🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
✓ Established 1993 ✓ Model-Specific Specifications ✓ Manufacturer-Direct Enquiries ✓ International Quotations ✓ Destination-Based Delivery Terms

Flapper Nozzle System | Prozessi PX 23

The Flapper Nozzle System Prozessi PX 23 demonstrates the conversion of mechanical motion to pneumatic pressure signals. This Flapper Nozzle System uses a precision flapper-nozzle mechanism with two pressure gauges and a 1 micron dial gauge for measuring displacement-pressure relationships. Two experiments cover flapper-nozzle system operation and gain calculation. Compact design, 300W x 150D x 250H mm, requires clean compressed air at 2 Bar, 50 LPH.

The Flapper Nozzle System Prozessi PX 23 is designed to teach the conversion of mechanical motion into a pressure signal. This Flapper Nozzle System demonstrates how a flapper-nozzle mechanism responds to displacement and generates proportional pressure output, a fundamental principle in pneumatic control devices.

Product Overview

The Flapper Nozzle System Prozessi PX 23 demonstrates the flapper-nozzle conversion mechanism commonly used in industrial process control. The system consists of a flapper-nozzle mechanism where a regulated air supply (typically over 20 psig) flows through a restriction toward an open nozzle. The gap between the nozzle and flapper determines the air escape rate and thus the pressure downstream of the restriction. As the flapper moves, it changes this gap and modulates the output pressure. A precision dial gauge with 1 micron least count measures flapper movement displacement. Two pressure gauges (0-2.5 kg/cm2 range) monitor system pressure and output pressure. An air regulator (0-2 kg/cm2 range) controls the input air supply. The Flapper Nozzle System is compact and simple to operate, measuring 300W x 150D x 250H mm. It requires clean, oil and moisture-free compressed air at 2 Bar pressure, 50 LPH consumption. An optional support table (800W x 800D x 750H mm) is available for laboratory installation.

Flapper Nozzle System Prozessi PX 23 — Technical Specifications

Specification Value
Product Code PX 23
Dial Gauge Least count 1 micron
Air Regulator Range 0-2 kg/cm2
Pressure Gauge 1 Range 0-2.5 kg/cm2
Pressure Gauge 2 Range 0-2.5 kg/cm2
Overall Dimensions W 300 x D 150 x H 250 mm
Air Supply Required Clean, oil and moisture-free air, 2 Bar pressure, 50 LPH consumption

Technical Data

Flapper-Nozzle Mechanism Components

Component Specification
Flapper Element Precision pivoted mechanism
Nozzle Fixed orifice with controlled restriction
Gap Adjustment Variable nozzle-flapper separation
Movement Measurement Micron dial gauge, 1 micron resolution

Pressure Measurement and Control

Component Specification
Air Regulator Range 0-2 kg/cm2, controls input supply pressure
Pressure Gauge 1 Range 0-2.5 kg/cm2, monitors supply pressure
Pressure Gauge 2 Range 0-2.5 kg/cm2, monitors output pressure
Pressure Measurement Principle Differential pressure across restriction varies with flapper gap

Air Supply Requirements

Requirement Specification
Air Quality Clean, oil and moisture-free
Supply Pressure 2 Bar nominal
Consumption 50 LPH
Filtration Oil removal and moisture control required

Key Features

  • Flapper Nozzle System: fundamental pneumatic control device principle demonstration
  • Micron dial gauge with 1 micron least count for precision flapper displacement measurement
  • Two pressure gauges for simultaneous monitoring of supply and output pressure
  • Air regulator for controlled input pressure adjustment
  • Compact and simple to operate design
  • Direct observation of pressure-displacement relationship
  • Industrial standard mechanism used in proportional control valves

