Nozzle Pressure Distribution

Model ThermoFlux – 7103

Nozzle Pressure Distribution ThermoFlux – 7103 is a laboratory apparatus for studying nozzle pressure distributionin convergent and de Laval (convergent-divergent) nozzles using air as the compressible working fluid.

Three interchangeable brass nozzles with pressure measurement points are included: one convergent nozzle and two de Laval nozzles with short and long extensions. Upstream pressure is adjustable via a compressed air regulator (0 to 8.6 bar, max. 10 bar supply). Back pressure is controlled by a needle valve on the flow meter. Air consumption is approximately 5 g/s.

Temperature is measured across -100 to 400°C. Pressure is recorded at 10 measuring points (-1 to 9 bar). Flow rate is measured up to 25 m³/h. Instruments include a manometer, digital temperature display (upstream and downstream), and rotameter. The unit demonstrates subsonic and supersonic flow, shock waves, and the choking effect at the critical pressure ratio.

Optional DAQ software in the National Instruments LabVIEW environment enables PC-based data acquisition on any Windows system. Supplied by SCIENTICO India with an instructional manual.

The Nozzle Pressure Distribution ThermoFlux – 7103 is a laboratory apparatus for measuring pressure curves in convergent and convergent-divergent (de Laval) nozzles and for studying the actual flow of compressible fluids. The unit demonstrates nozzle pressure distribution across subsonic, supersonic, and shock wave velocity ranges using air as the working fluid.

Three interchangeable brass nozzles are provided: one convergent nozzle and two de Laval nozzles with short and long nozzle extensions. The unit also demonstrates the choking effect, where the mass flow rate ceases to increase upon reaching the critical pressure ratio.


Product Overview

The Nozzle Pressure Distribution ThermoFlux – 7103 uses compressed air as the working compressible fluid. Air flows through a selected nozzle and is accelerated, with the nozzle pressure distribution recorded in the direction of flow over several measuring points. The air pressure upstream and downstream of the nozzle can be independently adjusted.

A compressed air regulator with a control range of 0 to 8.6 bar adjusts the upstream supply pressure. A needle valve on the flow meter adjusts the back pressure downstream of the nozzle. The unit accepts a maximum compressed air supply of 10 bar with an approximate air consumption of 5 g/s.

Three brass nozzles with pressure measurement points are included: one convergent nozzle for subsonic investigations, one de Laval nozzle with a short nozzle extension, and one de Laval nozzle with a long nozzle extension for supersonic and shock wave studies. Instruments include a manometer and a digital temperature display upstream and downstream of the nozzle, as well as a rotameter for flow measurement.

Temperature is measured across the range -100 to 400°C. Pressure is measured at 10 points across the range -1 to 9 bar. Flow rate is measurable up to 25 m³/h. Optional DAQ software in the National Instruments LabVIEW environment enables PC-based data recording, storage, and analysis.

Nozzle Pressure Distribution ThermoFlux – 7103: Technical Specifications

Parameter Value
Working Fluid Air (compressible)
Compressed Air Supply: Maximum 10 bar
Air Consumption Approx. 5 g/s
Compressed Air Regulator Control Range 0 to 8.6 bar
Back Pressure Control Needle valve on the flow meter
Nozzles Included 3 brass nozzles with pressure measurement points
Nozzle 1 Convergent nozzle
Nozzle 2 De Laval nozzle, short nozzle extension
Nozzle 3 De Laval nozzle, long nozzle extension
Nozzle Material Brass
Temperature Measurement Range -100 to 400°C
Pressure Measurement 10 x measuring points, range: -1 to 9 bar
Flow Rate Measurement Range Up to 25 m³/h
Instruments Manometer, digital temperature display (upstream and downstream), rotameter
Software Optional DAQ software (National Instruments LabVIEW environment)
Software Compatibility Any Windows environment

Technical Data

Air Supply

Parameter Value
Compressed Air: Maximum 10 bar
Air Consumption Approx. 5 g/s

Compressed Air Regulator

Parameter Value
Control Range 0 to 8.6 bar

Nozzles

Nozzle Detail
Material Brass (all 3 nozzles)
Nozzle 1 De Laval nozzle, short nozzle extension
Nozzle 2 De Laval nozzle, long nozzle extension
Nozzle 3 Convergent nozzle

Measuring Ranges

Parameter Range
Temperature -100 to 400°C
Pressure 10 x -1 to 9 bar
Flow Rate Up to 25 m³/h

