A CE-certified precision laboratory apparatus for engineering experimentation and technical education, manufactured by Scientico India to ISO 9001:2015 standards. Supplied with calibration certificate, operation manual, and complete export documentation. Designed for Fluid Mechanics laboratories in engineering colleges and technical institutions.

| Parameter | Specification |
|---|---|
| Apparatus Type | Pipe network flow analysis unit |
| Mounting | Freestanding support frame |
| Pipe Material | PVC |
| Pipe Length | 0.7 m each |
| Pipe Internal Diameters | 1 × 9.5 mm, 2 × 14 mm, 1 × 12.7 mm, 1 × 18.5 mm |
| Pipe Connections | Union fittings with O-ring seals |
| Flow Control | Individual isolating valves |
| Pressure Measurement | U-tube manometer connections |
| Discharge Measurement | Volumetric hydraulic bench |
| Water Supply | Hydraulic bench or laboratory tap water |
| Sump Tank Capacity | 175 L |
Key Features
Modular pipe network for series, parallel, and mixed configurations
Freestanding frame suitable for independent laboratory setup
Tool-free pipe repositioning using union and O-ring connections
Individual flow control at network inlets and outlets
Self-sealing quick-release fittings for pressure measurement
Compatible with volumetric measurement using a hydraulic bench
Designed for repeated reconfiguration without system drainage
Applications
Fluid mechanics laboratory experiments
Study of head loss versus discharge in pipes
Analysis of flow distribution in pipe networks
Investigation of parallel and series pipe characteristics
Demonstration of ring main behavior and flow redistribution
Construction & Design Details
The apparatus uses rigid PVC pipes mounted on a stable freestanding support frame. Pipes are connected using unions with O-ring seals, allowing rapid rearrangement of network layouts without tools. Reinforced flexible hoses with quick-release fittings connect the network to the water source. Strategic pressure tapping points with self-sealing connectors enable fast attachment of manometers for differential pressure measurement.
Experiments
Measurement of head loss versus discharge for different pipe diameters
Study of flow through series pipe networks
Study of flow through parallel pipe networks
Investigation of flow in mixed and interconnected pipe systems
Effect of doubling pipes on flow rate
Analysis of ring main behavior under changing supply and off-take conditions
Required for Operation
Hydraulic bench with closed water circuit or laboratory water connection
Sump tank with approximately 175 L capacity
Standard Scope of Delivery
1 experimental module
Assorted flexible pipes of different diameters
1 instruction manual
Optional Accessories
U-tube manometer up to 1 m with 1 mm graduation
Water manometer with hand pump
Mercury manometer
Export & Supply Capability
SCIENTICO manufactures the Pipe Network Apparatus FluidoSurge-X 228 for engineering colleges, technical universities, and training laboratories. The equipment is suitable for domestic and international supply. Export packing and documentation are provided according to customer and destination requirements.
Q1. What types of pipe configurations can be created with this apparatus?
Series, parallel, mixed networks, and ring main configurations can be assembled.
Q2. Can the network be reconfigured without draining the system?
Yes. Union fittings with O-ring seals allow repositioning without draining.
Q3. How is flow rate measured in the system?
Flow leaving the network is measured using a volumetric hydraulic bench.
Q4. How are pressure losses measured?
Differential pressures are measured using manometers connected via self-sealing quick-release fittings.
Q5. Is a hydraulic bench included with the apparatus?
No. A hydraulic bench or laboratory water supply is required for operation.