🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
✓ Established 1993 ✓ Model-Specific Specifications ✓ Manufacturer-Direct Enquiries ✓ International Quotations ✓ Destination-Based Delivery Terms

Fluidization and Fluid Bed Heat Exchanger

Model OperatiX - 03

The Fluidization and Fluid Bed Heat Exchanger OperatiX – 03 gives students visual insight into air flow through packed and fluidized beds. This Fluidization and Fluid Bed Heat Exchanger features a glass reactor chamber with an electrical heater, air distributor, and dual rotameters for flow measurement. It includes four grades of Fused Alumina bed material for fluidization and heat transfer studies. Optional DAQ software enables measurement and calculation of results.

The Fluidization and Fluid Bed Heat Exchanger OperatiX – 03 gives students a visual understanding of air flow through both packed and fluidized beds of granular material. This Fluidization and Fluid Bed Heat Exchanger contains bed material in a glass container fitted with an electrical heater. It uses air as the fluidizing medium, supported by an air distributor-equipped distribution chamber.

Product Overview

The process of crystallization is typically used to clean up substances so that the components of a solution may be separated. To crystallize a solute, a solution must achieve a supersaturated state. A substance, referred to as a solute, must be dissolved in a solution to the point where the solution is unable to dissolve any more solute. To create a supersaturated solution, one of several techniques can be employed.

For students to have a visual knowledge of the flow of air through both a packed and a fluidized bed of granular material, the Fluidization and Fluid Bed Heat Transfer Unit has been created. The bed material is primarily contained in a glass container inside of which is an electrical heater. The chamber has an air distributor-equipped distribution chamber. For the measurements of temperature, pressure, and flow rate, instruments are available. The fluidizing medium in the device is air.

A glass cylinder with a bed of a selected granular substance makes up the Fluidization and Fluid Bed Heat Exchanger. A distributor chamber with an air distributor supports the bed material at the bottom end of the glass chamber. The air distributor minimizes pressure loss while maintaining a consistent airflow into the bed. For student projects and other research, a self-designed distributor can take the place of the distributor. Air exits the bed through an air filter, travels through the chamber, and then leaves the bed. The brackets attached on the panel are used to suspend the chamber, filter, and distributor assembly.

Before entering the distribution chamber, air from the nearby compressed air supply is routed through a filter/pressure regulator, airflow rotameters, and air flow control valves. The heater input power is shown on the control panel, and a variable transformer is supplied for controlling the heating power. A thermocouple is installed on the heating element to measure the surface temperature of the heater. Digital readouts of each relevant temperature are shown on the control panel. A manometer with liquid inside of it measures the pressure decrease at any point along the bed. Additionally, the chamber is equipped with a pressure relief device that releases air into the atmosphere whenever the chamber’s pressure rises above the permitted level. The bed material can be simply changed according to the unit’s architecture. The unit comes with four grades of Fused Alumina (Aluminum Oxide) loose grains that can be utilized for a variety of fluidization and heat transfer investigations.

Fluidization and Fluid Bed Heat Exchanger OperatiX – 03, Technical Specifications

Specification Detail
Chamber Glass chamber containing the bed material and an electrical heater for heat transfer studies
Reactor Chamber Glass, fitted with distribution chamber, air distributor, air filter, electrical heater, temperature sensors, and pressure drop measuring probe
Air Flow Adjustment Manual, using a valve and flow meter
Measurement Tools Steel rulers for determining fluidized bed height and heating element immersion depth
Study Focus Investigation of fluidized bed formation and fluidized bed heat transfer
Fluidizing Medium Fluidized bed of aluminum oxide and compressed air
Sensors Digital indicators for heater temperature, air inlet in fluidized bed, pressure gauge upstream of reactor and in fluidized bed, rotameter for air flow rate and heater power
Safety Safety valve, temperature cutoff at the heater, air filter at the outlet

Technical Data

Reactor Chamber

Parameter Value
Material Glass
Capacity 3L

Electrical Heater

Parameter Value
Power 250 W
Surface Area 22.8 cm²
Safety High temp cut-off by means of a temperature controller

