🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
✓ Established 1993 ✓ Model-Specific Specifications ✓ Manufacturer-Direct Enquiries ✓ International Quotations ✓ Destination-Based Delivery Terms

Fixed Bed Catalysis

Model ReaktiLabX - 05

The Fixed Bed Catalysis Apparatus ReaktiLabX – 05 studies the breakdown of saccharose into glucose and fructose using fixed bed catalysis. This Fixed Bed Catalysis Apparatus features three reactors for comparing chemical and biological catalysts under controlled temperature conditions. A peristaltic pump, regulated heating circuit, and optional photometer support quantity balance and yield determination. Optional DAQ software enables measurement and calculation of results.

The Fixed Bed Catalysis Apparatus ReaktiLabX – 05 enables chemical reactions to be accelerated by catalysts, studying the breakdown reaction of dissolved saccharose into glucose and fructose. This Fixed Bed Catalysis Apparatus moves the reactant from a tank into the reactor’s bottom via peristaltic pump, passing it through a permanent catalyst bed. It allows comparison of different catalysts using three reactors.

Product Overview

Chemical reactions can be enabled or accelerated by catalysts. The breakdown reaction of dissolved saccharose in glucose and fructose is the intended use of the Fixed Bed Catalysis Apparatus ReaktiLabX – 05.

The reactant (saccharose solution) is moved from a tank into the reactor’s bottom by a peristaltic pump. In the reactor, the catalyst appears as a permanent bed. The fixed bed is passed through by the saccharose solution. Saccharose breaks down into glucose and fructose during the process. The catalyst quickens the process, resulting in a higher yield of the finished product (a glucose/fructose mixture). In a tank, the product is collected.

It is possible to compare different catalysts using three reactors on this Fixed Bed Catalysis Apparatus. Exchanger resin is employed as the chemical catalyst. The biological catalyst invertase comes highly recommended. A controlled heating water circuit also makes it possible to examine how temperature affects the reaction.

A photometer that has been specially designed for the unit is provided to measure the amount of glucose present in the product. The photometer data are uploaded to a PC where software evaluates them (optional).

Fixed Bed Catalysis Apparatus ReaktiLabX – 05 — Technical Specifications

Specification Detail
Study Scope Investigation of catalytic reactions
Reactors 3, for comparison of various fixed bed catalysis
Reactant Delivery Peristaltic pump with adjustable speed to transport the reactant into the reactors
Analysis Drawing up a quantity balance, determining yield
Heating System Regulated heating circuit with water tank, heater, and pump to regulate the reactor temperatures
Containers 1 scaled container for reactant and product respectively
Product Analysis Photometer for analysis of the product (optional)

Technical Data

Reactors

Parameter Value
Diameter approx. 10mm
Height approx. 120mm

Peristaltic Pump

Parameter Value
Max. flow rate approx. 50mL/min

Heating Circuit Pump

Parameter Value
Max. flow rate 10L/min
Max. head 30m
Power consumption 120W

Heating Circuit

Parameter Value
Tank approx. 15L
Heater approx. max. 1kW

Tanks for Reactant and Product

Parameter Value
Capacity approx. 2000mL

Recommended Accessories

Parameter Value
Photometer Optional

Key Features

  • Reactors: 3, diameter approx. 10mm, height approx. 120mm, for catalyst comparison
  • Peristaltic Pump: adjustable speed, max. flow rate approx. 50mL/min
  • Heating Circuit: tank approx. 15L, heater approx. max. 1kW, pump rated 10L/min max. flow, 30m max. head, 120W power consumption
  • Reactant and Product Tanks: capacity approx. 2000mL, scaled for measurement
  • Catalyst Types: exchanger resin (chemical) and invertase (biological, highly recommended)
  • Temperature Study: controlled heating water circuit examines temperature effects on reaction
  • Product Analysis: optional photometer measures glucose content, with data upload to PC for software evaluation
  • Yield Determination: quantity balance and yield calculation central to studies on this Fixed Bed Catalysis Apparatus
  • Software: optional DAQ software for measurement and calculation

