Temperature Measurement Bench | ThermoFlux – 7011
A CE-certified precision laboratory apparatus for engineering experimentation and technical education, manufactured by Scientico India to ISO 9001:2015 standards. Supplied with calibration certificate, operation manual, and complete export documentation. Designed for Thermodynamics Lab Equipment laboratories in engineering colleges and technical institutions.
Temperature Measurement Bench ThermoFlux 7011 is a complete, freestanding thermodynamics lab equipment unit engineered to help students investigate fundamental temperature sensing and measurement techniques. This Temperature Measurement Bench supports hands-on experimentation using thermocouples, resistance temperature detectors (RTD), thermistors, bimetallic indicators, mercury-in-glass thermometers, and psychrometers. Designed for engineering and science curricula, the ThermoFlux 7011 demonstrates temperature measurement across air, boiling water, ice-point, and wet/dry bulb conditions using a wide range of calibrated sensors.
Product Overview
The ThermoFlux 7011 is a self-contained thermodynamics lab equipment bench covering the complete fundamentals of temperature measurement. The unit provides multiple heat sources, a water heater, vacuum flask, and hot/cold air blower, enabling students to explore sensor behavior across a variety of thermal environments. Sensors include Pt100 RTD, Type K and Type J thermocouples, thermistor (NTC), bimetallic thermometer, vapor pressure thermometer, and a wet/dry bulb psychrometer for humidity determination. Calibration hardware consisting of precision resistors and a digital multimeter is included for accuracy verification. The apparatus supports investigation of thermoelectric effects (Seebeck and Peltier), reference junction behavior, intermediate metal and temperature laws, thermocouple series/parallel configurations, dynamic response, and surface temperature measurement. Optional DAQ software (TF-7011) developed in National Instruments LabVIEW environment enables real-time digital data acquisition and analysis on any Windows system, with electronic sensors supplied as part of the software package.
Request Specifications & Pricing
CE-certified, ISO 9001:2015 compliant. Supplied to universities and institutions in 60+ countries.
WhatsApp: +91 701-586-5225 | Email: [email protected]
View Quality Certifications | FAQ, Shipping, Warranty, Lead Time
Technical Specifications
| Field | Details |
|---|---|
| Product Name | Temperature Measurement Bench ThermoFlux 7011 |
| Model Reference | ThermoFlux, 7011 |
| Product Category | Thermodynamics Lab Equipment |
| Apparatus Type | Complete, freestanding bench unit |
| Primary Application | Fundamentals of temperature measurement using multiple sensor types |
| Heat Sources | Water Heater, Vacuum Flask, Air Blower (Hot/Cold) |
| Calibration Hardware | Precision resistors, Digital multimeter |
| Optional Software | TF-7011 (LabVIEW-based DAQ, Windows compatible) |
| Software Platform | National Instruments LabVIEW; Windows OS |
| Manufacturer | SCIENTICO, Ambala Cantt, India |
| Certifications | ISO 9001:2015, CE Marked |
Technical Data, Heat Sources
| Heat Source | Description |
|---|---|
| Water Heater | Immersion-type heater for hot water bath experiments |
| Vacuum Flask | Insulated flask for thermal storage and reference junction experiments |
| Air Blower | Hot/Cold air blower for air temperature and dynamic response studies |
Technical Data, Measuring Devices and Sensors
| Device / Sensor | Range / Type |
|---|---|
| RTD, Pt100 | Resistance Temperature Detector, PT100 class |
| Thermistor Sensor | NTC (Negative Temperature Coefficient) ceramic semiconductor type |
| Type K Thermocouple Sensor | Chromel-Alumel thermocouple sensor |
| Type J Thermocouple Sensor | Iron-Constantan thermocouple sensor |
| Type K Thermocouple Wires | Bare wire pair for circuit experiments |
| Type J Thermocouple Wires | Bare wire pair for circuit experiments |
| Glass Thermometer (Low Range) | -10°C to +110°C |
| Glass Thermometer (High Range) | -10°C to +360°C |
| Bimetallic Thermometer | 0°C to 120°C |
| Vapor Pressure Thermometer | 0°C to 120°C |
| Wet and Dry Bulb Thermometer (Hygrometer) | For relative humidity determination |
| Self-Adhesive Surface Thermometer, Range 2 | 0°C to 30°C |
| Self-Adhesive Surface Thermometer, Range 3 | 30°C to 60°C |
| Self-Adhesive Surface Thermometer, Range 4 | 60°C to 90°C |
Key Features
- Complete Temperature Measurement Bench: freestanding, self-contained thermodynamics lab equipment unit with all accessories included
- Sensor Coverage: Pt100 RTD, Type K thermocouple, Type J thermocouple, thermistor (NTC), bimetallic thermometer, vapor pressure thermometer, mercury-in-glass thermometers (-10°C to 110°C and -10°C to 360°C)
