🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
✓ Established 1993 ✓ Model-Specific Specifications ✓ Manufacturer-Direct Enquiries ✓ International Quotations ✓ Destination-Based Delivery Terms

Cross Flow Heat Exchanger

Model ThermoFlux - 7078

The Cross Flow Heat Exchanger ThermoFlux – 7078 is a laboratory unit for investigating heat transfer by forced and free convection using three interchangeable heating elements: a pipe, a pipe bundle, and a finned pipe bundle. Each element is rated at 500 W with adjustable heating power and variable airflow up to 13 m³/min through a 120 x 120 mm vertical duct. Electronic sensors measure temperature (2x -100 to 400°C), power (0 to 500 W), and air velocity (0 to 10 m/s), with all values displayed digitally on the front panel. This cross flow heat exchanger calculates flow rate, Reynolds number, and Nusselt number, and supports optional PC data transfer with LabVIEW-based DAQ software.

The Cross Flow Heat Exchanger ThermoFlux – 7078 is a laboratory-grade unit designed to enable students to investigate heat transfer rates by free and forced convection. This cross flow heat exchanger provides hands-on experimentation with interchangeable heating elements, adjustable airflow, and digital measurement display, making it a precise tool for thermal engineering studies.


Product Overview

The Cross Flow Heat Exchanger ThermoFlux – 7078 consists of a vertical air duct through which air is drawn by a radial fan. Three interchangeable heater elements, a pipe, a pipe bundle, and a finned pipe bundle, dissipate heat directly into the airflow. Each heater element operates at 500W. The heating power is adjustable, and the air flow rate is variable, allowing systematic investigation across different conditions.

Electronic sensors measure temperature, differential pressure, and power. All measured values are displayed digitally on the front-mounted instrumentation unit. Data can also be transferred directly to a PC. The flow rate, Reynolds number, and Nusselt number are calculated from sensor data. The temperature-time relationship and the dependence of the Nusselt number on the Reynolds number can be demonstrated graphically.

The heater insert in the pipe bundle configuration can be repositioned across different pipe rows to investigate the effect of flow arrangement on heat transfer performance.

Cross Flow Heat Exchanger ThermoFlux – 7078, Technical Specifications

Parameter Value
Flow Channel Cross-Section 120 x 120 mm
Radial Fan Max. Power Consumption 250 W
Radial Fan Max. Pressure Difference 430 Pa
Radial Fan Max. Flow Rate 13 m³/min
Temperature Measuring Range 2x -100 to 400°C
Power Measuring Range 0 to 500 W
Air Velocity Measuring Range 0 to 10 m/s

Technical Data

Flow Channel

Parameter Value
Cross-Section 120 x 120 mm

Radial Fan

Parameter Value
Max. Power Consumption 250 W
Max. Pressure Difference 430 Pa
Max. Flow Rate 13 m³/min

Heating Elements

Pipe

Parameter Value
Power 1x 500 W
Heating Surface 1x approx. 0.01 m²

Pipe Bundle

Parameter Value
Power 1x 500 W
Heating Surface 1x approx. 0.005 m²

Finned Pipe Bundle

Parameter Value
Power 1x 500 W
Heating Surface 1x approx. 0.014 m²

Measuring Ranges

Parameter Value
Temperature 2x -100 to 400°C
Power 0 to 500 W
Air Velocity 0 to 10 m/s

Key Features

  • Heat Exchanger Type: Cross flow configuration, vertical air duct
  • Cross Flow Heat Exchanger Application: Forced and free convection investigation
  • Heating Elements: Pipe, pipe bundle, finned pipe bundle (interchangeable)
  • Heating Power per Element: 1x 500 W, adjustable
  • Pipe Heating Surface: approx. 0.01 m²
  • Pipe Bundle Heating Surface: approx. 0.005 m²
  • Finned Pipe Bundle Heating Surface: approx. 0.014 m²
  • Pipe Bundle Row Positioning: Adjustable for flow effect investigation
  • Air Flow: Adjustable via radial fan, max. 13 m³/min
  • Fan Max. Pressure Difference: 430 Pa
  • Fan Max. Power Consumption: 250 W
  • Flow Channel Cross-Section: 120 x 120 mm
  • Sensors: Electronic sensors for temperature, differential pressure, power
  • Temperature Range: 2x -100 to 400°C
  • Power Range: 0 to 500 W
  • Air Velocity Range: 0 to 10 m/s
  • Data Display: Digital display on front of instrumentation unit
  • PC Connectivity: Direct data transfer to PC (optional)
  • Calculated Parameters: Flow rate, Reynolds number, Nusselt number
  • Software: Optional DAQ software, ThermoFlux – 7078, LabVIEW-based

