The Plate Type Heat Exchanger ThermoFlux – 7108/1 is a laboratory unit for studying heat transfer between hot and cold water through stainless steel sealed plates in parallel flow and counter flow configurations. This plate type heat exchanger provides 2 hot and cold input and output ports, a maximum flow of 30 m³/h, maximum working pressure of 30 bar, maximum working temperature of 120°C, and a heat transfer area of more than 0.21 m² across 10 or more plates. An anodized aluminium structure, HDF panel with front process diagram, pump for hot water circulation, cold water valve for flow selection, and temperature measurement at all four ports are included. External cold water supply (e.g., hydraulic bench) is required.

The Plate Type Heat Exchanger ThermoFlux – 7108/1 is a laboratory heat transfer unit for studying heat exchange between hot and cold water through a plate heat exchanger under parallel flow and counter flow configurations. This plate type heat exchanger features stainless steel sealed plates, an anodized aluminium structure, and a front panel with a process diagram matching the real unit layout. Hot and cold water temperatures are measured at both inlet and outlet, with a pump for hot water circulation and a cold water valve for flow type selection.


Product Overview

The ThermoFlux – 7108/1 is built around a plate heat exchanger formed by stainless steel sealed plates arranged in alternate channels. Hot and cold water pass through these alternate channels, transferring heat across the plate surfaces. The unit provides two input ports for hot and cold water and two output ports for hot and cold water, with a maximum flow capacity of 30 m³/h. Cold water is supplied from an external source such as a hydraulic bench. A cold water valve selects between parallel flow and counter flow configurations. A pump circulates hot water through the exchanger.

The plate heat exchanger operates across a maximum working pressure of 30 bar and a maximum working temperature of 120°C. Minimum working temperature is 4°C for water and -30°C for gases. The exchanger accommodates a maximum of 10 or more plates, an internal circuit capacity of more than 0.250 litres, an external circuit capacity of 0.250 litres, and a total heat transfer area of more than 0.21 m².

The unit structure is anodized aluminium with a panel in HDF sheet. All main water-contact elements are fabricated from stainless steel or brass. The front panel displays a process diagram with a layout corresponding directly to the positions of the real components on the unit. Instruments for control and monitoring are provided throughout.

Plate Type Heat Exchanger ThermoFlux – 7108/1 — Technical Specifications

Parameter Value
Model ThermoFlux – 7108/1
Heat Exchanger Type Plate heat exchanger
Plate Material Stainless steel, sealed
Flow Configurations Parallel flow and counter flow
Input Ports 2 (hot water and cold water)
Output Ports 2 (hot water and cold water)
Maximum Flow 30 m³/h
Maximum Working Pressure 30 bar
Maximum Working Temperature 120°C
Minimum Working Temperature (Water) 4°C
Minimum Working Temperature (Gases) -30°C
Maximum Number of Plates 10 or more
Internal Circuit Capacity More than 0.250 litres
External Circuit Capacity 0.250 litres
Heat Transfer Area More than 0.21 m²
Structure Material Anodized aluminium
Panel Material HDF sheet
Water-Contact Elements Stainless steel or brass
Hot Water Circulation Pump
Flow Type Selection Cold water valve
Cold Water Supply External source (e.g., hydraulic bench)
Front Panel Process diagram matching real unit layout
Temperature Measurement Hot and cold water at inlet and outlet

Technical Data

Plate Heat Exchanger

Parameter Value
Plate Material Stainless steel
Plate Sealing Sealed plates
Maximum Number of Plates 10 or more
Heat Transfer Area More than 0.21 m²
Internal Circuit Capacity More than 0.250 litres
External Circuit Capacity 0.250 litres

Operating Limits

Parameter Value
Maximum Flow 30 m³/h
Maximum Working Pressure 30 bar
Maximum Working Temperature 120°C
Minimum Working Temperature (Water) 4°C
Minimum Working Temperature (Gases) -30°C

Ports

Parameter Value
Input Ports 2 (hot water inlet, cold water inlet)
Output Ports 2 (hot water outlet, cold water outlet)

Structure and Panel

Parameter Value
Structure Material Anodized aluminium
Panel Material HDF sheet
Water-Contact Element Materials Stainless steel or brass
Front Panel Diagram Process diagram, layout matched to real unit

