Scientico IndiaManufacturer & Exporter · Ambala · Since 1993
ISO 9001:2015CE MARKED60+ COUNTRIES

Pressure Measurement Bench | ThermoFlux – 7015

Category: Thermodynamics Lab Equipment  ·  Country of Origin: India

Product Overview

The Pressure Measurement Bench ThermoFlux – 7015 is a freestanding laboratory unit combining a five-instrument manometer panel with an integrated Dead Weight Pressure Calibrator for comprehensive pressure measurement and calibration training. This Pressure Measurement Bench covers U-tube, inclined tube, and Bourdon tube manometry alongside digital pressure transmission (0–4 bar), with gauge pressure and vacuum measurement capability. The dead weight calibrator (piston area 254 × 10⁻⁶ m², ancillary masses up to 4 × 1 kg) produces traceable, reproducible calibration pressures transferred hydraulically to the gauge under test. Optional ThermoFlux – 7015 LabVIEW-based DAQ software with electronic sensors is available for Windows-based automated data acquisition.

Pressure Measurement Bench | ThermoFlux – 7015
Request a QuoteWhatsApp +91 7015865225
[email protected]

Technical Specifications

Pressure Measurement Bench ThermoFlux – 7015, Technical Specifications

Parameter Detail
Product Name Pressure Measurement Bench
Model ThermoFlux – 7015
Type Freestanding manometer panel with dead weight calibrator
Bourdon Tube Manometer (positive) 0 to 100 mbar
Bourdon Tube Manometer (vacuum) –100 to 0 mbar
U-Tube Manometer 0 to 500 mm WC
Inclined Tube Manometer 0 to 500 mm WC
Digital Pressure Transmitter 0 to 4 bar, with display
Test Pressure Generation Plastic syringe and/or hand pump (millibar range)
Dead Weight Tester Diameter 6 inch / 150 mm
Bourdon Tube Pressure Range (Dead Weight Tester) 0 to 4 kg/cm², transparent construction
Piston Cross-Sectional Area 254 × 10⁻⁶ m²
Mass of Piston 0.5 kg
Ancillary Masses 1 × 0.2 kg, 2 × 0.5 kg, 4 × 1 kg
Hydraulic Medium Hydraulic oil
Software (Optional) ThermoFlux – 7015 DAQ software, LabVIEW-based, Windows compatible

Technical Data

Manometer Panel, Instruments

Instrument Range
Bourdon Tube Manometer (gauge pressure) 0 to 100 mbar
Bourdon Tube Manometer (vacuum) –100 to 0 mbar
U-Tube Manometer 0 to 500 mm WC
Inclined Tube Manometer 0 to 500 mm WC
Digital Pressure Transmitter with Display 0 to 4 bar

Dead Weight Pressure Calibrator

Parameter Value
Tester Diameter 6 inch / 150 mm
Bourdon Tube Pressure Range 0 to 4 kg/cm² (transparent construction)
Piston Cross-Sectional Area 254 × 10⁻⁶ m²
Mass of Piston 0.5 kg
Ancillary Masses 1 × 0.2 kg, 2 × 0.5 kg, 4 × 1 kg
Hydraulic Medium Hydraulic oil
Levelling Adjustable levelling screws

Key Features

Key Features

  • Complete Pressure Measurement Bench: Integrates five instrument types, U-tube, inclined tube, two Bourdon tube dial manometers, and a digital pressure transmitter, on a single panel
  • Gauge pressure and vacuum measurement: Bourdon tube ranges of 0 to 100 mbar (positive) and –100 to 0 mbar (vacuum) on the same panel
  • U-tube manometer: 0 to 500 mm WC range for direct liquid-column pressure reading
  • Inclined tube manometer: 0 to 500 mm WC range for enhanced resolution at low differential pressures
  • Digital pressure transmitter: 0 to 4 bar range with integrated display for electronic reference measurement
  • Flexible interconnection: All manometers can be combined using connecting hoses for cross-comparison
  • Test pressure generation: Supplied plastic syringe and/or hand pump generates pressures in the millibar range
  • Dead Weight Pressure Calibrator: Precision-machined piston and cylinder assembly (254 × 10⁻⁶ m² piston area, 0.5 kg piston mass) for traceable calibration of Bourdon tube and dial manometers
  • Defined calibration pressures: Ancillary masses (1 × 0.2 kg, 2 × 0.5 kg, 4 × 1 kg) produce reproducible test pressures via force/area ratio
  • Transparent Bourdon gauge construction: Allows direct observation of internal Bourdon tube mechanism during calibration (0 to 4 kg/cm²)
  • Error curve generation: Piston rotation minimises friction; gauge readings compared against known pressures to plot instrument error curves
  • Optional DAQ software: ThermoFlux – 7015 LabVIEW-based software for automated data acquisition; Windows compatible