Experiments

  • Investigation of convection processes
  • Comparison of heat transfer for different heating elements
  • Comparison between different heating elements
  • Demonstration of the relationship between heat transfer, area of heat transfer and flow velocity (Nusselt)

Construction and Design

The Cross Flow Heat Exchanger ThermoFlux – 7078 is built around a vertical air duct as its primary structural element. A radial fan draws air through the duct and delivers a maximum flow rate of 13 m³/min at up to 430 Pa pressure difference. The duct cross-section measures 120 x 120 mm. Three interchangeable heater inserts are included: a single pipe, a pipe bundle, and a finned pipe bundle. Each insert is rated at 500 W. The pipe bundle insert can be positioned in different pipe rows to vary the cross flow heat exchanger flow arrangement during experiments. Electronic sensors integrated into the system measure temperature across two channels (range: -100 to 400°C), power (0 to 500 W), and air velocity (0 to 10 m/s). All sensor readings are shown on a digital display mounted on the front panel of the instrumentation unit. The unit also supports direct PC data transfer for further analysis.


Software

ThermoFlux – 7078 Software (Optional)

  • Developed in the National Instruments LabVIEW environment
  • Designed specifically for data acquisition with this apparatus
  • Records, stores, and calculates experimental results
  • Compatible with any Windows operating system
  • Electronic sensors are included when the software option is selected

Scope of Delivery

  • 1 experimental unit
  • 1 pipe bundle
  • 1 pipe element
  • 1 finned pipe bundle
  • 1 instructional manual

 

Q1: What heating elements are included with the Cross Flow Heat Exchanger ThermoFlux – 7078?
Three interchangeable heating elements are included: a pipe, a pipe bundle, and a finned pipe bundle. Each operates at 500 W.

Q2: Can the airflow rate be adjusted during experiments?
Yes. The radial fan allows variable airflow, with a maximum flow rate of 13 m³/min and a maximum pressure difference of 430 Pa.

Q3: Is the software included as standard?
No. The ThermoFlux – 7078 DAQ software is optional. When selected, it includes the required electronic sensors and runs on any Windows operating system.

Q4: What parameters does the system calculate automatically?
The unit calculates flow rate, Reynolds number, and Nusselt number from sensor data. It can also display temperature-time relationships and the dependence of Nusselt number on Reynolds number graphically.

Q5: Can the pipe bundle be repositioned within the duct?
Yes. The heater insert for the pipe bundle can be positioned in different pipe rows within the duct to investigate the effect of flow position on heat transfer performance.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Cross Flow Heat Exchanger | ThermoFlux – 7078 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send the model, quantity, destination and required Incoterm. We will confirm the supplied scope and available export documents.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender that requests a manufacturer authorisation form (MAF)? Send the tender reference, deadline and listed equipment so we can confirm what can be issued.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Thermodynamics Lab EquipmentModel ThermoFlux - 7078
🏭
Manufacturer DirectProduct-specific enquiry, not a generic catalogue
🌍
Destination MatchedConfiguration and delivery scope reviewed together
📄
Decision-Ready ReplyApplicable documentation confirmed before ordering
Product-specific enquiry

Get a quotation your team can evaluate

A bare price can hide configuration, accessories, voltage, documentation and delivery assumptions. Send the product and destination now so the quoted scope can be reviewed before a purchase decision.

Avoid the mismatchDo not approve a generic price that leaves supplied scope unclear.
Your product is attachedNo need to retype the model or copy the page URL.
Move toward an approvable quoteAdd the destination; quantity and tender details can follow.

No account is required. Organisation, quantity and tender details are optional. Include the country code so the team can reach you internationally.

1993
Manufacturing Since
Direct
Manufacturer Supply
Quote-based
International Orders
Model
ThermoFlux - 7078

Overview

The Cross Flow Heat Exchanger ThermoFlux - 7078 is a laboratory-grade unit designed to enable students to investigate heat transfer rates by free and forced convection. This cross flow heat exchanger provides hands-on experimentation with interchangeable heating elements, adjustable airflow, and digital measurement display, making it a precise tool for thermal engineering studies.