Flow Meters

Parameter Value
Configuration Two rotameters installed for high and low air flow measurement
Low Flow 0.25~2.5 m³/h @ 1 atm
High Flow 0.8~8 m³/h @ 1 atm

Manometers

Parameter Value
Purpose To measure the pressure drop through bed
Range 400 mm H2O
Quantity 2

Digital Displays

Parameter Value
Function To indicate temperature and heater power measurement

Safety Features

Parameter Value
Electrical Protection Electrical components are properly fused and earthed

General Requirements

Parameter Value
Compressed Air 200 LPM
Pressure 0 to 10 bar

Key Features

  • Reactor Chamber: glass, 3L capacity
  • Electrical Heater: 250W, 22.8 cm² surface area, high temp cut-off at 150°C
  • Flow Measurement: two rotameters, low flow 0.25~2.5 m³/h and high flow 0.8~8 m³/h
  • Pressure Measurement: 2 manometers, range 400 mm H2O
  • Bed Material: four grades of Fused Alumina (Aluminum Oxide) loose grains included
  • Air Distribution: air distributor minimizes pressure loss for consistent airflow into the bed
  • Safety: safety valve, temperature cutoff at heater, air filter at outlet
  • Digital Readouts: temperature and heater power displayed on control panel
  • Fluidization Study: demonstrates packed and fluidized bed behavior on this Fluidization and Fluid Bed Heat Exchanger
  • Software: optional DAQ software for measurement and calculation

Experiments

  • The unit is suitable for students’ experiments on the characteristic of air flow through a fixed bed and fluidized bed
  • To study the behavior of a fluidized bed for various types of granular materials
  • To study the changes of pressure drop as a function of air flow for a variety of granular materials, both as packed and fluidized beds
  • To study the effect of superficial velocity, immersion depth, and particle size on the surface heat transfer coefficient for a hot surface in a fluidized bed
  • To study the effect of distributor design on the bed behavior

Construction and Design

The Fluidization and Fluid Bed Heat Exchanger OperatiX – 03 incorporates a glass chamber containing the bed material and an electrical heater for heat transfer studies. The reactor chamber, made of glass with a 3L capacity, is fitted with a distribution chamber, air distributor, air filter, electrical heater, temperature sensors, and a pressure drop measuring probe. A distributor chamber with an air distributor supports the bed material at the bottom end of the glass chamber, minimizing pressure loss while maintaining consistent airflow. Air exits the bed through an air filter before leaving the chamber. The electrical heater is rated at 250W with a 22.8 cm² surface area and a high temperature cut-off set to 150°C. Two rotameters measure low flow (0.25 to 2.5 m³/h) and high flow (0.8 to 8 m³/h) air rates. Two manometers, ranged to 400 mm H2O, measure pressure drop through the bed. Steel rulers determine the fluidized bed’s height and the heating element’s immersion depth. A pressure relief device releases air into the atmosphere if chamber pressure rises above the permitted level. The unit comes with four grades of Fused Alumina (Aluminum Oxide) loose grains for fluidization and heat transfer investigations.

Software

Software OperatiX – 03 (optional). DAQ software specially designed in National Instrument™, LABVIEW™ environment to measure and calculate the results of the apparatus. The software is optional; a set of electronic sensors is included when the software is used. The software can be run in any Windows™ environment.

Scope of Delivery

  • 1 Experimental unit
  • 1 Instruction manual

Q: What is the Fluidization and Fluid Bed Heat Exchanger OperatiX – 03 used for?
A: It is used for student experiments on air flow characteristics through fixed and fluidized beds, and for studying fluidized bed heat transfer.

Q: What bed material is included with the unit?
A: The unit comes with four grades of Fused Alumina (Aluminum Oxide) loose grains for fluidization and heat transfer investigations.

Q: What is the power rating of the electrical heater?
A: The electrical heater is rated at 250W, with a surface area of 22.8 cm² and a high temperature cut-off set to 150°C.