Circulation and Flow

Parameter Value
Hot Water Circulation Pump
Flow Type Selection Cold water valve
Cold Water Supply External source (e.g., hydraulic bench)
Flow Configurations Parallel flow and counter flow

Key Features

  • Plate Type Heat Exchanger Configuration: Stainless steel sealed plates in alternate channel arrangement, parallel flow and counter flow selectable
  • Ports: 2 input ports (hot and cold water), 2 output ports (hot and cold water)
  • Maximum Flow: 30 m³/h
  • Maximum Working Pressure: 30 bar
  • Maximum Working Temperature: 120°C
  • Minimum Working Temperature: 4°C for water, -30°C for gases
  • Plates: Maximum 10 or more stainless steel sealed plates
  • Heat Transfer Area: More than 0.21 m²
  • Internal Circuit Capacity: More than 0.250 litres
  • External Circuit Capacity: 0.250 litres
  • Structure: Anodized aluminium frame, HDF sheet panel
  • Water-Contact Elements: Stainless steel or brass throughout
  • Hot Water Circulation: Pump
  • Flow Selection: Cold water valve for parallel or counter flow
  • Cold Water Supply: External source, e.g., hydraulic bench
  • Front Panel: Process diagram with layout corresponding to real unit component positions
  • Temperature Measurement: Hot and cold water inlet and outlet temperatures

Experiments

  • Study of heat transfer between hot and cold water through alternate plate channels
  • Measurement of hot and cold water temperatures at inlet and outlet of the exchanger
  • Comparison of heat transfer performance under parallel flow configuration
  • Comparison of heat transfer performance under counter flow configuration

Construction and Design

The Plate Type Heat Exchanger ThermoFlux – 7108/1 is constructed on an anodized aluminium frame with a panel in HDF sheet. All main water-contact components are fabricated from stainless steel or brass. The heat exchanger itself is formed by stainless steel sealed plates arranged to create alternate channels through which hot and cold water flow independently. The exchanger accommodates a maximum of 10 or more plates, providing a heat transfer area of more than 0.21 m². The internal circuit capacity exceeds 0.250 litres and the external circuit capacity is 0.250 litres.

Two input ports accept hot and cold water, and two output ports discharge each stream after passing through the exchanger. A pump circulates hot water through the plate channels. Cold water is supplied from an external source such as a hydraulic bench. A cold water valve on the unit selects the flow configuration, switching between parallel flow and counter flow arrangements. Temperature measurement instruments monitor hot and cold water at both the inlet and outlet of this plate type heat exchanger, providing the data required for heat transfer calculations under each flow condition.

The front panel carries a process diagram with a component layout that corresponds directly to the physical arrangement of elements on the unit, aiding student comprehension of the flow path and measurement point locations. Operating limits are a maximum flow of 30 m³/h, maximum working pressure of 30 bar, maximum working temperature of 120°C, and minimum working temperatures of 4°C for water and -30°C for gases.


Required for Operation

  • External cold water supply (e.g., hydraulic bench)

Q1: What flow configurations can be studied with the ThermoFlux – 7108/1?
The unit supports both parallel flow and counter flow configurations. The cold water valve on the unit selects between the two arrangements, enabling direct comparison of heat transfer performance under each flow type.

Q2: What are the operating pressure and temperature limits of this plate type heat exchanger?
The maximum working pressure is 30 bar. The maximum working temperature is 120°C. The minimum working temperature is 4°C for water and -30°C for gases.

Q3: How many plates does the exchanger accommodate and what is the heat transfer area?
The exchanger accommodates a maximum of 10 or more stainless steel sealed plates. The total heat transfer area is more than 0.21 m².

Q4: What is the cold water supply requirement for the ThermoFlux – 7108/1?
Cold water is supplied from an external source such as a hydraulic bench. The cold water valve on the unit controls flow type selection between parallel and counter flow configurations.

Q5: What materials are used for water-contact components in this unit?
All main water-contact elements are fabricated from stainless steel or brass. The heat exchanger plates are stainless steel and are sealed. The unit structure is anodized aluminium with an HDF sheet panel.

Explore Related Equipment

Discover more mechanical engineering lab equipment including testing systems, experimental setups, and training models designed for academic and industrial applications.

Testimonials

Scientico India delivered CE-certified laboratory equipment for our engineering programme on schedule. Documentation was complete and instruments were well calibrated.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Make An Enquiry