🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
✓ Established 1993 ✓ Model-Specific Specifications ✓ Manufacturer-Direct Enquiries ✓ International Quotations ✓ Destination-Based Delivery Terms

Young’s Modulus Apparatus | FortiTestX-43

The Young’s Modulus Apparatus FortiTestX-43 is a wall-mounted laboratory unit for investigating elastic elongation of metal wire specimens under direct tensile loading. This Young’s modulus apparatus supports experiments with steel, aluminium, brass, and copper wires (1000 mm length, 1 to 2 mm diameter), measuring elongation via a vernier gauge with a 100 mm range and 0.02 mm graduation. A traverse distributes load evenly from the weight set to the wire bottom ends, enabling systematic study of elongation as a function of load, diameter, and material. The unit supports direct determination and verification of the modulus of elasticity for all four wire materials.

The Young’s Modulus Apparatus FortiTestX-43 is a wall-mounted experimental unit for investigating the elastic elongation of metal wires under tensile loading. This Young’s modulus apparatus enables determination and verification of the modulus of elasticity for steel, aluminium, brass, and copper wire specimens, with elongation measured by a vernier gauge at 0.02 mm graduation. It covers the relationship between wire elongation, applied load, wire diameter, and material properties within a single compact wall-mounted setup.

Product Overview

The Young’s Modulus Apparatus FortiTestX-43 is fixed to a wall-mounted carrier from which wire specimens are suspended. The bottom ends of the wires are secured using two sliders. A traverse connects the wires at their lower ends and distributes applied load evenly across the specimens. Weights are placed on the traverse to load the wires in direct tension. Wire elongation resulting from the applied tensile force is measured using a moment lever fitted with a vernier gauge, providing a displacement range of 100 mm at 0.02 mm graduation. Wire specimens are available in four materials: steel, aluminium, brass, and copper. Each wire is 1000 mm in length with a diameter ranging from 1 to 2 mm. Experiments investigate elastic elongation as a function of applied load, wire diameter, and material, and enable direct determination and verification of the modulus of elasticity for each material. This Young’s modulus apparatus is suited to undergraduate engineering and materials science laboratory programmes requiring hands-on measurement of fundamental elastic material properties.

Young’s Modulus Apparatus FortiTestX-43, Technical Specifications

Parameter Detail
Model Reference FortiTestX-43
Category Strength of Materials and Structures
Mounting Type Wall-mounted carrier
Wire Length 1000 mm
Wire Diameter 1 to 2 mm
Wire Materials Steel, Aluminium, Brass, Copper
Load Application Direct load via traverse and weight set
Displacement Range 100 mm
Graduation 0.02 mm
Measuring Device Vernier gauge on moment lever
Wire Attachment Two sliders at bottom ends

Technical Data

Wire Specimens

Parameter Value
Wire Length 1000 mm
Wire Diameter 1 to 2 mm
Materials Steel, Copper, Brass, Aluminium

Displacement Measuring Device

Parameter Value
Type Vernier gauge
Displacement Range 100 mm
Graduation 0.02 mm

Weight Set

Weight Quantity
1 N hanger weight 1
1 kg weight 1
2 kg weights 4

Key Features

  • Wall Mounting: carrier fixed to wall, wire specimens suspended vertically for direct tensile loading
  • Wire Specimens: steel, aluminium, brass, and copper, each 1000 mm length, 1 to 2 mm diameter
  • Load Application: direct load via traverse connecting bottom wire ends, loaded by weight set
  • Elongation Measurement: vernier gauge on moment lever, 100 mm displacement range, 0.02 mm graduation
  • Wire Attachment: two sliders secure the bottom ends of the wire specimens to the traverse
  • Weight Set Included: 1x 1 N hanger, 1x 1 kg, 4x 2 kg
  • Young’s Modulus Coverage: this Young’s modulus apparatus supports determination and verification of modulus of elasticity for four materials
  • Experiment Variables: elongation measured as a function of load, wire diameter, and material
  • Load Type: direct tensile load applied evenly across wires via traverse