Key Features

  • Apparatus Type: nozzle pressure distribution trainer for compressible fluid flow studies
  • Working Fluid: air
  • Nozzles Included: 3 interchangeable brass nozzles with pressure measurement points
  • Nozzle Types: 1 convergent nozzle, 1 de Laval nozzle (short extension), 1 de Laval nozzle (long extension)
  • Nozzle Material: brass
  • Compressed Air Supply: Maximum: 10 bar
  • Air Consumption: approx. 5 g/s
  • Compressed Air Regulator: control range 0 to 8.6 bar
  • Back Pressure Control: needle valve on the flow meter
  • Temperature Measurement Range: -100 to 400°C
  • Pressure Measurement: 10 measuring points, range: -1 to 9 bar
  • Flow Rate Measurement: up to 25 m³/h
  • Instruments: manometer, digital temperature display (upstream and downstream), rotameter
  • Velocity Ranges Studied: subsonic, supersonic, and shock wave
  • Choking Effect: demonstrated at critical pressure ratio
  • PC Data Transfer: optional direct transfer to PC
  • Software: optional DAQ software, National Instruments LabVIEW environment, Windows compatible

Experiments

  • Pressure curve in de Laval nozzles
    • Short nozzle extension
    • Long nozzle extension
  • Pressure curve in convergent nozzles
  • Connection between inlet pressure and mass flow rate, or exit pressure and mass flow rate
  • How pressure drop in the nozzle affects the temperature
  • Determining the critical pressure ratio (Laval pressure ratio)
  • Demonstration of the choking effect
  • Proof of shock waves

Construction and Design

The Nozzle Pressure Distribution ThermoFlux – 7103 is designed around a compressed air supply system with three interchangeable brass nozzles, each fitted with pressure measurement points along the flow direction.

Upstream pressure is set using a compressed air regulator with a control range of 0 to 8.6 bar. The maximum supply pressure is 10 bar, with an approximate air consumption of 5 g/s. A needle valve on the flow meter controls back pressure downstream of the nozzle. This dual adjustment capability enables independent setting of upstream and downstream pressures, which is essential for full nozzle pressure distribution characterisation across subsonic, supersonic, and shock wave regimes.

Three brass nozzles are supplied: one convergent nozzle for subsonic range investigations and two de Laval nozzles (combining convergent and divergent contours) with short and long nozzle extensions for supersonic and shock wave studies. All nozzles include pressure measurement points along the flow path, enabling the full pressure curve to be recorded in the direction of flow.

Instrumentation includes a manometer, a digital temperature display for upstream and downstream positions, and a rotameter for flow rate measurement. Temperature is measured across -100 to 400°C. Pressure is measured at 10 points over the range -1 to 9 bar. Flow rate is measurable up to 25 m³/h.


Software (Optional): ThermoFlux – 7103

DAQ software is specially designed in the National Instruments LabVIEW environment to measure and calculate results from the apparatus. The software is optional. When software is used, a set of electronic sensors is included. The software is compatible with any Windows environment.


Scope of Delivery

  • 1 experimental unit
  • 1 instructional manual

Optional Accessories

  • DAQ software package (ThermoFlux – 7103, National Instruments LabVIEW environment, Windows compatible), supplied with electronic sensors

Q: What nozzles are included with the Nozzle Pressure Distribution ThermoFlux – 7103?
A: Three interchangeable brass nozzles are included, each with pressure measurement points: one convergent nozzle for subsonic investigations, one de Laval nozzle with a short nozzle extension, and one de Laval nozzle with a long nozzle extension for supersonic and shock wave studies.

Q: What is the choking effect and how does this unit demonstrate it?
A: The choking effect occurs when the mass flow rate through a nozzle stops increasing upon reaching the critical pressure ratio (Laval pressure ratio). The unit demonstrates this by adjusting the upstream and downstream pressures using the compressed air regulator and needle valve, allowing the critical condition to be reached and observed directly.

Q: What are the compressed air supply requirements for this apparatus?
A: The unit requires a compressed air supply with a maximum pressure of 10 bar. Air consumption is approximately 5 g/s. The on-board compressed air regulator has a control range of 0 to 8.6 bar.

Q: What parameters are measured in the nozzle pressure distribution experiments?
A: The unit measures temperature (-100 to 400°C), pressure at 10 measuring points (range: -1 to 9 bar), and flow rate (up to 25 m³/h). Instruments include a manometer, digital temperature display upstream and downstream of the nozzle, and a rotameter.

Q: Is PC-based data acquisition available for the ThermoFlux – 7103?
A: Yes, as an optional feature. An optional DAQ software package developed in the National Instruments LabVIEW environment enables PC-based data recording and analysis. The software is compatible with any Windows environment and is supplied with a set of electronic sensors.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Nozzle Pressure Distribution | ThermoFlux – 7103 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send the model, quantity, destination and required Incoterm. We will confirm the supplied scope and available export documents.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender that requests a manufacturer authorisation form (MAF)? Send the tender reference, deadline and listed equipment so we can confirm what can be issued.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Thermodynamics Lab Equipment
🏭
Manufacturer DirectProduct-specific enquiry, not a generic catalogue
🌍
Destination MatchedConfiguration and delivery scope reviewed together
📄
Decision-Ready ReplyApplicable documentation confirmed before ordering
Product-specific enquiry

Get a quotation your team can evaluate

A bare price can hide configuration, accessories, voltage, documentation and delivery assumptions. Send the product and destination now so the quoted scope can be reviewed before a purchase decision.