- Three Heat Sources: water heater, vacuum flask, and hot/cold air blower for diverse experimental setups
- Psychrometer Included: wet and dry bulb thermometer for relative humidity measurement
- Self-Adhesive Surface Thermometers: three ranges, 0°C to 30°C, 30°C to 60°C, and 60°C to 90°C
- Calibration Hardware: precision resistors and digital multimeter supplied for sensor accuracy verification
- Thermoelectric Experiments: supports Seebeck effect, Peltier effect, reference junctions, intermediate metals law, and intermediate temperatures law
- Thermocouple Wiring Configurations: series and parallel connections demonstrated
- Optional DAQ Software (TF-7011): National Instruments LabVIEW-based, compatible with all Windows environments
- ISO 9001:2015 certified manufacture; CE marked product
Experiments
- Measurement of water temperature in a hot water bath and vacuum flask using thermocouples, mercury-in-glass thermometer, RTD, bimetallic temperature indicator, and related sensors
- The Peltier thermoelectric effect
- The Seebeck thermoelectric effect
- Reference junctions
- The law of intermediate metals
- The law of intermediate temperatures
- Effect of lead resistance and meter impedance in thermocouple circuits
- Connection of thermocouples in parallel
- Connection of thermocouples in series
- Comparison of accuracy and methods of calibration
- Observation of dynamic response
- Surface temperature measurement
- Wet bulb and dry bulb temperature measurement
- Determination of relative humidity
Construction and Design
Temperature Measurement Bench ThermoFlux 7011 is built as a robust, freestanding thermodynamics lab equipment bench housing all heat sources, sensors, and calibration instruments in a single integrated structure. The unit accommodates three independent heat sources, a water heater for hot bath immersion tests, a vacuum flask for thermal insulation and reference junction work, and a hot/cold air blower for air temperature and dynamic response experiments. Each temperature measuring sensor is individually mounted and keyed for clear identification, enabling straightforward connection to the multimeter or optional DAQ interface. Thermocouple wires (Type K and Type J) are provided for student-assembled circuit experiments. Self-adhesive surface thermometers across three calibrated ranges allow non-invasive surface temperature measurement. The precision resistor set and included digital multimeter allow full calibration and impedance verification without additional equipment. All materials and construction conform to ISO 9001:2015 quality standards and meet CE marking requirements.
Software, TF-7011 (Optional)
DAQ software specially designed in the National Instruments LabVIEW environment to measure and calculate results of the apparatus. The software is optional; when selected, a set of electronic sensors is included. Compatible with any Windows operating system.
Scope of Delivery
- 1 x Experimental unit (Temperature Measurement Bench ThermoFlux 7011)
- 1 x Air blower
- 1 x Vacuum flask
- 1 x Water heater
- 1 x Set of temperature measurement accessories
- 1 x Set of connecting wires
- 1 x Digital multimeter
- 1 x Power cable
- 1 x Instructional manual
Q1: Which thermocouple types are included with the ThermoFlux 7011?
The apparatus includes both Type K (Chromel-Alumel) and Type J (Iron-Constantan) thermocouple sensors and their respective bare wire pairs, enabling comparison experiments and circuit configuration studies.
Q2: Can the Temperature Measurement Bench be used for humidity measurement?
Yes. The ThermoFlux 7011 includes a wet and dry bulb thermometer (psychrometer) enabling direct measurement for determination of relative humidity.
Q3: Is the DAQ software mandatory for operation?
No. The TF-7011 DAQ software is optional. The bench is fully functional as a standalone thermodynamics lab equipment unit using the included digital multimeter and sensors. The software package includes an additional set of electronic sensors when selected.
Q4: What is the temperature measurement range of the included sensors?
Sensor ranges span from -10°C to 360°C across the mercury-in-glass thermometers, 0°C to 120°C for the bimetallic and vapor pressure thermometers, 0°C to 90°C across the three self-adhesive surface thermometer strips, and the Pt100 RTD and thermocouples cover extended ranges per their standard specifications.
Q5: Does the ThermoFlux 7011 support surface temperature measurement?
Yes. Three self-adhesive surface thermometers are supplied: Range 2 (0°C to 30°C), Range 3 (30°C to 60°C), and Range 4 (60°C to 90°C), enabling non-contact surface temperature studies as a dedicated experiment.
Need Assistance? We're Here to Help!
Connect with our team for product specifications, pricing, and customized solutions for your institution or project.








