Inductive Load Bank
Model SC-ILB 1074
The Inductive Load Bank – SC-ILB 1074 is a set of three identical iron-core inductor banks for single- and three-phase circuits. Each bank offers four taps (0.5 H, 1 H, 2 H, and 3 H) with rated currents from 2.5 A to 5 A at 50 Hz. The banks can be connected in series, parallel, star, or delta. A rotary tap selector, isolating switch, and active-tap LED are fitted to each bank. Each bank has a thermal fuse and test points, with 4 mm safety sockets for connections. It complies with IEC/EN 61010-1 and CE standards. English manuals and a tap rating table are included. It is ideal for reactive power, power factor, and inductive load experiments.
The Inductive Load Bank – SC-ILB 1074 is a set of three iron-core inductor banks for single- and three-phase circuits. It is used for reactive power and power factor experiments, with tap selection and active-tap indication.
Product Overview
The Inductive Load Bank – SC-ILB 1074 has three identical iron-core inductor banks. Each bank can be connected in series, parallel, star, or delta. Each bank has four taps: 0.5 H at 5 A, 1 H at 3.5 A, 2 H at 3 A, and 3 H at 2.5 A, all at 50 Hz. The corresponding impedances are 157, 314, 628, and 942 ohm. Each tap is rated for 230 V AC, 50 Hz continuous operation. Across a star connection, the rating is 400 V. The core is laminated iron. A rotary tap selector and isolating switch are fitted to each bank, with an LED indicating the active tap. Each bank has a thermal fuse for protection. Connections use 4 mm safety sockets, with test points on each bank. The unit complies with IEC/EN 61010-1 and CE standards, is class F and IP20, and a rating table is supplied.
Inductive Load Bank – SC-ILB 1074: Technical Specifications
| Category | Specification |
|---|---|
| Number of Banks | 3 identical banks |
| Connection Options | Series, parallel, star, delta |
| Tap 1 | 0.5 H; 5 A; 157 ohm at 50 Hz |
| Tap 2 | 1 H; 3.5 A; 314 ohm at 50 Hz |
| Tap 3 | 2 H; 3 A; 628 ohm at 50 Hz |
| Tap 4 | 3 H; 2.5 A; 942 ohm at 50 Hz |
| Rated Voltage | 230 V AC, 50 Hz continuous per tap |
| Star Connection Voltage | 400 V |
| Core | Laminated iron |
| Switching | Rotary tap selector and isolating switch per bank |
| Tap Indication | LED for active tap |
| Protection | Thermal fuse per bank |
| Connections | 4 mm safety sockets; test points per bank |
| Compliance | IEC/EN 61010-1; documentation reviewed per model |
| Insulation Class | F |
| Enclosure | IP20 |
| Documentation | Rating table supplied |
Key Features
- Three Identical Banks: series, parallel, star, or delta configurations
- Four Tap Values: 0.5 H, 1 H, 2 H, 3 H for varied reactance
- Tap Selection: rotary selector per bank with isolating switch
- Active-Tap LED: clear indication of the selected tap
- Laminated Iron Core: stable inductive performance
- Thermal Fuse: protection on each bank
- Test Points: access on each bank for measurement
- Safety Sockets: 4 mm connections for secure wiring
- Rating Table: tap ratings supplied for reference
- Compliance: IEC/EN 61010-1, CE, class F, IP20
Experiments
- Reactive power measurement at different inductance values
- Power factor measurement and lagging power factor effects
- Series and parallel inductor combination analysis
- Star and delta connection of inductive loads
- Impedance calculation from tap values at 50 Hz
- Current and voltage phase relationship in inductive circuits
- Power factor correction using capacitive banks
- Current limiting effect of inductive loads
- Comparison of tap ratings and current capacity
- Three-phase inductive load balancing
Construction and Design
The Inductive Load Bank – SC-ILB 1074 contains three identical iron-core inductor banks. Each bank has a laminated iron core with four selectable taps. A rotary tap selector and isolating switch are fitted to each bank, with an LED showing the active tap. Test points and 4 mm safety sockets provide connection access. A thermal fuse protects each bank. The banks can be connected in series, parallel, star, or delta configurations.
Scope of Delivery
- Inductive load bank
- English manual with tap rating table
Q: What taps are available on each bank?
A: Each bank has four taps: 0.5 H at 5 A, 1 H at 3.5 A, 2 H at 3 A, and 3 H at 2.5 A, all at 50 Hz. The corresponding impedances are 157, 314, 628, and 942 ohm.
Q: What voltage rating applies?
A: Each tap is rated for 230 V AC, 50 Hz continuous operation. In a star connection, the rating across the star is 400 V.
Q: How do I know which tap is selected?
A: An LED indicates the active tap on each bank, and a rotary tap selector allows you to change it.
Q: Can the banks be combined?
A: Yes. The three identical banks can be connected in series, parallel, star, or delta configurations.
Q: Is each bank protected?
A: Yes. Each bank has a thermal fuse for protection, and a rating table is supplied with the unit.
Need Assistance? We're Here to Help!
Connect with our team for product specifications, pricing, and customized solutions for your institution or project.