The Programmable Logic Control Trainer (Siemens Based) NexuMation-52 is an advanced PLC training platform for engineering laboratories, built around the Siemens CPU 1215C with 22 digital inputs, 18 digital outputs, 2 analog inputs, 2 analog outputs, and 125 KB program memory. This programmable logic control trainer supports Ladder, STL, and FBD programming, with built-in digital input simulators (8 toggle, 8 momentary), an analog input simulator, dual Ethernet PC interface, and fixed DC power supplies at 24 V, +12 V, -12 V, and 5 V. Two 40-pin IDC expansion connectors enable simultaneous dual optional module connection, and 13 optional control modules extend the platform to industrial automation applications including conveyor, elevator, robot, and HMI control.
The Programmable Logic Control Trainer (Siemens Based) NexuMation-52 is a high-capacity PLC training unit built around the Siemens CPU 1215C for advanced automation education in engineering laboratories. This programmable logic control trainer provides 22 digital inputs, 18 digital outputs, dual analog I/O, and dual 40-pin IDC expansion interfaces, supporting Ladder, STL, and FBD programming across a full range of structured automation experiments. Built-in digital and analog input simulators and dual Ethernet PC ports enable immediate, self-contained operation from commissioning.
Product Overview
The Programmable Logic Control Trainer (Siemens Based) NexuMation-52 provides a complete, ready-to-use advanced PLC training platform for engineering institutions requiring higher I/O capacity than standard PLC trainers. The core of the unit is the Siemens CPU 1215C, configured with 22 digital inputs, 18 digital outputs, 10 of which are 24 V DC (source), 2 analog voltage inputs, 2 analog voltage outputs, and 125 KB program memory. Three programming languages are supported: Ladder, STL, and FBD. Built-in digital input simulators provide 8 toggle inputs and 8 momentary inputs. An analog input simulator is also installed. Two analog voltage sources at +10 V each are provided. Fixed DC power supplies cover 24 V, +12 V, -12 V, and 5 V rails. PC connectivity is provided via two Ethernet ports. Two 40-pin IDC optional module interface connectors are installed for simultaneous dual-module expansion. This programmable logic control trainer ships complete with 2 mm patch cords, power cord, IDC cable, PLC programming cable, software CD, and experiment manual. Thirteen optional control modules extend the platform to traffic light, water level, temperature, conveyor, elevator, motor, robot, weight, HMI, and prismatic piece storage and sorting control applications.
Technical Specifications
| Parameter | Detail |
|---|---|
| Model Reference | NexuMation-52 |
| PLC Model | Siemens CPU 1215C |
| Digital Inputs | 22 |
| Digital Outputs | 18 (10 x 24 V DC Source confirmed) |
| Analog Inputs | 2 x Voltage Type |
| Analog Outputs | 2 x Voltage Type |
| Program Memory | 125 KB |
| Programming Languages | Ladder, STL, FBD |
| Digital Input Simulator | 8 x Toggle Inputs, 8 x Momentary Inputs |
| Analog Input Simulator | Installed |
| Analog Voltage Source | 2 x +10 V |
| Fixed DC Supply | 24 V, +12 V, -12 V, 5 V |
| PC Interface | Ethernet ports x 2 |
| Optional Module Interface | 2 x 40-pin IDC Connectors |
Technical Data
PLC Core
| Parameter | Value |
|---|---|
| PLC Model | Siemens CPU 1215C |
| Digital Inputs | 22 |
| Digital Outputs | 18 (10 x 24 V DC Source confirmed) |
| Analog Inputs | 2 x Voltage Type |
| Analog Outputs | 2 x Voltage Type |
| Program Memory | 125 KB |
| Programming Languages | Ladder, STL, FBD |
Input Simulators
| Parameter | Value |
|---|---|
| Toggle Inputs | 8 |
| Momentary Inputs | 8 |
| Analog Input Simulator | Installed |
Power Supplies
| Rail | Value |
|---|---|
| Fixed DC Supply 1 | 24 V |
| Fixed DC Supply 2 | +12 V |
| Fixed DC Supply 3 | -12 V |
| Fixed DC Supply 4 | 5 V |
| Analog Voltage Source | 2 x +10 V |
Interfaces
| Parameter | Value |
|---|---|
| PC Interface | Ethernet ports x 2 |
| Optional Module Interface | 2 x 40-pin IDC Connectors |
Key Features
- PLC Core: Siemens CPU 1215C with 125 KB program memory
