🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
✓ Established 1993 ✓ Model-Specific Specifications ✓ Manufacturer-Direct Enquiries ✓ International Quotations ✓ Destination-Based Delivery Terms

Tablet Disintegration Test Apparatus Non-Digital | PMSC 04

The Tablet Disintegration Test Apparatus Non-Digital PMSC 04 is an IP-compliant disintegration tester. It features a 7.6 cm stroke at 30 strokes per minute, a glass tube and SS wire gauze basket, and a thermostatic hot plate holding 37 ±1°C with a 1000 ml beaker.

The Tablet Disintegration Test Apparatus Non-Digital PMSC 04 is a non-digital unit for IP disintegration testing of tablets. It features a basket with glass tubes and SS wire gauze, a thermostatic hot plate, and a 1000 ml beaker.

Product Overview

The PMSC 04 tablet disintegration test apparatus tests tablets as per IP requirements. The stroke length is 7.6 cm at 30 strokes per minute. The basket assembly uses glass tubes with SS wire gauze. A thermostatic hot plate maintains 37 ±1°C. The unit includes a 1000 ml beaker.

Tablet Disintegration Test Apparatus Non-Digital PMSC 04: Technical Specifications

Parameter Value
Standard IP
Stroke Length 7.6 cm
Stroke Rate 30 strokes per minute
Basket Glass tubes with SS wire gauze
Heating Thermostatic hot plate
Temperature 37 ±1°C
Beaker Capacity 1000 ml
Operation Non-digital

Technical Data

Basket Assembly:

  • Glass tubes
  • SS wire gauze

Heating:

  • Thermostatic hot plate
  • Temperature: 37 ±1°C

Motion:

  • Stroke length: 7.6 cm
  • Stroke rate: 30 strokes per minute

Vessel:

  • Beaker capacity: 1000 ml

Key Features

  • IP Compliant Testing: Disintegration testing as per IP requirements
  • Controlled Stroke: 7.6 cm stroke length at 30 strokes per minute
  • Glass and Wire Basket: Glass tubes with SS wire gauze
  • Thermostatic Control: Hot plate maintains 37 ±1°C
  • Non-Digital Operation: Simple mechanical operation
  • 1000 ml Beaker: Immersion vessel included

Experiments

  • Tablet disintegration time determination
  • Disintegration testing at 37 ±1°C
  • Disintegration testing per IP requirements

Construction and Design

The Tablet Disintegration Test Apparatus Non-Digital PMSC 04 uses a basket assembly of glass tubes fitted with SS wire gauze. The basket moves through a 7.6 cm stroke at 30 strokes per minute. A thermostatic hot plate holds the medium at 37 ±1°C. A 1000 ml beaker holds the test medium.

Scope of Delivery

  • 1 Non-digital tablet disintegration test apparatus
  • 1 Basket assembly with glass tubes and SS wire gauze
  • 1 Thermostatic hot plate
  • 1 1000 ml beaker

Q: What standard does the Tablet Disintegration Test Apparatus Non-Digital PMSC 04 follow?
A: It is designed for disintegration testing as per IP requirements.

Q: What stroke length and rate does the Tablet Disintegration Test Apparatus Non-Digital PMSC 04 use?
A: The stroke length is 7.6 cm at 30 strokes per minute.

Q: What temperature does the Tablet Disintegration Test Apparatus Non-Digital PMSC 04 maintain?
A: The thermostatic hot plate maintains 37 ±1°C.

Q: What is the basket made of?
A: The basket uses glass tubes with SS wire gauze.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Tablet Disintegration Test Apparatus Non-Digital | PMSC 04 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send model, quantity, destination port and Incoterm. Proforma back with the full export documentation set listed.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender? A missing manufacturer authorisation form (MAF) gets a bid rejected before price is opened. Send the tender reference and closing date.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Digital disintegration testerTablet Disintegration Test Apparatus IP Digital | PMSC 05Tablet Dissolution Test Apparatus 6 Station USP | PMSC 06Single punch tablet making machineRotary Tablet Punching Machine (Hand Operated) | SCI 741Two station dissolution testerTablet Dissolution Test Apparatus IP Digital Double Unit | PMSC 07Pharmacy Lab Equipment Manufacturer & Supplier – SCIENTICOIP digital dissolution apparatusTablet Dissolution Test Apparatus IP Digital Single Unit | PMSC 08Pfizer hardness testerPfizer Type Tablet Hardness Tester | PMSC 03Non-digital dissolution testerTablet Dissolution Test Apparatus Non-Digital | PMSC 09
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.

Tablet Disintegration Test Apparatus Non-Digital | PMSC 04