Experiments

  • Familiarisation with different pressure measurement methods
  • Function of a Bourdon tube manometer
  • Pressure measurement with U-tube and Bourdon tube manometers
  • Calibration of mechanical manometers

Construction and Design

The Pressure Measurement Bench ThermoFlux – 7015 is constructed as a freestanding panel unit housing all manometric instruments, connecting infrastructure, and calibration equipment in a single assembly. The manometer panel mounts two tube-type manometers (U-tube and inclined tube, both 0–500 mm WC), two dial-type Bourdon tube manometers (0–100 mbar and –100–0 mbar), and a digital pressure transmitter (0–4 bar) with integrated display. All instruments are interconnectable via flexible hoses, enabling simultaneous multi-instrument comparison under identical applied test pressures. The plastic syringe and hand pump interface directly with the hose network to generate millibar-range test pressures without auxiliary equipment.

The Dead Weight Pressure Calibrator section of this Pressure Measurement Bench comprises a precision-machined piston and cylinder assembly mounted on levelling screws to ensure vertical alignment during operation. Hydraulic oil transfers the force applied by the weighted piston (piston area: 254 × 10⁻⁶ m²; piston mass: 0.5 kg) to the Bourdon tube pressure gauge under test. The piston rod is rotated during loading to eliminate static friction effects and ensure pressure accuracy. The supplied ancillary masses (1 × 0.2 kg, 2 × 0.5 kg, 4 × 1 kg) allow stepped calibration across the gauge's working range. The calibration Bourdon gauge features transparent construction for internal mechanism observation. The optional LabVIEW-based DAQ software integrates with an electronic sensor set for automated measurement and result calculation under Windows environments.


Software

ThermoFlux – 7015 DAQ Software (Optional)

  • Developed in National Instruments™ LabVIEW™ environment
  • Measures and calculates experimental results from the apparatus
  • Compatible with all Windows™ operating systems
  • When the software option is selected, a set of electronic sensors is included

Scope of Delivery

  • 1 × Experimental unit
  • 1 × Instruction manual

Standards & Compliance

Ordering & Delivery

Frequently Asked Questions

Q1. What pressure measurement instruments are included on the manometer panel?
The panel includes a U-tube manometer (0–500 mm WC), an inclined tube manometer (0–500 mm WC), a positive-range Bourdon tube dial manometer (0–100 mbar), a vacuum-range Bourdon tube dial manometer (–100–0 mbar), and a digital pressure transmitter with display (0–4 bar).

Q2. How are test pressures generated on the ThermoFlux – 7015 Pressure Measurement Bench?
Test pressures in the millibar range are generated using the supplied plastic syringe and/or hand pump, which connect to the manometer panel via flexible hoses.

Q3. What is the purpose of the Dead Weight Pressure Calibrator?
The Dead Weight Pressure Calibrator generates a precisely defined, reproducible test pressure by loading the piston with known masses. The pressure (force ÷ piston area) is applied hydraulically to the gauge under calibration, allowing its readings to be verified and an error curve to be drawn.

Q4. What ancillary masses are supplied with the Dead Weight Pressure Calibrator?
The following masses are supplied: 1 × 0.2 kg, 2 × 0.5 kg, and 4 × 1 kg, in addition to the 0.5 kg piston mass.

Q5. Can the Pressure Measurement Bench be used without the optional DAQ software?
Yes. All four experiments can be performed manually using the panel instruments, syringe, hand pump, and dead weight calibrator. The ThermoFlux – 7015 DAQ software is an optional add-on for computerised data acquisition.

Scientico India · Industrial Area, Ambala Cantt, Haryana 133001, IN
scienticoindia.com · +91 7015865225 · [email protected]