Product Overview

The Cross Flow Heat Exchanger ThermoFlux - 7078 consists of a vertical air duct through which air is drawn by a radial fan. Three interchangeable heater elements, a pipe, a pipe bundle, and a finned pipe bundle, dissipate heat directly into the airflow. Each heater element operates at 500W. The heating power is adjustable, and the air flow rate is variable, allowing systematic investigation across different conditions.

Electronic sensors measure temperature, differential pressure, and power. All measured values are displayed digitally on the front-mounted instrumentation unit. Data can also be transferred directly to a PC. The flow rate, Reynolds number, and Nusselt number are calculated from sensor data. The temperature-time relationship and the dependence of the Nusselt number on the Reynolds number can be demonstrated graphically.

The heater insert in the pipe bundle configuration can be repositioned across different pipe rows to investigate the effect of flow arrangement on heat transfer performance.

Key Features

Key Features

  • Heat Exchanger Type: Cross flow configuration, vertical air duct
  • Cross Flow Heat Exchanger Application: Forced and free convection investigation
  • Heating Elements: Pipe, pipe bundle, finned pipe bundle (interchangeable)
  • Heating Power per Element: 1x 500 W, adjustable
  • Pipe Heating Surface: approx. 0.01 m²
  • Pipe Bundle Heating Surface: approx. 0.005 m²
  • Finned Pipe Bundle Heating Surface: approx. 0.014 m²
  • Pipe Bundle Row Positioning: Adjustable for flow effect investigation
  • Air Flow: Adjustable via radial fan, max. 13 m³/min
  • Fan Max. Pressure Difference: 430 Pa
  • Fan Max. Power Consumption: 250 W
  • Flow Channel Cross-Section: 120 x 120 mm
  • Sensors: Electronic sensors for temperature, differential pressure, power
  • Temperature Range: 2x -100 to 400°C
  • Power Range: 0 to 500 W
  • Air Velocity Range: 0 to 10 m/s
  • Data Display: Digital display on front of instrumentation unit
  • PC Connectivity: Direct data transfer to PC (optional)
  • Calculated Parameters: Flow rate, Reynolds number, Nusselt number
  • Software: Optional DAQ software, ThermoFlux - 7078, LabVIEW-based

Experiments

  • Investigation of convection processes
  • Comparison of heat transfer for different heating elements
  • Comparison between different heating elements
  • Demonstration of the relationship between heat transfer, area of heat transfer and flow velocity (Nusselt)

Construction and Design

The Cross Flow Heat Exchanger ThermoFlux - 7078 is built around a vertical air duct as its primary structural element. A radial fan draws air through the duct and delivers a maximum flow rate of 13 m³/min at up to 430 Pa pressure difference. The duct cross-section measures 120 x 120 mm. Three interchangeable heater inserts are included: a single pipe, a pipe bundle, and a finned pipe bundle. Each insert is rated at 500 W. The pipe bundle insert can be positioned in different pipe rows to vary the cross flow heat exchanger flow arrangement during experiments. Electronic sensors integrated into the system measure temperature across two channels (range: -100 to 400°C), power (0 to 500 W), and air velocity (0 to 10 m/s). All sensor readings are shown on a digital display mounted on the front panel of the instrumentation unit. The unit also supports direct PC data transfer for further analysis.


Software

ThermoFlux - 7078 Software (Optional)

  • Developed in the National Instruments LabVIEW environment
  • Designed specifically for data acquisition with this apparatus
  • Records, stores, and calculates experimental results
  • Compatible with any Windows operating system
  • Electronic sensors are included when the software option is selected

Scope of Delivery

  • 1 experimental unit
  • 1 pipe bundle
  • 1 pipe element
  • 1 finned pipe bundle
  • 1 instructional manual

Specifications

Cross Flow Heat Exchanger ThermoFlux - 7078, Technical Specifications

Parameter Value
Flow Channel Cross-Section 120 x 120 mm
Radial Fan Max. Power Consumption 250 W
Radial Fan Max. Pressure Difference 430 Pa
Radial Fan Max. Flow Rate 13 m³/min
Temperature Measuring Range 2x -100 to 400°C
Power Measuring Range 0 to 500 W
Air Velocity Measuring Range 0 to 10 m/s

Technical Data

Flow Channel

Parameter Value
Cross-Section 120 x 120 mm

Radial Fan

Parameter Value
Max. Power Consumption 250 W
Max. Pressure Difference 430 Pa
Max. Flow Rate 13 m³/min