Experiments

  • Elastic elongation of metal wires subject to tensile force as a function of the load
  • Elastic elongation as a function of the diameter of the wire
  • Elastic elongation as a function of material: copper, aluminium, brass, and steel
  • Determination and checking of the modulus of elasticity

Construction and Design

The Young’s Modulus Apparatus FortiTestX-43 is mounted on a wall-fixed carrier from which wire specimens in steel, aluminium, brass, and copper are suspended vertically. Each wire is 1000 mm long with a diameter between 1 and 2 mm. The bottom ends of the wires are attached using two sliders that connect to a traverse. The traverse distributes the applied load evenly across the wire specimens and supports the weight set for direct tensile loading. A moment lever fitted with a vernier gauge measures elongation of the wires under load, with a displacement range of 100 mm and graduation of 0.02 mm. This Young’s modulus apparatus allows the effect of load magnitude, wire diameter, and material on elastic elongation to be systematically investigated, and enables direct calculation and verification of the modulus of elasticity from the measured data.

Scope of Delivery

Scope of delivery not specified in source data. Please confirm with SCIENTICO before publishing.

Q1: What wire materials are included with the Young’s Modulus Apparatus FortiTestX-43?
Four wire materials are provided: steel, aluminium, brass, and copper, each 1000 mm in length with a diameter between 1 and 2 mm.

Q2: How is wire elongation measured on this Young’s modulus apparatus?
Elongation is measured using a vernier gauge mounted on a moment lever. The measuring range is 100 mm with a graduation of 0.02 mm.

Q3: How are loads applied to the wire specimens?
Weights are placed on a traverse that connects the bottom ends of the wire specimens, applying a direct and evenly distributed tensile load.

Q4: What variables can be investigated with the FortiTestX-43?
Elastic elongation can be investigated as a function of applied load, wire diameter, and wire material. The modulus of elasticity can also be determined and verified experimentally for each material.

Q5: What weight values are included with the apparatus?
The unit includes 1x 1 N hanger weight, 1x 1 kg weight, and 4x 2 kg weights.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Young’s Modulus Apparatus | FortiTestX-43 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send model, quantity, destination port and Incoterm. Proforma back with the full export documentation set listed.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender? A missing manufacturer authorisation form (MAF) gets a bid rejected before price is opened. Send the tender reference and closing date.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Plan the experiment before confirming this machine

Use the selection hub to verify that this equipment matches the required learning outcome. Confirm the offered configuration, range, accessories, utilities and documentation from this product record and datasheet.

Choose by required outcomeYoung’s modulus measurement guideBrowse all Strength of Materials equipment
Strength of MaterialsModel FortiTestX-43
🏭
Manufacturer DirectProduct-specific enquiry, not a generic catalogue
🌍
Destination MatchedConfiguration and delivery scope reviewed together
📄
Decision-Ready ReplyApplicable documentation confirmed before ordering
Product-specific enquiry

Get a quotation your team can evaluate

A bare price can hide configuration, accessories, voltage, documentation and delivery assumptions. Send the product and destination now so the quoted scope can be reviewed before a purchase decision.

Avoid the mismatchDo not approve a generic price that leaves supplied scope unclear.
Your product is attachedNo need to retype the model or copy the page URL.
Move toward an approvable quoteAdd the destination; quantity and tender details can follow.

No account is required. Organisation, quantity and tender details are optional. Include the country code so the team can reach you internationally.

1993
Manufacturing Since
Direct
Manufacturer Supply
Quote-based
International Orders
Model
FortiTestX-43

Overview

The Young's Modulus Apparatus FortiTestX-43 is a wall-mounted experimental unit for investigating the elastic elongation of metal wires under tensile loading. This Young's modulus apparatus enables determination and verification of the modulus of elasticity for steel, aluminium, brass, and copper wire specimens, with elongation measured by a vernier gauge at 0.02 mm graduation. It covers the relationship between wire elongation, applied load, wire diameter, and material properties within a single compact wall-mounted setup.

