|---|---|
| Smoke Out Port | Boiler stack for laboratory smoke extraction |
| Parameter | Value |
|---|---|
| Condenser Type | Shell and tube |
| Condensate Path | Tubes |
| Cooling Water Path | Shell |
| Construction | Thick-walled cylinder with water-cooled tube coil |
| Parameter | Value |
|---|---|
| Fuel Tank | Included |
| Fuel Flow Meter | Digital readout |
| Instrument | Display Type |
|---|---|
| Feed Water Inlet Temperature | Digital |
| Steam Outlet / Boiler Temperature | Digital |
| Boiler Pressure Gauge | Analog |
| Instrument | Display / Type |
|---|---|
| Condensate Inlet (Steam In) Temperature Sensor | Digital |
| Condensate Outlet (Steam Out) Temperature Sensor | Digital |
| Condenser Cooling Water Flow Rate | Analog rotameter |
| Condensate Measurement | Manual, measuring cylinder |
Key Features
Experiments
Construction and Design
The Educational Training Steam Boiler (100kg/h) ThermoFlux - 7107 is constructed as a vertical, 3-pass water tube boiler mounted on a single skid in package configuration. Water is contained within high-pressure boiler-grade seamless mild steel tubes. The shell is fabricated from high-pressure boiler-grade steel sheet, and the steam tank is high-pressure boiler-grade steel. The entire boiler is insulated with 2" to 3" thick ceramic wool to minimize heat loss.
The LAMBORGHINI ITALY burner is positioned centrally within the circular tube bundle. Heat from the burner transfers to the water inside the tubes, and the hot water self-circulates through the 3-pass arrangement. A boiler stack handles smoke extraction for safe indoor laboratory use.
The steam outlet port incorporates a steam separator and a DN25 valve. The condenser is a thick-walled shell-and-tube cylinder, with condensate flowing through the tubes and cooling water on the shell side. Both the training steam boiler and condenser units are arranged together on the skid for a compact, single-installation footprint.
The feed water side includes a two-stage resin filter, an activated carbon water softener with manual service valves, a stainless steel soft water tank, a water meter with totalizer, and a centrifugal high-pressure pump. Safety architecture includes two high-pressure switches, one mechanical pressure relief valve, a digital temperature controller, a bimetallic over-temperature device, a safety valve, and a pressure gauge. Level control uses electrode-based two-point switching supported by a sight glass.
Scope of Delivery
Optional Accessories
Q1: What fuel types are compatible with the standard burner on the ThermoFlux - 7107?
The standard LAMBORGHINI ITALY force draft burner supports light oils, including diesel, kerosene, jet fuel, and other comparable light oil fuels.
Q2: Can a gas burner be used with this training steam boiler?
Yes, an optional gas type pre-mixed burner is available. It must be specified at the time of order. Only one burner can be installed and used with the boiler.
Q3: What is the maximum safe operating pressure of the ThermoFlux - 7107?
The operating pressure is 10 bar (10.2 kg/cm²). The mechanical high-pressure safety is set at 11 bar / 160 PSI. The tubing is hydraulically tested to 25 bar (25.50 kg/cm²) and the steam tank to 16 bar (16.25 kg/cm²).
Q4: How does the feed water supply system work?
Public water passes through a two-stage resin filter and an activated carbon water softener before entering a stainless steel soft water tank. A centrifugal high-pressure pump delivers soft water to the boiler, controlled in either manual or automatic mode by the water level controller. A water meter with totalizer tracks total water supply for steam calculations.
Q5: What measurements can students take on the condenser?
Students can record condensate inlet and outlet temperatures using digital sensors, monitor cooling water flow rate using the analog rotameter, and measure condensate volume manually with a measuring cylinder. These readings support experiments on heat transfer, condenser efficiency, and flow measurement.