Q: How is pressure drop measured in the bed?
A: Pressure drop is measured using 2 manometers with a range of 400 mm H2O.

Q: Is data acquisition software available with this system?
A: Yes, Software OperatiX – 03 is available as an optional add-on, designed in National Instrument™ LABVIEW™ environment, and can run in any Windows™ environment.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Fluidization and Fluid Bed Heat Exchanger | OperatiX – 03 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send the model, quantity, destination and required Incoterm. We will confirm the supplied scope and available export documents.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender that requests a manufacturer authorisation form (MAF)? Send the tender reference, deadline and listed equipment so we can confirm what can be issued.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Unit OperationsModel OperatiX - 03
🏭
Manufacturer DirectProduct-specific enquiry, not a generic catalogue
🌍
Destination MatchedConfiguration and delivery scope reviewed together
📄
Decision-Ready ReplyApplicable documentation confirmed before ordering
Product-specific enquiry

Get a quotation your team can evaluate

A bare price can hide configuration, accessories, voltage, documentation and delivery assumptions. Send the product and destination now so the quoted scope can be reviewed before a purchase decision.

Avoid the mismatchDo not approve a generic price that leaves supplied scope unclear.
Your product is attachedNo need to retype the model or copy the page URL.
Move toward an approvable quoteAdd the destination; quantity and tender details can follow.

No account is required. Organisation, quantity and tender details are optional. Include the country code so the team can reach you internationally.

1993
Manufacturing Since
Direct
Manufacturer Supply
Quote-based
International Orders
Model
OperatiX - 03

Overview

The Fluidization and Fluid Bed Heat Exchanger OperatiX - 03 gives students a visual understanding of air flow through both packed and fluidized beds of granular material. This Fluidization and Fluid Bed Heat Exchanger contains bed material in a glass container fitted with an electrical heater. It uses air as the fluidizing medium, supported by an air distributor-equipped distribution chamber.

Product Overview

The process of crystallization is typically used to clean up substances so that the components of a solution may be separated. To crystallize a solute, a solution must achieve a supersaturated state. A substance, referred to as a solute, must be dissolved in a solution to the point where the solution is unable to dissolve any more solute. To create a supersaturated solution, one of several techniques can be employed.

For students to have a visual knowledge of the flow of air through both a packed and a fluidized bed of granular material, the Fluidization and Fluid Bed Heat Transfer Unit has been created. The bed material is primarily contained in a glass container inside of which is an electrical heater. The chamber has an air distributor-equipped distribution chamber. For the measurements of temperature, pressure, and flow rate, instruments are available. The fluidizing medium in the device is air.

A glass cylinder with a bed of a selected granular substance makes up the Fluidization and Fluid Bed Heat Exchanger. A distributor chamber with an air distributor supports the bed material at the bottom end of the glass chamber. The air distributor minimizes pressure loss while maintaining a consistent airflow into the bed. For student projects and other research, a self-designed distributor can take the place of the distributor. Air exits the bed through an air filter, travels through the chamber, and then leaves the bed. The brackets attached on the panel are used to suspend the chamber, filter, and distributor assembly.

Before entering the distribution chamber, air from the nearby compressed air supply is routed through a filter/pressure regulator, airflow rotameters, and air flow control valves. The heater input power is shown on the control panel, and a variable transformer is supplied for controlling the heating power. A thermocouple is installed on the heating element to measure the surface temperature of the heater. Digital readouts of each relevant temperature are shown on the control panel. A manometer with liquid inside of it measures the pressure decrease at any point along the bed. Additionally, the chamber is equipped with a pressure relief device that releases air into the atmosphere whenever the chamber's pressure rises above the permitted level. The bed material can be simply changed according to the unit's architecture. The unit comes with four grades of Fused Alumina (Aluminum Oxide) loose grains that can be utilized for a variety of fluidization and heat transfer investigations.

