Starters for AC and DC Motors Training Panel
Model SC-STR 2068
The Starters for AC and DC Motors Training Panel – SC-STR 2068 supplies two starters on separate insulated training panels. The AC starter includes a 3-pole contactor (20 A AC-3), phase-loss sensitive overload relay (1.6–7 A adjustable), green start and red stop pushbuttons, and indicator lamp. The DC starter provides 0–16 ohm linear adjustable resistance with start and stop controls. Both panels have 4 mm safety terminals with live parts shrouded and a PE earth socket. Printed schematics are shown on each panel. English manuals, IEC 60617 circuit diagrams, and exercise sheets are included. It complies with IEC/EN 61010-1, IEC 60947, and CE standards. It is ideal for motor starter control, protection, and overload relay operation training.
The Starters for AC and DC Motors Training Panel – SC-STR 2068 supplies two starters together: a direct-on-line starter for AC induction motors and a resistance starter for DC machines. Each is mounted on an insulated training panel with printed schematic.
Product Overview
The Starters for AC and DC Motors Training Panel – SC-STR 2068 includes an AC direct-on-line starter and a DC resistance starter, each on a separate insulated training panel with printed schematics. The AC starter has a 3-pole contactor rated 20 A AC-3 with a 220–240 V AC coil at 50–60 Hz. It includes 1 NO and 1 NC auxiliary contacts at 10 A, with ON/OFF indication. The overload relay is phase-loss sensitive and trip-free, adjustable 1.6–7 A, with 1 NC trip contact and manual/auto reset plus test button. Controls include green start and red stop pushbuttons, an indicator lamp, and motor supply at 3-phase 380–400 V. The DC starter has adjustable resistance 0–16 ohm linear, start and stop pushbuttons, and a maximum current of approximately 7 A at 250 W. Both panels are insulated with 4 mm safety terminals. All live parts are shrouded. A PE terminal on a 4 mm socket provides earth connection. The unit complies with IEC/EN 61010-1, IEC 60947, and CE standards.
Starters for AC and DC Motors Training Panel – SC-STR 2068: Technical Specifications
| Category | Specification |
|---|---|
| AC Starter Contactor | 3-pole, 20 A AC-3; coil 220–240 V AC, 50–60 Hz |
| AC Starter Auxiliaries | 1 NO and 1 NC auxiliary contacts, 10 A; ON/OFF indication |
| AC Starter Overload Relay | Phase-loss sensitive, trip-free; 1.6–7 A adjustable; 1 NC trip contact |
| AC Starter Reset | Manual and auto reset options; test button included |
| AC Starter Controls | Green start pushbutton; red stop pushbutton; indicator lamp |
| AC Starter Supply | 3-phase 380–400 V motor supply |
| DC Starter Resistance | 0–16 ohm, linear adjustable |
| DC Starter Controls | Start and stop pushbuttons |
| DC Starter Rating | Maximum approximately 7 A; 250 W |
| Panel Construction | Insulated board; 4 mm safety terminals; all live parts shrouded |
| Earthing | PE terminal on 4 mm safety socket |
| Compliance | IEC/EN 61010-1; IEC 60947; documentation reviewed per model |
Key Features
- Dual Starters: AC direct-on-line and DC resistance starters supplied together
- AC Contactor: 3-pole, 20 A AC-3, 220–240 V coil, 50–60 Hz
- Overload Protection: phase-loss sensitive, trip-free, 1.6–7 A adjustable
- Auxiliary Contacts: 1 NO and 1 NC at 10 A for signalling and interlocking
- Manual Reset: manual and auto reset options with test button
- DC Starter: 0–16 ohm linear adjustable resistance for smooth starting
- Start/Stop Controls: separate pushbuttons for AC and DC control
- Indicator Lamp: ON/OFF status indication on AC starter
- Safety Terminals: 4 mm sockets with all live parts shrouded
- Compliance: IEC/EN 61010-1, IEC 60947, CE standards
Experiments
- AC direct-on-line motor starting and stopping using contactor
- Overload relay setting and trip operation
- Phase-loss detection and protection action
- Manual and automatic reset operation
- Auxiliary contact operation and use in interlocking circuits
- DC motor starting with adjustable resistance control
- Smooth acceleration effect of resistance starter on DC motor
- Current measurement during AC motor starting transient
- Comparison of AC contactor and DC starter characteristics
- Protection device operation under fault conditions
Construction and Design
The Starters for AC and DC Motors Training Panel – SC-STR 2068 comprises two separate insulated training panels. The AC starter panel contains a 3-pole contactor, phase-loss sensitive overload relay, green start and red stop pushbuttons, and an indicator lamp. The DC starter panel contains an adjustable 0–16 ohm linear resistance with start and stop pushbuttons. Both panels have 4 mm safety terminals with all live parts shrouded. A PE terminal on a 4 mm socket provides earth connection. Printed schematics are displayed on each panel for reference during training.
Scope of Delivery
- AC DOL starter panel
- DC starter panel
- English manual, IEC 60617 circuit diagrams and exercise sheets
Q: What type of AC starter is included?
A: A direct-on-line (DOL) starter with a 3-pole contactor rated 20 A AC-3, 220–240 V coil, 50–60 Hz, phase-loss sensitive overload relay, and manual/auto reset options.
Q: How does the overload relay protect the motor?
A: The phase-loss sensitive overload relay detects overcurrent conditions. It is adjustable 1.6–7 A and can be set to trip when current exceeds the motor’s safe operating range. It has both manual and automatic reset options.
Q: What does the DC starter do?
A: The DC starter provides adjustable resistance 0–16 ohm in linear steps to control current during motor starting. It allows smooth acceleration instead of sudden high inrush current.
Q: Are the terminals safe to use?
A: Yes. All terminals are 4 mm safety sockets. All live parts are shrouded to prevent accidental contact. A PE terminal provides earth connection.
Q: What standards does this training panel comply with?
A: The Starters for AC and DC Motors Training Panel – SC-STR 2068 complies with IEC/EN 61010-1, IEC 60947, and CE standards.
Need Assistance? We're Here to Help!
Connect with our team for product specifications, pricing, and customized solutions for your institution or project.