Experiments

  • Fundamentals of chemical catalysis
  • Fundamentals of enzymatic catalysis
  • Use of a photometric analyzer

Construction and Design

The Fixed Bed Catalysis Apparatus ReaktiLabX – 05 uses three reactors, each approximately 10mm in diameter and 120mm in height, allowing comparison of various fixed bed catalysts. A peristaltic pump, with adjustable speed and a maximum flow rate of approximately 50mL/min, transports the reactant (saccharose solution) from a tank into the reactor’s bottom. The catalyst forms a permanent fixed bed within the reactor, through which the saccharose solution passes and breaks down into glucose and fructose. A regulated heating circuit, with a tank of approximately 15L, a heater of approximately max. 1kW, and a pump rated 10L/min max. flow, 30m max. head, and 120W power consumption, regulates reactor temperatures. Scaled containers, approximately 2000mL capacity, hold the reactant and product respectively. An optional photometer measures glucose content in the product, with data uploadable to a PC for software evaluation.

Software

Software ReaktiLabX – 05 (optional). DAQ software specially designed in National Instrument™, LABVIEW™ environment to measure and calculate the results of the apparatus. The software is optional; a set of electronic sensors is included when the software is used. The software can be run with any Windows™ environment.

Scope of Delivery

  • 1 experimental setup
  • 1 instruction manual

Q: What is the Fixed Bed Catalysis Apparatus ReaktiLabX – 05 used for?
A: It is used to study the breakdown reaction of dissolved saccharose into glucose and fructose using fixed bed catalysis, comparing chemical and biological catalysts.

Q: How many reactors does the apparatus have?
A: The apparatus has 3 reactors, each approximately 10mm in diameter and 120mm in height, allowing comparison of various fixed bed catalysts.

Q: What catalysts are used with this apparatus?
A: Exchanger resin is used as the chemical catalyst, while invertase is recommended as the biological catalyst.

Q: How is glucose content measured in the product?
A: An optional photometer, specially designed for the unit, measures the amount of glucose present in the product, with data uploadable to a PC for software evaluation.

Q: How does temperature affect the reaction, and how is it controlled?
A: A regulated heating water circuit allows temperature effects on the reaction to be examined, with a heater rated approximately max. 1kW and a tank of approximately 15L.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Fixed Bed Catalysis | ReaktiLabX – 05 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send the model, quantity, destination and required Incoterm. We will confirm the supplied scope and available export documents.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender that requests a manufacturer authorisation form (MAF)? Send the tender reference, deadline and listed equipment so we can confirm what can be issued.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Chemical Reaction TechnologyModel ReaktiLabX - 05
🏭
Manufacturer DirectProduct-specific enquiry, not a generic catalogue
🌍
Destination MatchedConfiguration and delivery scope reviewed together
📄
Decision-Ready ReplyApplicable documentation confirmed before ordering
Product-specific enquiry

Get a quotation your team can evaluate

A bare price can hide configuration, accessories, voltage, documentation and delivery assumptions. Send the product and destination now so the quoted scope can be reviewed before a purchase decision.

Avoid the mismatchDo not approve a generic price that leaves supplied scope unclear.
Your product is attachedNo need to retype the model or copy the page URL.
Move toward an approvable quoteAdd the destination; quantity and tender details can follow.

No account is required. Organisation, quantity and tender details are optional. Include the country code so the team can reach you internationally.

1993
Manufacturing Since
Direct
Manufacturer Supply
Quote-based
International Orders
Model
ReaktiLabX - 05

Overview

The Fixed Bed Catalysis Apparatus ReaktiLabX - 05 enables chemical reactions to be accelerated by catalysts, studying the breakdown reaction of dissolved saccharose into glucose and fructose. This Fixed Bed Catalysis Apparatus moves the reactant from a tank into the reactor's bottom via peristaltic pump, passing it through a permanent catalyst bed. It allows comparison of different catalysts using three reactors.