- Digital I/O: 22 digital inputs, 18 digital outputs (10 x 24 V DC source confirmed)
- Analog I/O: 2 x voltage-type analog inputs, 2 x voltage-type analog outputs on this programmable logic control trainer
- Programming Languages: Ladder, STL, and FBD supported simultaneously
- Digital Input Simulators: 8 toggle inputs and 8 momentary inputs installed
- Analog Input Simulator: installed for signal simulation without external sources
- Analog Voltage Source: 2 x +10 V
- Fixed Power Supplies: 24 V, +12 V, -12 V, and 5 V DC rails installed
- PC Interface: dual Ethernet ports for programming and monitoring
- Dual Expansion Interface: 2 x 40-pin IDC connectors for simultaneous dual optional module connection
- Optional Modules: 13 control modules available including traffic light, conveyor, elevator, motor, robot, HMI, and weight control
Experiments
- Implementation of Logic Gates
- Implementation of Timers
- Implementation of 4-bit Digital to Analog Converter
- Implementation of UP/DOWN Counter
- Implementation of 4-bit Analog to Digital Converter
Construction and Design
The Programmable Logic Control Trainer (Siemens Based) NexuMation-52 is built around the Siemens CPU 1215C PLC module integrated within a self-contained training panel. All power supplies are installed internally, providing 24 V, +12 V, -12 V, and 5 V DC fixed rails alongside two analog voltage sources at +10 V each. Digital input simulation is handled by 8 toggle switches and 8 momentary pushbuttons installed on the panel, with an analog input simulator for voltage signal generation. Two Ethernet ports provide PC connectivity for programming and real-time monitoring. Two 40-pin IDC headers are mounted on the panel, allowing simultaneous connection of two optional expansion modules, distinguishing the NexuMation-52 from single-interface PLC trainers. This programmable logic control trainer supports all three IEC 61131-3 compliant programming languages available on the Siemens S7-1200 platform: Ladder, STL, and FBD. The unit ships ready for use with all accessories and experiment manual included. Thirteen optional control modules extend the platform to cover a comprehensive range of industrial automation scenarios.
Optional Modules
- Traffic Light Control by PLC
- Water Level Control by PLC
- Temperature Control by PLC
- Conveyor Control by PLC
- Elevator Control by PLC
- Motor Control by PLC
- Robot Control Module by PLC
- Module for Testing Selecting Pieces Control by PLC
- Weight Control Module by PLC
- Storage Control Module for Prismatic Pieces by PLC
- Conveyor Belt Control Module by PLC
- HMI Module
- Pushbutton Panel
Scope of Delivery
- 1 experimental unit
- 2 mm patch cords
- Power cord
- Experiment manual
- IDC cable
- PLC programming cable
- Software CD
Q1: Which PLC model is used in the Programmable Logic Control Trainer (Siemens Based) NexuMation-52?
The unit is built around the Siemens CPU 1215C, configured with 22 digital inputs, 18 digital outputs, 2 analog inputs, 2 analog outputs, and 125 KB program memory.
Q2: How does the NexuMation-52 differ from the NexuMation-51 in terms of I/O and expansion capacity?
The NexuMation-52 provides 22 digital inputs and 18 digital outputs compared to 14 inputs and 10 outputs on the NexuMation-51. It also features two 40-pin IDC expansion connectors instead of one, allowing simultaneous connection of two optional control modules.
Q3: What programming languages does this programmable logic control trainer support?
Three programming languages are supported: Ladder, STL (Statement List), and FBD (Function Block Diagram), consistent with IEC 61131-3 standards for the Siemens S7-1200 platform.
Q4: Are input simulators included, or must external signal sources be connected?
Both digital and analog input simulators are installed on the panel. Digital simulation uses 8 toggle inputs and 8 momentary inputs. An analog input simulator is also built in, enabling all experiments without external signal sources.
Q5: How is the NexuMation-52 connected to a PC for programming?
Two Ethernet ports provide PC connectivity. A PLC programming cable is included in the scope of delivery.
Need Assistance? We're Here to Help!