A CE-certified apparatus for measuring surface emissivity and verifying the Stefan-Boltzmann law of thermal radiation, manufactured by Scientico India to ISO 9001:2015 standards. Supplied with calibration certificate, operation manual, and complete export documentation. Designed for Thermodynamics Lab Equipment laboratories in engineering colleges and technical institutions.

Thermal and Light Radiation ThermoFlux – 7031, Technical Specifications
| Parameter | Detail |
|---|---|
| Product Name | Thermal and Light Radiation |
| Model | ThermoFlux – 7031 |
| Track Orientation | Horizontal, with front and rear distance scales |
| Heat Source | Electrically heated aluminium plate, matt black finish |
| Light Source | 60 W bulb, well-distributed light output |
| Radiant Power Control | Adjustable, thermal radiator and light source |
| Heat Radiation Detector | Radiometer with digital readout |
| Light Measurement | Lux meter with digital readout |
| Target Plates | Three types: polished, grey, matt black |
| Target Plate Sensors | Bolt-on temperature sensor on each plate |
| Temperature Display | Control panel display for all three target plate temperatures |
| Accessories | Aperture plate (two vertical metal plates), set of light filters |
| Detector Mounting | Clamped stands, variable distance positioning |
| Software (Optional) | ThermoFlux – 7031 DAQ software, LabVIEW-based, Windows compatible |
Technical Data
Light Source
| Parameter | Detail |
|---|---|
| Type | Bulb |
| Power Rating | 60 W |
| Output | Well-distributed light |
Heated Plate (Radiation Source)
| Parameter | Detail |
|---|---|
| Material | Aluminium |
| Finish | Matt black |
| Type | Electrically heated |
Target Plates
| Plate Type | Temperature Sensor |
|---|---|
| Polished | Bolt-on temperature sensor |
| Grey | Bolt-on temperature sensor |
| Matt Black | Bolt-on temperature sensor |
Key Features
Experiments
Construction and Design
The Thermal and Light Radiation ThermoFlux – 7031 is constructed around a horizontal track fitted at one end with interchangeable heat radiation and light source assemblies. The heat radiation source is an electrically heated aluminium plate with matt black finish; the light source is a 60 W bulb configured for well-distributed output. Both sources have adjustable radiant power output. Distance scales are mounted on both the front and back of the track, enabling precise source-to-detector distance measurement throughout all Thermal and Light Radiation experiments. The radiometer and lux meter mount on clamped stands and are positionable at variable distances along the track. Three target plates, polished, grey, and matt black, each carry a bolt-on temperature sensor; their temperatures are displayed simultaneously on the control panel. An aperture plate (two vertically oriented metal plates) and a set of light filters complete the accessory range. All detector accessories clamp to stands for stable, repeatable positioning. Output from both the heat radiation detector and the lux meter is presented on dedicated digital readouts. The optional LabVIEW-based DAQ software interfaces with an included electronic sensor set for automated measurement and result calculation under Windows environments.
Software
ThermoFlux – 7031 DAQ Software (Optional)
Scope of Delivery
Q1. What radiation sources are included with the ThermoFlux – 7031?
The apparatus includes two sources: an electrically heated matt black aluminium plate as the thermal radiator, and a 60 W bulb as the light source. Both have adjustable radiant power output.
Q2. What are the three target plate types supplied, and how are their temperatures measured?
The three target plates are polished, grey, and matt black. Each carries a bolt-on temperature sensor; all three temperatures are displayed simultaneously on the control panel.
Q3. Which radiation laws can be verified using this Thermal and Light Radiation apparatus?
The unit supports experimental verification of the Inverse Square Law (heat and light), the Stefan-Boltzmann Law, Kirchhoff's Law, Lambert's Law of Absorption, and area factor (view factor) relationships.
Q4. How are source-to-detector distances measured on the ThermoFlux – 7031?
Distance scales are mounted on both the front and back of the horizontal track, enabling accurate and repeatable measurement of the distance between the radiation source and the detector at any position along the track.
Q5. Can the Thermal and Light Radiation apparatus be used without the optional DAQ software?
Yes. All experiments can be conducted manually using the supplied radiometer, lux meter, and control panel digital readouts. The ThermoFlux – 7031 DAQ software is an optional add-on for automated data acquisition and result calculation.