Experiments

  • Study of Flapper-Nozzle system
  • Gain calculation of Flapper-Nozzle system

Construction and Design

The Flapper Nozzle System Prozessi PX 23 is built on a compact assembly measuring 300W x 150D x 250H mm. At the heart of the system is a precision flapper-nozzle mechanism where a pivoted flapper element is positioned above a fixed nozzle opening. Regulated air supply, typically pressurized over 20 psig, flows through a restriction toward the open nozzle. Air escapes through the variable gap between the flapper and nozzle tip, creating a back-pressure that varies inversely with the gap size. As the flapper moves mechanically, the gap changes, modulating the output pressure. A precision dial gauge with 1 micron least count measures flapper displacement directly. Two pressure gauges (0-2.5 kg/cm2 range each) display supply pressure and output pressure simultaneously, allowing students to observe the pressure-motion relationship. An air regulator (0-2 kg/cm2 range) controls input air supply, enabling gain variation studies. The system requires clean, oil and moisture-free compressed air at 2 Bar pressure, consuming 50 LPH. An optional support table (800W x 800D x 750H mm) is available for secure laboratory mounting.

Operating Principle

The Flapper Nozzle System converts mechanical flapper displacement into proportional pneumatic pressure output. As flapper-nozzle gap increases, air escapes more freely, reducing back-pressure. As the gap decreases, air escape is restricted, increasing back-pressure. This linear or near-linear relationship between displacement and pressure is the fundamental operating principle of pneumatic proportional control devices and pilot-operated regulators.

Scope of Delivery

  • Flapper Nozzle System Prozessi PX 23 complete assembly
  • Precision flapper-nozzle mechanism with adjustable gap
  • Dial gauge, least count 1 micron
  • Air regulator, range 0-2 kg/cm2
  • Pressure gauge, range 0-2.5 kg/cm2 (first unit)
  • Pressure gauge, range 0-2.5 kg/cm2 (second unit)
  • Air inlet and outlet connections
  • Base assembly, 300W x 150D x 250H mm
  • User documentation and experimental manual
  • Air supply hose connections

Optional Accessories

  • Support table, size 800W x 800D x 750H mm
  • Mini compressor for independent air supply
  • Replacement dial gauge unit

Q1: What is the purpose of the Flapper Nozzle System?
A: The Flapper Nozzle System demonstrates how mechanical motion (flapper displacement) is converted into proportional pneumatic pressure signals, a fundamental principle in industrial control devices.

Q2: How does the flapper-nozzle mechanism work?
A: As the flapper moves closer to the nozzle, the gap decreases, restricting air escape and increasing back-pressure. As the flapper moves away, air escapes more freely, decreasing pressure. This creates a proportional relationship between displacement and pressure.

Q3: What is the resolution of the dial gauge?
A: The dial gauge has a least count of 1 micron, allowing precise measurement of very small flapper displacements.

Q4: What does the Flapper Nozzle System gain calculation measure?
A: The gain calculation measures how much the output pressure changes for a given change in flapper displacement, typically expressed as pressure change per unit displacement (kg/cm2 per micron).

Q5: What air supply is required for the Flapper Nozzle System?
A: The system requires clean, oil and moisture-free compressed air at 2 Bar pressure with a consumption of 50 LPH. Air must be filtered to remove oil and moisture.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Flapper Nozzle System | Prozessi PX 23 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send model, quantity, destination port and Incoterm. Proforma back with the full export documentation set listed.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender? A missing manufacturer authorisation form (MAF) gets a bid rejected before price is opened. Send the tender reference and closing date.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

First-Order-and-Second-Order-System-TrainerFirst-Order and Second-Order System Trainer | Prozessi PX 21Flow Control Trainer | Prozessi PX 15DCS Trainer | Prozessi PX 27Flow Measurement Trainer Prozessi PX 19Flow Measurement Trainer | Prozessi PX 19Control Valve Characteristics Training Panel – ProzessiX PX-06, Scientico IndiaControl Valve Characteristics Training Panel | ProzessiX PX-06Flow Through Particle Layers Trainer | ProzessiX PX-02, Scientico IndiaFlow Through Particle Layers Trainer | ProzessiX PX-02Control Valve CharacteristicsControl Valve Characteristics Trainer | Prozessi PX 20Interacting and Non Interacting SystemInteracting and Non Interacting System Trainer | Prozessi PX 26
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.

Flapper Nozzle System | Prozessi PX 23