🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
Established 1993 Model-Specific Specifications Manufacturer-Direct Enquiries International Quotations Destination-Based Delivery Terms

Laminar Flow Reactor | ReaktiLabX – 12

The Laminar Flow Reactor ReaktiLabX – 12 studies continuous tubular reactor behavior under controlled laminar flow conditions. This Laminar Flow Reactor features a boro 3.3 glass tube, PMMA double jacket for heating and cooling, and a special inlet to reduce inlet length. A combined conductivity and temperature sensor tracks conversion and retention time distribution. It requires the Service Unit for Chemical Reactors for pump, tank, and heating circuit support.

The Laminar Flow Reactor ReaktiLabX – 12 is a continuous-operating tubular reactor that enables analysis of chemical reactions with typical retention time distribution and set flow conditions. This Laminar Flow Reactor mounts on the supply unit and is secured in place by two pins, connecting via quick-release connections. It develops laminar flow due to its dimensions and potential volume flows.

Product Overview

Laminar flow reactors are continuous-operating tubular reactors. They enable the analysis of chemical reactions with the typical retention time distribution and set flow conditions. This equipment series that enables research with various reactor types includes the Laminar Flow Reactor ReaktiLabX – 12. It is possible to analyze the operation and behavior of a reactor with laminar flow in continuous operation in conjunction with the supply unit ReaktiLabX 12.

The supply unit ReaktiLabX 12 is equipped with a heating water circuit, all required connections, pumps, reactant tanks, and a product tank. The reactors can also be cooled when used with a Water Chiller and the supply unit ReaktiLabX 12.

The supply unit is used to mount the CRE-3305-06, which is secured in place by two pins. The reactor may be quickly and easily connected to the supply unit using quick-release connections. Two pumps on the supply unit continuously feed the reactants into the reactor. Laminar flow develops due to the dimensions and potential volume flows. The reactants react to create the product. After a predetermined retention time through the upper end of the reactor, the combination of product and unconverted reactants exits. Through the use of an additional peristaltic pump, the mixture is moved into a tank of the supply unit.

By varying the speed of the pumps on the supply unit, the retention duration of the reactants in the reactor can be changed. By measuring the conductivity, the conversion in this Laminar Flow Reactor is identified. Included is a conductivity/temperature combination sensor. Temperature and conductivity are digitally shown on the supply unit’s switch cabinet. Additionally, data capture software can record and process the measured quantities (optional).

Laminar Flow Reactor ReaktiLabX – 12 — Technical Specifications

Specification Detail
Reactor Type Laminar flow reactor for connection to service unit CRE-3305
Pulsation Damping Air vessel for damping of pulsation
Mixing T-piece with nozzle for mixing the reactants
Inlet Design Special inlet for reducing the inlet length
Reactor Tube Straight glass tube with laminar flow
Jacket Transparent double jacket from PMMA for heating with ReaktiLabX 12 and cooling with lab water supply
Sensor For measuring the conductivity and temperature via ReaktiLabX 12
Temperature Control In the reactor via ReaktiLabX 12

Technical Data

Laminar Flow Reactor

Parameter Value
Inside diameter DN15
Height 600mm
Material Boro 3.3 glass

Water Bath

Parameter Value
Diameter 50mm
Material PMMA

Required

Parameter Value
Accessory Service Unit for Chemical Reactors ReaktiLabX 12

Key Features

  • Reactor Tube: straight glass, DN15 inside diameter, 600mm height, boro 3.3 glass material
  • Water Bath: PMMA, 50mm diameter
  • Pulsation Damping: air vessel included
  • Mixing: T-piece with nozzle
  • Special Inlet: reduces inlet length for improved flow development
  • Double Jacket: transparent PMMA, for heating and cooling via lab water supply
  • Sensor: combined conductivity and temperature measurement, digitally displayed
  • Optional Cooling: compatible with Water Chiller accessory
  • Flow Behavior: laminar flow developed through reactor dimensions and volume flow control, central to this Laminar Flow Reactor
  • Software: optional DAQ software for measurement and calculation

Experiments

  • Fundamentals of a saponification reaction
  • Continuous operation
  • Conversion depending on: retention time, temperature, concentration
  • Retention time distribution

Construction and Design

The Laminar Flow Reactor ReaktiLabX – 12 uses a straight glass tube reactor, DN15 inside diameter and 600mm in height, made of boro 3.3 glass. An air vessel dampens pulsation, while a T-piece with nozzle mixes the reactants before entry, aided by a special inlet designed to reduce inlet length. A transparent double jacket, made of PMMA with a 50mm diameter water bath, allows heating via the supply unit and cooling via the lab water supply, or optionally via a Water Chiller. The reactor is secured to the supply unit using two pins and connects via quick-release connections. Product and unconverted reactants exit through the upper end of the reactor after a predetermined retention time and are moved into a supply unit tank via an additional peristaltic pump. A combined conductivity and temperature sensor identifies conversion, with values digitally shown on the supply unit’s switch cabinet.

Software

Data capture software (optional) can record and process the measured quantities from this Laminar Flow Reactor.

Required Accessories

  • Service Unit for Chemical Reactors ReaktiLabX 12

FAQs

Q: What is the Laminar Flow Reactor ReaktiLabX – 12 used for?
A: It is used to analyze chemical reactions with typical retention time distribution and set flow conditions, studying saponification reaction fundamentals and conversion behavior.

Q: What are the dimensions of the reactor?
A: The reactor has an inside diameter of DN15 and a height of 600mm, made of boro 3.3 glass.

Q: How is laminar flow achieved in this reactor?
A: Laminar flow develops due to the reactor’s dimensions and controlled potential volume flows.

Q: Can the reactor be cooled during operation?
A: Yes, the reactor can be cooled using the transparent PMMA double jacket connected to the lab water supply, or optionally with a Water Chiller.

Q: What accessory is required to operate this reactor?
A: The Service Unit for Chemical Reactors ReaktiLabX 12 is required to operate this reactor, providing pumps, tanks, and the heating water circuit.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Laminar Flow Reactor | ReaktiLabX – 12 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send model, quantity, destination port and Incoterm. Proforma back with the full export documentation set listed.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender? A missing manufacturer authorisation form (MAF) gets a bid rejected before price is opened. Send the tender reference and closing date.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Gaseous Diffusion Apparatus | ReaktiLabX – 03Plug-Flow Reactor (PFR) | ReaktiLabX – 10Fluidized Bed Reactor | ReaktiLabX 19Service Unit for Chemical Reactors | ReaktiLabX – 07Fixed Bed Catalysis | ReaktiLabX – 05Stirred Tanks in Series | ReaktiLabX – 09Discontinuous Stirred Tank Reactor | ReaktiLabX – 17Trickle Bed Reactor | ReaktiLabX 15
📄 Download Datasheet