🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
Established 1993 Model-Specific Specifications Manufacturer-Direct Enquiries International Quotations Destination-Based Delivery Terms

Batch Stirred Tank Reactor (Stand Alone) | ReaktiLabX – 18

The Batch Stirred Tank Reactor (Stand Alone) ReaktiLabX – 18 operates as a self-contained unit for studying batch reactor behavior. This Batch Stirred Tank Reactor (Stand Alone) features a glass reactor with adjustable volume from 1500 to 1950mL, three stirrers, and a stainless steel chambered bottom for isothermal heat exchange. It preheats reactants before delivery and tracks conversion using a combined conductivity and temperature sensor. Optional DAQ software enables measurement and calculation of results.

The Batch Stirred Tank Reactor (Stand Alone) ReaktiLabX – 18 is typically employed when reaction rates are extremely slow or product amounts to be produced are minimal. This Batch Stirred Tank Reactor (Stand Alone) is a complete self-contained batch type unit, operating standalone with its own heating water circuit, pumps, and reactant and product tanks. It preheats reactants at the beginning of the unit before delivery into the reactor.

Product Overview

Discontinuously operated stirred tank reactors are typically employed when the reaction rates are extremely slow or the product amounts to be produced are minimal.

This equipment series that enables research with several reactor types includes this small batch reactor. A discontinuous stirred tank reactor’s behavior and operation can be studied. The apparatus includes a heating water circuit in addition to all required connections, pumps, reactant and product tanks, and tanks for reactants. The reactor is attached to the device and secured in place by two pins. The reactor and the unit can be connected via quick-release connections.

In the beginning of the unit, the reactants are preheated. Deliveries of the reactants into the stirred tank reactor follow. By ensuring a homogenous mixture, a stirrer extends the amount of time that the reactants are in direct contact. In an isothermal operation, this Batch Stirred Tank Reactor (Stand Alone)’s chambered bottom acts as a heat exchanger to study how temperature affects the reaction. By measuring the conductivity, the conversion in the stirred tank reactor is identified. The item comes with a conductivity/temperature sensor that works together. Temperature and conductivity are digitally shown on the unit’s control cabinet.

Batch Stirred Tank Reactor (Stand Alone) ReaktiLabX – 18 — Technical Specifications

Specification Detail
Operation Mode Complete self-contained batch type stirred tank reactor to operate standalone
Reactor With stirrer
Chambered Bottom Made of stainless steel as heat exchanger
Sensor For measuring the conductivity and temperature
Temperature Control In the reactor

Technical Data

Reactor

Parameter Value
Outer diameter 110mm
Inside diameter 100mm
Height 250mm
Adjustable volume 1500~1950mL
Material Boro 3.3 glass

Stirrer

Parameter Value
Speed approx. 300min⁻¹
Quantity 3

Peristaltic Pump for Reactants

Parameter Value
Quantity 2
Max. flow rate approx. 500mL/min

Peristaltic Pump for Products

Parameter Value
Max. flow rate approx. 500mL/min

Water Pump

Parameter Value
Max. flow rate 10L/min
Max. head 10m
Power consumption 120W

Heater

Parameter Value
Power consumption 3000W

Tanks

Parameter Value
Reactants 2x 3L
Product 5L
Heating water 8L

Measuring Ranges

Parameter Value
Conductivity 0~200mS/cm
Temperature 0~60°C

Key Features

  • Reactor Dimensions: 110mm outer diameter, 100mm inside diameter, 250mm height, boro 3.3 glass
  • Adjustable Volume: 1500~1950mL
  • Stirrers: 3, approx. 300min⁻¹ speed
  • Reactant Pumps: 2 peristaltic pumps, approx. 500mL/min max. flow rate each
  • Product Pump: peristaltic, approx. 500mL/min max. flow rate
  • Water Pump: 10L/min max. flow, 10m max. head, 120W power consumption
  • Heater: 3000W power consumption
  • Tanks: 2x 3L reactant tanks, 5L product tank, 8L heating water tank
  • Chambered Bottom: stainless steel, functions as heat exchanger for isothermal operation
  • Self-Contained Design: built-in pumps, tanks, and heating circuit make this Batch Stirred Tank Reactor (Stand Alone) fully independent

Experiments

  • Fundamentals of a saponification reaction
  • Determination of reaction rate constant
  • Determination of temperature dependence of reaction rate constant
  • Conversion depending on: reaction time, temperature, concentration

Construction and Design

The Batch Stirred Tank Reactor (Stand Alone) ReaktiLabX – 18 uses a reactor 110mm in outer diameter, 100mm in inside diameter, 250mm in height, made of boro 3.3 glass, with an adjustable volume of 1500 to 1950mL. Three stirrers, operating at approximately 300min⁻¹, ensure a homogenous mixture and extend reactant contact time. The reactor’s chambered bottom, made of stainless steel, acts as a heat exchanger for isothermal operation, studying temperature effects on the reaction. The reactor is secured to the unit using two pins and connects via quick-release connections. Two peristaltic pumps, each with a maximum flow rate of approximately 500mL/min, deliver reactants, while a separate peristaltic pump handles product delivery at the same flow rate. A water pump, rated 10L/min max. flow, 10m max. head, and 120W power consumption, works with a 3000W heater for temperature regulation. Tanks include two 3L reactant tanks, a 5L product tank, and an 8L heating water tank. Reactants are preheated at the beginning of the unit before delivery into the reactor. A combined conductivity and temperature sensor identifies conversion, with values digitally shown on the unit’s control cabinet.

Software

Software ReaktiLabX – 18 (optional). DAQ software specially designed in National Instrument™, LABVIEW™ environment to measure and calculate the results of the apparatus. The software is optional; a set of electronic sensors is included when the software is used. The software can be run with any Windows™ environment.

Q: What is the Batch Stirred Tank Reactor (Stand Alone) ReaktiLabX – 18 used for?
A: It is used to study discontinuous stirred tank reactor behavior, including saponification reaction fundamentals, reaction rate constant determination, and conversion analysis.

Q: What makes this reactor a “standalone” unit?
A: The apparatus includes its own heating water circuit, connections, pumps, and reactant and product tanks, allowing it to operate as a complete, self-contained batch type unit.

Q: What is the adjustable volume range of the reactor?
A: The reactor volume is adjustable between 1500 and 1950mL.

Q: How does the reactor’s chambered bottom function?
A: The chambered bottom, made of stainless steel, acts as a heat exchanger, supporting isothermal operation and temperature effect studies.

Q: Is data acquisition software available with this system?
A: Yes, Software ReaktiLabX – 18 is available as an optional add-on, designed in National Instrument™ LABVIEW™ environment, and can run with any Windows™ environment.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Batch Stirred Tank Reactor (Stand Alone) | ReaktiLabX – 18 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send model, quantity, destination port and Incoterm. Proforma back with the full export documentation set listed.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender? A missing manufacturer authorisation form (MAF) gets a bid rejected before price is opened. Send the tender reference and closing date.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Wetted Wall Gas Absorption Column | ReaktiLabX 16Continuous Stirred Tank Reactor (Stand Alone) | ReaktiLabX – 13Tubular Reactor | ReaktiLabX – 11Continuous Stirred Tank Reactor | ReaktiLabX – 08Tubular Flow Reactor | ReaktiLabX – 06Continuous Stirred Tank Reactor in Series (Stand Alone) | ReaktiLabX – 14Trickle Bed Reactor | ReaktiLabX 15Corrosion Study Unit | ReaktiLabX – 04
📄 Download Datasheet