Heating Elements

Pipe

Parameter Value
Power 1x 500 W
Heating Surface 1x approx. 0.01 m²

Pipe Bundle

Parameter Value
Power 1x 500 W
Heating Surface 1x approx. 0.005 m²

Finned Pipe Bundle

Parameter Value
Power 1x 500 W
Heating Surface 1x approx. 0.014 m²

Measuring Ranges

Parameter Value
Temperature 2x -100 to 400°C
Power 0 to 500 W
Air Velocity 0 to 10 m/s

Buying Cross Flow Heat Exchanger: Distributor & Tender Guidance

Cross Flow Heat Exchanger is the product name procurement teams should use when searching, preparing a BOQ or comparing suppliers. A model reference identifies the proposed configuration; it should not replace the product name or the buyer’s required experiment. This equipment is considered for thermal-engineering teaching where learners measure heat, temperature, pressure, work, efficiency or energy balance.

What to include in the RFQ

State the product name, quantity, destination, curriculum or tender reference, and heat source, measurement points, operating range, instrumentation, utilities, safety provisions and experiment list. This lets the technical team respond against the intended use rather than guess from a model code.

How distributors should quote it

Keep Cross Flow Heat Exchanger as the BOQ line item. Add the proposed model, included accessories, documentation, packing and delivery basis as separate fields so the end buyer can verify the offer.

How to compare suppliers

Ask every bidder to state the measurable parameters, operating conditions and included instruments against the same syllabus outcome. Record exclusions and alternatives in writing before commercial comparison.

Why Buy From Scientico

🏭

In-House Manufacturer

Designed & built in our Ambala facility since 1993 — not a reseller. Full control over quality & customisation.

✅

Configuration Review

Specifications, documentation and options are confirmed against the selected model.

🌏

International Enquiries

Share your destination and procurement requirements for an export quotation.

📦

Quote-Based Supply

Send the model, quantity and delivery location for a tailored proposal.

🛠

Support Scope

Support and warranty terms are documented in the applicable quotation.

🎓

Built for Teaching

Designed around curriculum experiments with clear, repeatable, hands-on results.

Frequently Asked Questions

 

Q1: What heating elements are included with the Cross Flow Heat Exchanger ThermoFlux - 7078? Three interchangeable heating elements are included: a pipe, a pipe bundle, and a finned pipe bundle. Each operates at 500 W.

Q2: Can the airflow rate be adjusted during experiments? Yes. The radial fan allows variable airflow, with a maximum flow rate of 13 m³/min and a maximum pressure difference of 430 Pa.

Q3: Is the software included as standard? No. The ThermoFlux - 7078 DAQ software is optional. When selected, it includes the required electronic sensors and runs on any Windows operating system.

Q4: What parameters does the system calculate automatically? The unit calculates flow rate, Reynolds number, and Nusselt number from sensor data. It can also display temperature-time relationships and the dependence of Nusselt number on Reynolds number graphically.

Q5: Can the pipe bundle be repositioned within the duct? Yes. The heater insert for the pipe bundle can be positioned in different pipe rows within the duct to investigate the effect of flow position on heat transfer performance.

Related Guides & Resources

In-depth guides from Scientico on Thermodynamics lab setup, experiments and procurement.

Cross Flow Heat Exchanger | ThermoFlux - 7078

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Gas and oil burner trainerCombustion Laboratory Unit | ThermoFlux 12099Dew Point Hygrometer by Scientico IndiaDew Point Hygrometer | ThermoFlux – 7089Combustion Laboratory | ThermoFlux – 7081, model-specific lab equipment manufactured by Scientico IndiaCombustion Laboratory | ThermoFlux – 7081Common rail diesel trainerDiesel Engine Control System CR/EDC 15 Educational Trainer | ThermoFlux 2930Combined Convection and Radiation ThermoFlux – 7073, Scientico IndiaCombined Convection and Radiation ThermoFlux – 7073Educational Training Steam Boiler (100kg/h) | ThermoFlux – 7107, model-specific lab equipment manufactured by Scientico IndiaEducational Training Steam Boiler (100kg/h) | ThermoFlux – 7107Changes of States of Gases | ThermoFlux – 7019, model-specific lab equipment manufactured by Scientico IndiaChanges of States of Gases | ThermoFlux – 7019Engine Test Bed | ThermoFlux – 7080, model-specific lab equipment manufactured by Scientico IndiaEngine Test Bed | ThermoFlux – 7080