Product Overview

Chemical reactions can be enabled or accelerated by catalysts. The breakdown reaction of dissolved saccharose in glucose and fructose is the intended use of the Fixed Bed Catalysis Apparatus ReaktiLabX - 05.

The reactant (saccharose solution) is moved from a tank into the reactor's bottom by a peristaltic pump. In the reactor, the catalyst appears as a permanent bed. The fixed bed is passed through by the saccharose solution. Saccharose breaks down into glucose and fructose during the process. The catalyst quickens the process, resulting in a higher yield of the finished product (a glucose/fructose mixture). In a tank, the product is collected.

It is possible to compare different catalysts using three reactors on this Fixed Bed Catalysis Apparatus. Exchanger resin is employed as the chemical catalyst. The biological catalyst invertase comes highly recommended. A controlled heating water circuit also makes it possible to examine how temperature affects the reaction.

A photometer that has been specially designed for the unit is provided to measure the amount of glucose present in the product. The photometer data are uploaded to a PC where software evaluates them (optional).

Key Features

Key Features

  • Reactors: 3, diameter approx. 10mm, height approx. 120mm, for catalyst comparison
  • Peristaltic Pump: adjustable speed, max. flow rate approx. 50mL/min
  • Heating Circuit: tank approx. 15L, heater approx. max. 1kW, pump rated 10L/min max. flow, 30m max. head, 120W power consumption
  • Reactant and Product Tanks: capacity approx. 2000mL, scaled for measurement
  • Catalyst Types: exchanger resin (chemical) and invertase (biological, highly recommended)
  • Temperature Study: controlled heating water circuit examines temperature effects on reaction
  • Product Analysis: optional photometer measures glucose content, with data upload to PC for software evaluation
  • Yield Determination: quantity balance and yield calculation central to studies on this Fixed Bed Catalysis Apparatus
  • Software: optional DAQ software for measurement and calculation

Experiments

  • Fundamentals of chemical catalysis
  • Fundamentals of enzymatic catalysis
  • Use of a photometric analyzer

Construction and Design

The Fixed Bed Catalysis Apparatus ReaktiLabX - 05 uses three reactors, each approximately 10mm in diameter and 120mm in height, allowing comparison of various fixed bed catalysts. A peristaltic pump, with adjustable speed and a maximum flow rate of approximately 50mL/min, transports the reactant (saccharose solution) from a tank into the reactor's bottom. The catalyst forms a permanent fixed bed within the reactor, through which the saccharose solution passes and breaks down into glucose and fructose. A regulated heating circuit, with a tank of approximately 15L, a heater of approximately max. 1kW, and a pump rated 10L/min max. flow, 30m max. head, and 120W power consumption, regulates reactor temperatures. Scaled containers, approximately 2000mL capacity, hold the reactant and product respectively. An optional photometer measures glucose content in the product, with data uploadable to a PC for software evaluation.

Software

Software ReaktiLabX - 05 (optional). DAQ software specially designed in National Instrument™, LABVIEW™ environment to measure and calculate the results of the apparatus. The software is optional; a set of electronic sensors is included when the software is used. The software can be run with any Windows™ environment.

Scope of Delivery

  • 1 experimental setup
  • 1 instruction manual

Specifications

Fixed Bed Catalysis Apparatus ReaktiLabX - 05 — Technical Specifications

Specification Detail
Study Scope Investigation of catalytic reactions
Reactors 3, for comparison of various fixed bed catalysis
Reactant Delivery Peristaltic pump with adjustable speed to transport the reactant into the reactors
Analysis Drawing up a quantity balance, determining yield
Heating System Regulated heating circuit with water tank, heater, and pump to regulate the reactor temperatures
Containers 1 scaled container for reactant and product respectively
Product Analysis Photometer for analysis of the product (optional)