Key Features

Key Features

  • Reactor Chamber: glass, 3L capacity
  • Electrical Heater: 250W, 22.8 cm² surface area, high temp cut-off at 150°C
  • Flow Measurement: two rotameters, low flow 0.25~2.5 m³/h and high flow 0.8~8 m³/h
  • Pressure Measurement: 2 manometers, range 400 mm H2O
  • Bed Material: four grades of Fused Alumina (Aluminum Oxide) loose grains included
  • Air Distribution: air distributor minimizes pressure loss for consistent airflow into the bed
  • Safety: safety valve, temperature cutoff at heater, air filter at outlet
  • Digital Readouts: temperature and heater power displayed on control panel
  • Fluidization Study: demonstrates packed and fluidized bed behavior on this Fluidization and Fluid Bed Heat Exchanger
  • Software: optional DAQ software for measurement and calculation

Experiments

  • The unit is suitable for students' experiments on the characteristic of air flow through a fixed bed and fluidized bed
  • To study the behavior of a fluidized bed for various types of granular materials
  • To study the changes of pressure drop as a function of air flow for a variety of granular materials, both as packed and fluidized beds
  • To study the effect of superficial velocity, immersion depth, and particle size on the surface heat transfer coefficient for a hot surface in a fluidized bed
  • To study the effect of distributor design on the bed behavior

Construction and Design

The Fluidization and Fluid Bed Heat Exchanger OperatiX - 03 incorporates a glass chamber containing the bed material and an electrical heater for heat transfer studies. The reactor chamber, made of glass with a 3L capacity, is fitted with a distribution chamber, air distributor, air filter, electrical heater, temperature sensors, and a pressure drop measuring probe. A distributor chamber with an air distributor supports the bed material at the bottom end of the glass chamber, minimizing pressure loss while maintaining consistent airflow. Air exits the bed through an air filter before leaving the chamber. The electrical heater is rated at 250W with a 22.8 cm² surface area and a high temperature cut-off set to 150°C. Two rotameters measure low flow (0.25 to 2.5 m³/h) and high flow (0.8 to 8 m³/h) air rates. Two manometers, ranged to 400 mm H2O, measure pressure drop through the bed. Steel rulers determine the fluidized bed's height and the heating element's immersion depth. A pressure relief device releases air into the atmosphere if chamber pressure rises above the permitted level. The unit comes with four grades of Fused Alumina (Aluminum Oxide) loose grains for fluidization and heat transfer investigations.

Software

Software OperatiX - 03 (optional). DAQ software specially designed in National Instrument™, LABVIEW™ environment to measure and calculate the results of the apparatus. The software is optional; a set of electronic sensors is included when the software is used. The software can be run in any Windows™ environment.

Scope of Delivery

  • 1 Experimental unit
  • 1 Instruction manual

Specifications

Fluidization and Fluid Bed Heat Exchanger OperatiX - 03, Technical Specifications

Specification Detail
Chamber Glass chamber containing the bed material and an electrical heater for heat transfer studies
Reactor Chamber Glass, fitted with distribution chamber, air distributor, air filter, electrical heater, temperature sensors, and pressure drop measuring probe
Air Flow Adjustment Manual, using a valve and flow meter
Measurement Tools Steel rulers for determining fluidized bed height and heating element immersion depth
Study Focus Investigation of fluidized bed formation and fluidized bed heat transfer
Fluidizing Medium Fluidized bed of aluminum oxide and compressed air
Sensors Digital indicators for heater temperature, air inlet in fluidized bed, pressure gauge upstream of reactor and in fluidized bed, rotameter for air flow rate and heater power
Safety Safety valve, temperature cutoff at the heater, air filter at the outlet

Technical Data

Reactor Chamber

Parameter Value
Material Glass
Capacity 3L

Electrical Heater

Parameter Value
Power 250 W
Surface Area 22.8 cm²
Safety High temp cut-off by means of a temperature controller

Flow Meters

Parameter Value
Configuration Two rotameters installed for high and low air flow measurement
Low Flow 0.25~2.5 m³/h @ 1 atm
High Flow 0.8~8 m³/h @ 1 atm

Manometers

Parameter Value
Purpose To measure the pressure drop through bed
Range 400 mm H2O
Quantity 2

