The Steam Power Plant with Steam Engine ThermoFlux – 7087 is a bench-scale laboratory trainer demonstrating the complete steam power cycle using a gas-fired boiler (NG/LPG, 6 kg/hr), a single-cylinder piston steam engine (max. 5 W, max. 1200 min⁻¹), a DC generator (max. 3.18 W at 6000 min⁻¹), and a water-cooled condenser. This steam power plant with steam engine measures temperature across eight channels (-100 to 400°C), pressure (0 to 6 bar), gas flow (up to 5 LPM), water flow (up to 7 LPM), voltage (0 to 10 VDC), and current (0 to 250 mA), with all values displayed on integrated unit displays. Safety is provided by a digital electronic pressure switch and a mechanical pressure safety valve rated at 4 bar. Optional LabVIEW-based DAQ software is available for Windows-based data acquisition.

The Steam Power Plant with Steam Engine ThermoFlux – 7087 is a laboratory trainer that demonstrates the complete steam power cycle using a gas-fired boiler, a single-cylinder piston steam engine, a DC generator, and a water-cooled condenser. This steam power plant with steam engine enables students to study steam generation, mechanical energy conversion, electricity generation, condensation, and boiler efficiency through a fully instrumented and safety-monitored bench-scale unit.


Product Overview

The Steam Power Plant with Steam Engine ThermoFlux – 7087 contains all main components of a steam power plant: a gas-fired steam boiler, a single-cylinder piston steam engine with a crank mechanism, a DC generator, a water-cooled condenser, a feed water tank, and a feed water pump. The gas-fired boiler operates on NG or LPG, generates steam at a capacity of 6 kg/hr, and is protected by a safety valve rated at 4 bar.

Steam from the boiler is supplied to the single-cylinder piston steam engine, where a piston and crank mechanism convert vapour pressure into mechanical energy. The maximum steam engine power output is 5 W at a maximum speed of 1200 min⁻¹. A DC motor acting as a generator converts the mechanical power into electricity, rated at a maximum of 3.18 W at 6000 min⁻¹. Light bulbs serve as electrical energy consumers. The exhaust steam is condensed in a water-cooled condenser.

Safety devices include a digital electronic pressure switch and a mechanical pressure safety valve, both monitoring boiler operation. Sensors measure temperature across eight channels (-100 to 400°C), pressure (0 to 6 bar), gas flow rate (up to 5 LPM), and water flow rate (up to 7 LPM). Generator voltage (0 to 10 VDC) and current (0 to 250 mA) are also measured and displayed. All measured values are readable on displays integrated into the experimental unit. Optional DAQ software enables PC-based data acquisition in a LabVIEW environment.

Steam Power Plant with Steam Engine ThermoFlux – 7087 — Technical Specifications

Parameter Value
Boiler Fuel NG/LPG
Boiler Steam Capacity 6 kg/hr
Boiler Safety Valve Rating 4 bar
Steam Engine Type Single-cylinder piston
Steam Engine Maximum Power 5 W
Steam Engine Maximum Speed 1200 min⁻¹
Generator Type DC motor
Generator Maximum Power 3.18 W at 6000 min⁻¹
Electrical Consumers Light bulbs
Condenser Type Water-cooled
Temperature Measuring Range 8x -100 to 400°C
Pressure Measuring Range 0 to 6 bar
Gas Flow Rate Range Up to 5 LPM
Water Flow Rate Range Up to 7 LPM
Voltage Measuring Range 0 to 10 VDC
Current Measuring Range 0 to 250 mA
Safety Device 1 Digital pressure switch (electronic)
Safety Device 2 Pressure safety valve (mechanical)

Technical Data

Steam Engine

Parameter Value
Type Single-cylinder piston
Maximum Power 5 W
Maximum Speed 1200 min⁻¹
Cylinders 1

Generator

Parameter Value
Type DC motor
Maximum Power 3.18 W at 6000 min⁻¹

Boiler

Parameter Value
Fuel NG/LPG
Steam Capacity 6 kg/hr
Safety Valve Rating 4 bar

Measuring Ranges

Parameter Value
Temperature 8x -100 to 400°C
Pressure 0 to 6 bar
Gas Flow Rate Up to 5 LPM
Water Flow Rate Up to 7 LPM
Voltage 0 to 10 VDC
Current 0 to 250 mA

Safety Devices

Parameter Value
Electronic Safety Digital pressure switch
Mechanical Safety Pressure safety valve