Technical Data

Reactors

Parameter Value
Diameter approx. 10mm
Height approx. 120mm

Peristaltic Pump

Parameter Value
Max. flow rate approx. 50mL/min

Heating Circuit Pump

Parameter Value
Max. flow rate 10L/min
Max. head 30m
Power consumption 120W

Heating Circuit

Parameter Value
Tank approx. 15L
Heater approx. max. 1kW

Tanks for Reactant and Product

Parameter Value
Capacity approx. 2000mL

Recommended Accessories

Parameter Value
Photometer Optional

Buying Fixed Bed Catalysis: Distributor & Tender Guidance

Fixed Bed Catalysis is the product name procurement teams should use when searching, preparing a BOQ or comparing suppliers. A model reference identifies the proposed configuration; it should not replace the product name or the buyer’s required experiment. This equipment is considered for process-engineering practicals involving flow, level, pressure, temperature, reaction or industrial measurement and control.

What to include in the RFQ

State the product name, quantity, destination, curriculum or tender reference, and process variable, vessel or pipeline arrangement, sensors, controller, operating range, utilities, wetted materials and experiments. This lets the technical team respond against the intended use rather than guess from a model code.

How distributors should quote it

Keep Fixed Bed Catalysis as the BOQ line item. Add the proposed model, included accessories, documentation, packing and delivery basis as separate fields so the end buyer can verify the offer.

How to compare suppliers

Compare the physical process, control loop, instrumentation and supplied software as separate tender line items. Record exclusions and alternatives in writing before commercial comparison.

Why Buy From Scientico

🏭

In-House Manufacturer

Designed & built in our Ambala facility since 1993 — not a reseller. Full control over quality & customisation.

✅

Configuration Review

Specifications, documentation and options are confirmed against the selected model.

🌏

International Enquiries

Share your destination and procurement requirements for an export quotation.

📦

Quote-Based Supply

Send the model, quantity and delivery location for a tailored proposal.

🛠

Support Scope

Support and warranty terms are documented in the applicable quotation.

🎓

Built for Teaching

Designed around curriculum experiments with clear, repeatable, hands-on results.

Frequently Asked Questions

Q: What is the Fixed Bed Catalysis Apparatus ReaktiLabX - 05 used for? A: It is used to study the breakdown reaction of dissolved saccharose into glucose and fructose using fixed bed catalysis, comparing chemical and biological catalysts.

Q: How many reactors does the apparatus have? A: The apparatus has 3 reactors, each approximately 10mm in diameter and 120mm in height, allowing comparison of various fixed bed catalysts.

Q: What catalysts are used with this apparatus? A: Exchanger resin is used as the chemical catalyst, while invertase is recommended as the biological catalyst.

Q: How is glucose content measured in the product? A: An optional photometer, specially designed for the unit, measures the amount of glucose present in the product, with data uploadable to a PC for software evaluation.

Q: How does temperature affect the reaction, and how is it controlled? A: A regulated heating water circuit allows temperature effects on the reaction to be examined, with a heater rated approximately max. 1kW and a tank of approximately 15L.

Related Guides & Resources

In-depth guides from Scientico on Chemical Reaction Technology lab setup, experiments and procurement.

Fixed Bed Catalysis | ReaktiLabX - 05

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Discontinuous Stirred Tank Reactor by Scientico IndiaDiscontinuous Stirred Tank Reactor | ReaktiLabX – 17Fluidized Bed ReactorFluidized Bed Reactor | ReaktiLabX 19Diffusion in Liquids and Gases by Scientico IndiaDiffusion in Liquids and Gases | ReaktiLabX – 01Gaseous Diffusion Apparatus by Scientico IndiaGaseous Diffusion Apparatus | ReaktiLabX – 03Diffusion in Liquids by Scientico IndiaDiffusion in Liquids | ReaktiLabX – 02Laminar Flow Reactor by Scientico IndiaLaminar Flow Reactor | ReaktiLabX – 12Corrosion Study Unit by Scientico IndiaCorrosion Study Unit | ReaktiLabX – 04Plug-Flow Reactor (PFR) by Scientico IndiaPlug-Flow Reactor (PFR) | ReaktiLabX – 10
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.

Fixed Bed Catalysis | ReaktiLabX - 05