Digital Displays

Parameter Value
Function To indicate temperature and heater power measurement

Safety Features

Parameter Value
Electrical Protection Electrical components are properly fused and earthed

General Requirements

Parameter Value
Compressed Air 200 LPM
Pressure 0 to 10 bar

Buying Fluidization and Fluid Bed Heat Exchanger: Distributor & Tender Guidance

Fluidization and Fluid Bed Heat Exchanger is the product name procurement teams should use when searching, preparing a BOQ or comparing suppliers. A model reference identifies the proposed configuration; it should not replace the product name or the buyer’s required experiment. This equipment is considered for chemical and process-engineering teaching on separation, mixing, drying, filtration, mass transfer or other unit operations.

What to include in the RFQ

State the product name, quantity, destination, curriculum or tender reference, and process capacity, contact or separation section, feed and collection arrangement, instrumentation, materials of construction, utilities and experiments. This lets the technical team respond against the intended use rather than guess from a model code.

How distributors should quote it

Keep Fluidization and Fluid Bed Heat Exchanger as the BOQ line item. Add the proposed model, included accessories, documentation, packing and delivery basis as separate fields so the end buyer can verify the offer.

How to compare suppliers

Confirm the process flow, measurement points and supplied consumables or accessories for the exact operation required. Record exclusions and alternatives in writing before commercial comparison.

Why Buy From Scientico

🏭

In-House Manufacturer

Designed & built in our Ambala facility since 1993 — not a reseller. Full control over quality & customisation.

✅

Configuration Review

Specifications, documentation and options are confirmed against the selected model.

🌏

International Enquiries

Share your destination and procurement requirements for an export quotation.

📦

Quote-Based Supply

Send the model, quantity and delivery location for a tailored proposal.

🛠

Support Scope

Support and warranty terms are documented in the applicable quotation.

🎓

Built for Teaching

Designed around curriculum experiments with clear, repeatable, hands-on results.

Frequently Asked Questions

Q: What is the Fluidization and Fluid Bed Heat Exchanger OperatiX - 03 used for? A: It is used for student experiments on air flow characteristics through fixed and fluidized beds, and for studying fluidized bed heat transfer.

Q: What bed material is included with the unit? A: The unit comes with four grades of Fused Alumina (Aluminum Oxide) loose grains for fluidization and heat transfer investigations.

Q: What is the power rating of the electrical heater? A: The electrical heater is rated at 250W, with a surface area of 22.8 cm² and a high temperature cut-off set to 150°C.

Q: How is pressure drop measured in the bed? A: Pressure drop is measured using 2 manometers with a range of 400 mm H2O.

Q: Is data acquisition software available with this system? A: Yes, Software OperatiX - 03 is available as an optional add-on, designed in National Instrument™ LABVIEW™ environment, and can run in any Windows™ environment.

Related Guides & Resources

In-depth guides from Scientico on Unit Operations lab setup, experiments and procurement.

Fluidization and Fluid Bed Heat Exchanger | OperatiX - 03

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Continuous Distillation Column Apparatus by Scientico IndiaContinuous Distillation Column Apparatus | OperatiX – 06Gas Absorption/Desorption Column Apparatus by Scientico IndiaGas Absorption/Desorption Column Apparatus | OperatiX – 12Continuous Cooling Crystallization Apparatus by Scientico IndiaContinuous Cooling Crystallization Apparatus | OperatiX – 01Liquid/Liquid Extraction Apparatus by Scientico IndiaLiquid/Liquid Extraction Apparatus | OperatiX – 11Bubble Cap Tray Column by Scientico IndiaBubble Cap Tray Column | OperatiX – 08Multifunction Distillation Column by Scientico IndiaMultifunction Distillation Column | OperatiX – 05Batch Distillation Column Apparatus by Scientico IndiaBatch Distillation Column Apparatus | OperatiX – 04Packed Column by Scientico IndiaPacked Column | OperatiX – 15
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.

Fluidization and Fluid Bed Heat Exchanger | OperatiX - 03