Key Features

  • Steam Power Plant with Steam Engine Configuration: Gas-fired boiler, single-cylinder piston steam engine, DC generator, water-cooled condenser, feed water tank, and feed water pump
  • Boiler Fuel: NG/LPG
  • Boiler Steam Capacity: 6 kg/hr
  • Boiler Safety Valve: 4 bar
  • Steam Engine: Single-cylinder piston, max. 5 W, max. 1200 min⁻¹
  • Generator: DC motor, max. 3.18 W at 6000 min⁻¹
  • Electrical Consumers: Light bulbs
  • Condenser: Water-cooled
  • Temperature Measurement: 8x channels, -100 to 400°C
  • Pressure Measurement: 0 to 6 bar
  • Gas Flow Rate: Up to 5 LPM
  • Water Flow Rate: Up to 7 LPM
  • Voltage Measurement: 0 to 10 VDC
  • Current Measurement: 0 to 250 mA
  • Safety Devices: Digital electronic pressure switch and mechanical pressure safety valve
  • Display: All measured values readable on integrated unit displays
  • Software: Optional LabVIEW-based DAQ software, Windows compatible

Experiments

  • Demonstration of the function of a steam engine
  • Familiarisation with the components of a steam power plant and how they interact
  • Recording the vapour pressure curve
  • Effect of re-evaporation and backfeed of cold water
  • Determining consumption, the amount of steam generated, boiler efficiency, and the capacity of the condenser

Construction and Design

The Steam Power Plant with Steam Engine ThermoFlux – 7087 is a bench-scale trainer integrating all main components of a complete steam power cycle. The gas-fired boiler operates on NG or LPG, generates steam at 6 kg/hr, and is protected by a mechanical safety valve rated at 4 bar and a digital electronic pressure switch. Steam is supplied to a single-cylinder piston steam engine where a piston and crank mechanism convert vapour pressure into mechanical energy at up to 5 W and 1200 min⁻¹. A DC motor acting as a generator produces up to 3.18 W at 6000 min⁻¹ from the mechanical output. Light bulbs serve as electrical consumers. Exhaust steam is condensed in a water-cooled condenser. A feed water tank and feed water pump return condensate to the boiler.

Eight temperature sensor channels cover -100 to 400°C across all relevant measurement points. Pressure is measured from 0 to 6 bar. Gas flow rate is measured up to 5 LPM and water flow rate up to 7 LPM. Generator voltage (0 to 10 VDC) and current (0 to 250 mA) are measured and displayed. This steam power plant with steam engine displays all measured values on integrated displays within the experimental unit, with optional PC-based DAQ software available for extended data acquisition and analysis.


Software

ThermoFlux – 7087 Software (Optional)

  • Developed in the National Instruments LabVIEW environment
  • Designed specifically for data acquisition with this apparatus
  • Measures, processes, and stores experimental results on a PC
  • A set of electronic sensors is included when the software option is selected
  • Compatible with any Windows operating system

Scope of Delivery

  • 1 experimental unit
  • 1 instructional manual

Q1: What are the main components of the Steam Power Plant with Steam Engine ThermoFlux – 7087?
The unit includes a gas-fired steam boiler (NG/LPG, 6 kg/hr steam capacity), a single-cylinder piston steam engine (max. 5 W, max. 1200 min⁻¹), a DC generator (max. 3.18 W at 6000 min⁻¹), a water-cooled condenser, a feed water tank, and a feed water pump. Light bulbs serve as electrical consumers.

Q2: What safety devices are fitted to this steam power plant with steam engine unit?
Two safety devices are fitted: a digital electronic pressure switch and a mechanical pressure safety valve. Both monitor boiler operation to ensure safe running conditions. The boiler safety valve is rated at 4 bar.

Q3: How is electricity generated in this unit?
The single-cylinder piston steam engine converts steam energy into mechanical energy via a piston and crank mechanism. A DC motor acting as a generator then converts this mechanical power into electricity, rated at a maximum of 3.18 W at 6000 min⁻¹. Light bulbs are connected as electrical consumers.

Q4: What parameters are measured and displayed on the unit?
The unit measures and displays temperature across eight channels (-100 to 400°C), pressure (0 to 6 bar), gas flow rate (up to 5 LPM), water flow rate (up to 7 LPM), generator voltage (0 to 10 VDC), and generator current (0 to 250 mA).

Q5: Is DAQ software included as standard?
No. The ThermoFlux – 7087 DAQ software is optional. When selected, it includes the required electronic sensors, processes and stores experimental data on a PC, and runs in a LabVIEW environment on any Windows operating system.

Explore Related Equipment

Discover more mechanical engineering lab equipment including testing systems, experimental setups, and training models designed for academic and industrial applications.

Testimonials

Scientico India delivered CE-certified laboratory equipment for our engineering programme on schedule. Documentation was complete and instruments were well calibrated.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Make An Enquiry