🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
Established 1993 Model-Specific Specifications Manufacturer-Direct Enquiries International Quotations Destination-Based Delivery Terms

Wetted Wall Gas Absorption Column | ReaktiLabX 16

Wetted Wall Gas Absorption Column ReaktiLabX 16 determines gas/liquid mass transfer coefficients used to design absorption towers. This wetted wall gas absorption column studies oxygen uptake into deoxygenated water prepared by nitrogen sparging, using a 900mm glass wetted wall column and a 1570mm clear acrylic deoxygenating column. Liquid film mass transfer coefficients can be calculated at different water mass flow rates. An oxygen meter measures saturation, concentration and temperature with automatic compensation.

The Wetted Wall Gas Absorption Column ReaktiLabX 16 is a bench-scale unit used to determine gas/liquid mass transfer coefficients, which are crucial for estimating the design of absorption towers. This wetted wall gas absorption column investigates the uptake of oxygen into deoxygenated water prepared by nitrogen sparging. It demonstrates controlled liquid film absorption.

Product Overview

The Wetted Wall Gas Absorption Column ReaktiLabX 16 provides coefficients that form the foundation for correlations used to create packed towers. Deoxygenated water is prepared by nitrogen sparging. Different water mass flow rates can be used to calculate the liquid film mass transfer coefficient. This wetted wall gas absorption column serves as a practical demonstration of controlled liquid film absorption for laboratory study.

Wetted Wall Gas Absorption Column ReaktiLabX 16 — Technical Specifications

Parameter Value
Wetted Wall Column Height 900mm
Wetted Wall Column Internal Diameter 32mm
Wetted Wall Column Material Glass
Deoxygenating Column Height 1570mm
Deoxygenating Column Internal Diameter 26mm
Deoxygenating Column Material Clear acrylic
Deoxygenating Column Range 600~5,000 ml/min
Water Flowmeter Range 1~7 l/min
Air Range 0.1~1m3/h
Deoxygenator Feed Pump 20 l/min @ 2m head
Absorption Column Feed Pump 10 l/min @ 1m head
Air Feed Pump 24 l/min @ 1 kg/cm2
Sump Tank Capacity Approx 40l
Oxygen Meter, Saturation Range 0-199.9%
Oxygen Meter, Saturation Accuracy ± 0.5%
Oxygen Meter, Saturation Resolution 0.1%
Oxygen Meter, Saturation Temp. Compensation 0-50°C automatic
Oxygen Meter, Concentration Range 0~19.9ppm
Oxygen Meter, Concentration Accuracy ± 0.2ppm
Oxygen Meter, Concentration Resolution 0.1ppm
Oxygen Meter, Concentration Temp. Compensation 0-50°C automatic
Oxygen Meter, Temperature Range -100°C to +200°C
Oxygen Meter, Temperature Accuracy ±0.3°C
Oxygen Meter, Temperature Resolution 0.1°C

Technical Data

Wetted Wall Column

Parameter Value
Height 900mm
Internal Diameter 32mm
Material Glass

Deoxygenating Column

Parameter Value
Height 1570mm
Internal Diameter 26mm
Material Clear acrylic
Range 600~5,000 ml/min

Water Flowmeter

Parameter Value
Range 1~7 l/min

Air

Parameter Value
Range 0.1~1m3/h

Deoxygenator

Parameter Value
Feed Pump 20 l/min @ 2m head

Absorption Column

Parameter Value
Feed Pump 10 l/min @ 1m head

Air Feed

Parameter Value
Feed Pump 24 l/min @ 1 kg/cm2

Sump Tank

Parameter Value
Capacity Approx 40l

Oxygen Meter, Saturation

Parameter Value
Range 0-199.9%
Accuracy ± 0.5%
Resolution 0.1%
Temperature Compensation 0-50°C automatic

Oxygen Meter, Concentration

Parameter Value
Range 0~19.9ppm
Accuracy ± 0.2ppm
Resolution 0.1ppm
Temperature Compensation 0-50°C automatic