Product Overview

The Young's Modulus Apparatus FortiTestX-43 is fixed to a wall-mounted carrier from which wire specimens are suspended. The bottom ends of the wires are secured using two sliders. A traverse connects the wires at their lower ends and distributes applied load evenly across the specimens. Weights are placed on the traverse to load the wires in direct tension. Wire elongation resulting from the applied tensile force is measured using a moment lever fitted with a vernier gauge, providing a displacement range of 100 mm at 0.02 mm graduation. Wire specimens are available in four materials: steel, aluminium, brass, and copper. Each wire is 1000 mm in length with a diameter ranging from 1 to 2 mm. Experiments investigate elastic elongation as a function of applied load, wire diameter, and material, and enable direct determination and verification of the modulus of elasticity for each material. This Young's modulus apparatus is suited to undergraduate engineering and materials science laboratory programmes requiring hands-on measurement of fundamental elastic material properties.

Key Features

Key Features

  • Wall Mounting: carrier fixed to wall, wire specimens suspended vertically for direct tensile loading
  • Wire Specimens: steel, aluminium, brass, and copper, each 1000 mm length, 1 to 2 mm diameter
  • Load Application: direct load via traverse connecting bottom wire ends, loaded by weight set
  • Elongation Measurement: vernier gauge on moment lever, 100 mm displacement range, 0.02 mm graduation
  • Wire Attachment: two sliders secure the bottom ends of the wire specimens to the traverse
  • Weight Set Included: 1x 1 N hanger, 1x 1 kg, 4x 2 kg
  • Young's Modulus Coverage: this Young's modulus apparatus supports determination and verification of modulus of elasticity for four materials
  • Experiment Variables: elongation measured as a function of load, wire diameter, and material
  • Load Type: direct tensile load applied evenly across wires via traverse

Experiments

  • Elastic elongation of metal wires subject to tensile force as a function of the load
  • Elastic elongation as a function of the diameter of the wire
  • Elastic elongation as a function of material: copper, aluminium, brass, and steel
  • Determination and checking of the modulus of elasticity

Construction and Design

The Young's Modulus Apparatus FortiTestX-43 is mounted on a wall-fixed carrier from which wire specimens in steel, aluminium, brass, and copper are suspended vertically. Each wire is 1000 mm long with a diameter between 1 and 2 mm. The bottom ends of the wires are attached using two sliders that connect to a traverse. The traverse distributes the applied load evenly across the wire specimens and supports the weight set for direct tensile loading. A moment lever fitted with a vernier gauge measures elongation of the wires under load, with a displacement range of 100 mm and graduation of 0.02 mm. This Young's modulus apparatus allows the effect of load magnitude, wire diameter, and material on elastic elongation to be systematically investigated, and enables direct calculation and verification of the modulus of elasticity from the measured data.

Scope of Delivery

Scope of delivery not specified in source data. Please confirm with SCIENTICO before publishing.

Specifications

Young's Modulus Apparatus FortiTestX-43, Technical Specifications

Parameter Detail
Model Reference FortiTestX-43
Category Strength of Materials and Structures
Mounting Type Wall-mounted carrier
Wire Length 1000 mm
Wire Diameter 1 to 2 mm
Wire Materials Steel, Aluminium, Brass, Copper
Load Application Direct load via traverse and weight set
Displacement Range 100 mm
Graduation 0.02 mm
Measuring Device Vernier gauge on moment lever
Wire Attachment Two sliders at bottom ends

Technical Data

Wire Specimens

Parameter Value
Wire Length 1000 mm
Wire Diameter 1 to 2 mm
Materials Steel, Copper, Brass, Aluminium

Displacement Measuring Device

Parameter Value
Type Vernier gauge
Displacement Range 100 mm
Graduation 0.02 mm

Weight Set

Weight Quantity
1 N hanger weight 1
1 kg weight 1
2 kg weights 4

Buying Young's Modulus Apparatus: Distributor & Tender Guidance

Young's Modulus Apparatus is the product name procurement teams should use when searching, preparing a BOQ or comparing suppliers. A model reference identifies the proposed configuration; it should not replace the product name or the buyer’s required experiment. This equipment is considered for mechanics-of-materials teaching where students apply load and measure stress, strain, deflection, hardness, impact or failure behaviour.

