Flash and Fire Point Tester of Bitumen
Model STL 205
Flash and Fire Point Tester of Bitumen is a Cleveland open-cup tester for bitumen.
It uses an electric heater rated at least 450°C with stepless variable control.
The test cup is brass with a 62.5 to 64 mm inside diameter and a 32.5 to 34 mm inside depth.
The test flame is adjusted with a built-in needle valve and includes a complete gas supply.
It operates on 220 V, 50 Hz and includes a digital thermometer rated to at least 400°C.
The Flash and Fire Point Tester of Bitumen determines flash and fire points of bitumen by the Cleveland open-cup method. It uses an electrically operated heater with a variable voltage transformer for controlled heating.
Product Overview
The Flash and Fire Point Tester of Bitumen is an open-cup type tester built to the Cleveland open-cup method. The body is made of brass or a non-rusting metal of equivalent heat conductivity. It has an electric heater with a rheostat type heater switch and a nickel-chromium heater element. The heater uses stepless variable control. The unit includes a thermometer holder with a flash point platform. The thermometer position is adjustable and can be raised out of the way to place and remove the test cup. The test flame is adjusted through a built-in needle valve.
Flash and Fire Point Tester of Bitumen STL 205: Technical Specifications
| Parameter | Value |
|---|---|
| Test Method | Cleveland open-cup method |
| Heater Power Supply | 220 V AC |
| Heater Temperature | At least 450°C |
| Heater Temperature Control | Variable voltage transformer |
| Heater Material | Nickel-chromium |
| Heater Control Type | Stepless variable |
| Heater Power Rating | 1250 W (220 V) |
| Test Cup Material | Brass |
| Test Cup Inside Diameter | 62.5 to 64 mm |
| Test Cup Outside Diameter | 67.5 to 69 mm |
| Test Cup Inside Depth | 32.5 to 34 mm |
| Test Cup Bottom Thickness | 2.8 to 3.6 mm |
| Filling Mark Position | 9 to 10 mm from top edge |
| Test Flame Nozzle Tip Diameter | 1.6 to 5 mm |
| Test Flame Orifice Diameter | Approximately 0.8 mm |
| Test Flame Swing Radius | Minimum 150 mm |
| Orifice Center Height | Not more than 2.5 mm above cup edge |
| Thermometer Range | At least 400°C |
| Power Supply | 220 V, 50 Hz |
Technical Data
- Heating Arrangement
- Electrically operated heater: 220 V AC
- Heater temperature: at least 450°C
- Temperature control: variable voltage transformer
- Heating plate and frame/support stand included
- Thermometer fixed at center, depth adjustable
- Test Cup
- Material: brass
- Inside diameter: 62.5 to 64 mm
- Outside diameter: 67.5 to 69 mm
- Inside depth: 32.5 to 34 mm
- Bottom thickness: 2.8 to 3.6 mm
- Filling mark: 9 to 10 mm from top edge
- Flat shelf on outside included
- Test Flame Applicator and Gas Supply
- Nozzle tip diameter: 1.6 to 5 mm
- Orifice diameter: approximately 0.8 mm
- Swing radius: minimum 150 mm
- Orifice center: not more than 2.5 mm above cup edge
- Complete gas supply mechanism with controlling valve and pipe
- Thermometer
- Range: at least 400°C
- Type: mercury, digital thermometer complying with ASTM 11C and IP 28C
- Unit: Celsius
- Power Supply
- 220 V, 50 Hz
Key Features
- Flash Point Testing: Cleveland open-cup method for bitumen
- Heater Temperature: at least 450°C with stepless variable control
- Heater Element: nickel-chromium
- Heater Power: 1250 W (220 V)
- Test Flame: adjusted through built-in needle valve
- Thermometer Holder: adjustable position, raises out of the way
- Body Material: brass or non-rusting metal of equivalent heat conductivity
Experiments
Flash point and fire point determination of bitumen by the Cleveland open-cup method.
Construction and Design
The Flash and Fire Point Tester of Bitumen has a brass or non-rusting metal body. It uses a nickel-chromium heater with stepless variable control. The thermometer holder includes a flash point platform. The test flame is adjusted with a built-in needle valve.
Software
No software is included.
Scope of Delivery
- Clamps
- Shell
- Heater 1250 W (220 V)
- Wattstat
- Receptacle (110 V)
- Switch
- Flash cup
- Test flame burner
- Thermometer support
- Heating plate support
- Digital thermometer complying with ASTM 11C and IP 28C, mercury type, in Celsius
- Gas cylinder (common type available in the market), connection, controlling valve, and pipe
What test method does the tester use?
It uses the Cleveland open-cup method.
What is the maximum heater temperature?
The heater reaches at least 450°C.
How is the test flame adjusted?
The test flame is adjusted through a built-in needle valve.
Can the thermometer be moved out of the way?
Yes. The thermometer can be raised out of the way to place and remove the test cup.
What is the power supply?
It runs on 220 V, 50 Hz.
Need Assistance? We're Here to Help!
Connect with our team for product specifications, pricing, and customized solutions for your institution or project.