Oxygen Meter, Temperature

Parameter Value
Range -100°C to +200°C
Accuracy ±0.3°C
Resolution 0.1°C

Key Features

  • Column Type: Wetted wall gas absorption column for liquid film mass transfer studies
  • Wetted Wall Column: Glass, 900mm height, 32mm internal diameter
  • Deoxygenating Column: Clear acrylic, 1570mm height, 26mm internal diameter
  • Deoxygenation Method: Nitrogen sparging of water
  • Water Flow Control: Flowmeter, range 1~7 l/min
  • Air Flow Control: Range 0.1~1m3/h
  • Deoxygenator Feed Pump: 20 l/min @ 2m head
  • Absorption Column Feed Pump: 10 l/min @ 1m head
  • Air Feed Pump: 24 l/min @ 1 kg/cm2
  • Sump Tank: Approx 40l capacity
  • Oxygen Saturation Measurement: Range 0-199.9%, accuracy ± 0.5%
  • Oxygen Concentration Measurement: Range 0~19.9ppm, accuracy ± 0.2ppm
  • Temperature Measurement: Range -100°C to +200°C, accuracy ±0.3°C

Experiments

  • Calculation of liquid film mass transfer coefficients
  • Variation of coefficient with mass flow rate
  • Variation of oxygen flow rate to determine power law relationship

Construction and Design

The Wetted Wall Gas Absorption Column ReaktiLabX 16 consists of a wetted wall column made of glass, 900mm in height with a 32mm internal diameter. A deoxygenating column made of clear acrylic is 1570mm in height with a 26mm internal diameter and a range of 600~5,000 ml/min. Water flow is regulated using a flowmeter with a range of 1~7 l/min. Air flow is regulated with a range of 0.1~1m3/h. The deoxygenator feed pump operates at 20 l/min at 2m head. The absorption column feed pump operates at 10 l/min at 1m head. The air feed pump operates at 24 l/min at 1 kg/cm2. The sump tank has a capacity of approximately 40l. An oxygen meter measures saturation, concentration, and temperature. Saturation is measured over a range of 0-199.9% with ± 0.5% accuracy and 0.1% resolution, with automatic temperature compensation from 0-50°C. Concentration is measured over a range of 0~19.9ppm with ± 0.2ppm accuracy and 0.1ppm resolution, with automatic temperature compensation from 0-50°C. Temperature is measured over a range of -100°C to +200°C with ±0.3°C accuracy and 0.1°C resolution. This construction allows the wetted wall gas absorption column to demonstrate controlled liquid film absorption using deoxygenated water and nitrogen sparging.

Scope of Delivery

  • 1 experimental unit
  • 1 instruction manual

Q: What is the Wetted Wall Gas Absorption Column ReaktiLabX 16 used for?
A: It is used to find gas/liquid mass transfer coefficients, which are crucial for estimating the design of absorption towers, by studying the uptake of oxygen into deoxygenated water.

Q: How is the water deoxygenated?
A: Water is deoxygenated by nitrogen sparging in a clear acrylic deoxygenating column, 1570mm in height with a 26mm internal diameter.

Q: What experiments can be performed on this unit?
A: Calculation of liquid film mass transfer coefficients, variation of coefficient with mass flow rate, and variation of oxygen flow rate to determine power law relationship.

Q: What is the material and size of the wetted wall column?
A: The wetted wall column is made of glass, 900mm in height with a 32mm internal diameter.

Q: What does the scope of delivery include?
A: 1 experimental unit and 1 instruction manual.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Wetted Wall Gas Absorption Column | ReaktiLabX 16 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send model, quantity, destination port and Incoterm. Proforma back with the full export documentation set listed.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender? A missing manufacturer authorisation form (MAF) gets a bid rejected before price is opened. Send the tender reference and closing date.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Tubular Reactor | ReaktiLabX – 11Batch Stirred Tank Reactor (Stand Alone) | ReaktiLabX – 18Tubular Flow Reactor | ReaktiLabX – 06Continuous Stirred Tank Reactor (Stand Alone) | ReaktiLabX – 13Trickle Bed Reactor | ReaktiLabX 15Continuous Stirred Tank Reactor | ReaktiLabX – 08Stirred Tanks in Series | ReaktiLabX – 09Continuous Stirred Tank Reactor in Series (Stand Alone) | ReaktiLabX – 14
📄 Download Datasheet