What to include in the RFQ

State the product name, quantity, destination, curriculum or tender reference, and loading method, capacity and resolution, specimen details, gauges or indicators, accessories, safety guards and test standards requested by the buyer. This lets the technical team respond against the intended use rather than guess from a model code.

How distributors should quote it

Keep Young's Modulus Apparatus as the BOQ line item. Add the proposed model, included accessories, documentation, packing and delivery basis as separate fields so the end buyer can verify the offer.

How to compare suppliers

Confirm capacity, specimen compatibility and measurement method line by line before treating two testing systems as equivalent. Record exclusions and alternatives in writing before commercial comparison.

Why Buy From Scientico

🏭

In-House Manufacturer

Designed & built in our Ambala facility since 1993 — not a reseller. Full control over quality & customisation.

✅

Configuration Review

Specifications, documentation and options are confirmed against the selected model.

🌏

International Enquiries

Share your destination and procurement requirements for an export quotation.

📦

Quote-Based Supply

Send the model, quantity and delivery location for a tailored proposal.

🛠

Support Scope

Support and warranty terms are documented in the applicable quotation.

🎓

Built for Teaching

Designed around curriculum experiments with clear, repeatable, hands-on results.

Frequently Asked Questions

Q1: What wire materials are included with the Young's Modulus Apparatus FortiTestX-43? Four wire materials are provided: steel, aluminium, brass, and copper, each 1000 mm in length with a diameter between 1 and 2 mm.

Q2: How is wire elongation measured on this Young's modulus apparatus? Elongation is measured using a vernier gauge mounted on a moment lever. The measuring range is 100 mm with a graduation of 0.02 mm.

Q3: How are loads applied to the wire specimens? Weights are placed on a traverse that connects the bottom ends of the wire specimens, applying a direct and evenly distributed tensile load.

Q4: What variables can be investigated with the FortiTestX-43? Elastic elongation can be investigated as a function of applied load, wire diameter, and wire material. The modulus of elasticity can also be determined and verified experimentally for each material.

Q5: What weight values are included with the apparatus? The unit includes 1x 1 N hanger weight, 1x 1 kg weight, and 4x 2 kg weights.

Young's Modulus Apparatus | FortiTestX-43

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Unsymmetrical Cantilever Apparatus | FortiTestX – 20, model-specific lab equipment manufactured by Scientico IndiaUnsymmetrical Cantilever Apparatus | FortiTestX – 20Buckling of Bars | FortiTestX-44, Scientico IndiaBuckling of Bars | FortiTestX-44Universal Testing Machine 50kN | FortiTestX – 40, model-specific lab equipment manufactured by Scientico IndiaUniversal Testing Machine 50kN | FortiTestX – 40Cam Analysis Machine | FortiTestX – 24, model-specific lab equipment manufactured by Scientico IndiaCam Analysis Machine | FortiTestX – 24Universal Testing Machine 30kN | FortiTestX – 16, model-specific lab equipment manufactured by Scientico IndiaUniversal Testing Machine 30kN | FortiTestX – 16Column Buckling | FortiTestX – 17, model-specific lab equipment manufactured by Scientico IndiaColumn Buckling | FortiTestX – 17Universal Hardness Tester, model-specific Lab Equipment by Scientico IndiaUniversal Hardness TesterCombined Bending and Torsion Apparatus | FortiTestX 04, Scientico IndiaCombined Bending and Torsion Apparatus | FortiTestX 04
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.

Young's Modulus Apparatus | FortiTestX-43