A CE-certified precision laboratory apparatus for engineering experimentation and technical education, manufactured by Scientico India to ISO 9001:2015 standards. Supplied with calibration certificate, operation manual, and complete export documentation. Designed for Fluid Mechanics laboratories in engineering colleges and technical institutions.

| Parameter | Specification |
|---|---|
| Water Manometer Range | 0 to 500 mm |
| Water Manometer Slope (Adjustable) | 10% to 100% |
| Mercury Manometer Range | 0 to 500 mm |
| Bourdon Gauge Range | 0 to 4 kg/cm² |
| Aneroid Barometer Range | 954 to 1073 mbar |
| Hygrometer Range | 10 to 100% RH |
| Thermometer Range | -10 to 110°C and 0 to 300°C |
| Hydrometer Range | 0.7 to 2.0 (in multiple ranges) |
| Specific Gravity Bottle Capacity | 0 to 25 ml |
| Beakers, Containers and Pipette | 2 units each |
| Capillary Viscometer Range | 2 to 10 cSt |
| Falling Sphere Viscometer Range | 10 to 850 St |
| Circulation Pump Flow Rate | 10 LPM @ 2 m head |
| Triple Beam Balance Range | 0 to 2610 g |
| Triple Beam Balance Accuracy | ±0.1 g |
| Vernier Hook Gauge Range | 0 to 150 mm |
| Vernier Hook Gauge Accuracy | ±0.05 mm |
| Capillary Tubes | 3 to 5 units |
| Storage Tank Capacity | 100 L |
| Dead Weight Pressure Tester | Included |
| Hydrostatic Pressure Apparatus | Included |
| Metacentric Height Apparatus | Included |
| Archimedes' Apparatus | Included |
| Pascal's Apparatus | Included |
| Capillary Attraction Plates | Included |
| Parameter | Value |
|---|---|
| Diameter | 6" or 150 mm |
| Bourdon Tube Pressure Range | 0 to 4 bar |
| Least Count | 0.1 bar / 1 PSI |
| Scale | PSI / bar |
| Parameter | Value |
|---|---|
| Water Tank Content | 1.8 L |
| Water Tank Inclination Angle | 0 to 90° |
| Water Tank Scale | 0 to 250 mm |
| Lever Arm Maximum Length | 0 to 250 mm |
| Balancing Weight | 250 g |
| Sliding Weight | 250 g |
| Parameter | Value |
|---|---|
| Water Tank Material | Molded plastic |
| Water Tank Dimensions | nominally 600 mm x 400 mm x 120 mm |
| Floating Pontoon Dimensions | 360 mm x 203 mm x 76 mm |
| Angular Tilt of Pontoon | nominally 15° each side of vertical center line |
| Working Height of Sail | 240 mm |
| Adjustable Sail Weight | 525 g (approx.) |
| Parameter | Value |
|---|---|
| Parallel Vessel Inside Diameter | 26 mm |
| Conical Vessel Inside Diameter | 26 to 101 mm (at top) |
| Tapered Vessel Inside Diameter | 26 mm to 9 mm (at top) |
| Diameter at Diaphragm | 56 mm |
| Maximum Depth of Water | 228 mm (to top of vessels) |
Key Features
Experiments
Construction and Design
The FluidoSurge-X 212 is built as a mobile, self-contained bench unit integrating all experimental apparatus within a single structure requiring no external laboratory services. The bench houses a 100 L storage tank and a circulation pump rated at 10 LPM at 2 m head. The metacentric height apparatus uses a molded plastic water tank nominally measuring 600 mm x 400 mm x 120 mm, paired with a floating pontoon of 360 mm x 203 mm x 76 mm providing up to 15° angular tilt on either side of the vertical center line. The hydrostatic pressure apparatus includes a 1.8 L water tank adjustable from 0 to 90° inclination with a 0 to 250 mm scale, and a lever arm adjustable from 0 to 250 mm with two 250 g weights. Pascal's apparatus incorporates three distinct vessel profiles, parallel (26 mm ID), conical (26 to 101 mm ID at top), and tapered (26 mm to 9 mm ID at top), with a diaphragm diameter of 56 mm and maximum water depth of 228 mm. The bench includes 3 to 5 capillary tubes, capillary attraction plates, and a vernier hook gauge measuring to ±0.05 mm accuracy.
Scope of Delivery
Q1. Is this bench independent of laboratory water supply?
Yes, the bench is self contained and includes its own storage tank and circulation pump.
Q2. What type of fluids can be studied using this bench?
The apparatus is designed for experiments on Newtonian fluids using water and compatible laboratory liquids.
Q3. Are hydrostatic pressure and metacentric height experiments included?
Yes, dedicated hydrostatic pressure and metacentric height apparatus are included.
Q4. Can pressure gauges be calibrated using this bench?
Yes, a dead weight pressure calibrator is included for gauge calibration experiments.
Q5. Is the bench suitable for undergraduate laboratories?
Yes, it is designed for structured teaching in undergraduate and diploma level fluid mechanics labs.