Avoid the mismatchDo not approve a generic price that leaves supplied scope unclear.
Your product is attachedNo need to retype the model or copy the page URL.
Move toward an approvable quoteAdd the destination; quantity and tender details can follow.

No account is required. Organisation, quantity and tender details are optional. Include the country code so the team can reach you internationally.

1993
Manufacturing Since
Direct
Manufacturer Supply
Quote-based
International Orders
Model
Configuration

Overview

The Nozzle Pressure Distribution ThermoFlux – 7103 is a laboratory apparatus for measuring pressure curves in convergent and convergent-divergent (de Laval) nozzles and for studying the actual flow of compressible fluids. The unit demonstrates nozzle pressure distribution across subsonic, supersonic, and shock wave velocity ranges using air as the working fluid.

Three interchangeable brass nozzles are provided: one convergent nozzle and two de Laval nozzles with short and long nozzle extensions. The unit also demonstrates the choking effect, where the mass flow rate ceases to increase upon reaching the critical pressure ratio.


Product Overview

The Nozzle Pressure Distribution ThermoFlux – 7103 uses compressed air as the working compressible fluid. Air flows through a selected nozzle and is accelerated, with the nozzle pressure distribution recorded in the direction of flow over several measuring points. The air pressure upstream and downstream of the nozzle can be independently adjusted.

A compressed air regulator with a control range of 0 to 8.6 bar adjusts the upstream supply pressure. A needle valve on the flow meter adjusts the back pressure downstream of the nozzle. The unit accepts a maximum compressed air supply of 10 bar with an approximate air consumption of 5 g/s.

Three brass nozzles with pressure measurement points are included: one convergent nozzle for subsonic investigations, one de Laval nozzle with a short nozzle extension, and one de Laval nozzle with a long nozzle extension for supersonic and shock wave studies. Instruments include a manometer and a digital temperature display upstream and downstream of the nozzle, as well as a rotameter for flow measurement.

Temperature is measured across the range -100 to 400°C. Pressure is measured at 10 points across the range -1 to 9 bar. Flow rate is measurable up to 25 m³/h. Optional DAQ software in the National Instruments LabVIEW environment enables PC-based data recording, storage, and analysis.

Key Features

Key Features

  • Apparatus Type: nozzle pressure distribution trainer for compressible fluid flow studies
  • Working Fluid: air
  • Nozzles Included: 3 interchangeable brass nozzles with pressure measurement points
  • Nozzle Types: 1 convergent nozzle, 1 de Laval nozzle (short extension), 1 de Laval nozzle (long extension)
  • Nozzle Material: brass
  • Compressed Air Supply: Maximum: 10 bar
  • Air Consumption: approx. 5 g/s
  • Compressed Air Regulator: control range 0 to 8.6 bar
  • Back Pressure Control: needle valve on the flow meter
  • Temperature Measurement Range: -100 to 400°C
  • Pressure Measurement: 10 measuring points, range: -1 to 9 bar
  • Flow Rate Measurement: up to 25 m³/h
  • Instruments: manometer, digital temperature display (upstream and downstream), rotameter
  • Velocity Ranges Studied: subsonic, supersonic, and shock wave
  • Choking Effect: demonstrated at critical pressure ratio
  • PC Data Transfer: optional direct transfer to PC
  • Software: optional DAQ software, National Instruments LabVIEW environment, Windows compatible

Experiments

  • Pressure curve in de Laval nozzles
    • Short nozzle extension
    • Long nozzle extension
  • Pressure curve in convergent nozzles
  • Connection between inlet pressure and mass flow rate, or exit pressure and mass flow rate
  • How pressure drop in the nozzle affects the temperature
  • Determining the critical pressure ratio (Laval pressure ratio)
  • Demonstration of the choking effect
  • Proof of shock waves

Construction and Design

The Nozzle Pressure Distribution ThermoFlux – 7103 is designed around a compressed air supply system with three interchangeable brass nozzles, each fitted with pressure measurement points along the flow direction.

Upstream pressure is set using a compressed air regulator with a control range of 0 to 8.6 bar. The maximum supply pressure is 10 bar, with an approximate air consumption of 5 g/s. A needle valve on the flow meter controls back pressure downstream of the nozzle. This dual adjustment capability enables independent setting of upstream and downstream pressures, which is essential for full nozzle pressure distribution characterisation across subsonic, supersonic, and shock wave regimes.

Three brass nozzles are supplied: one convergent nozzle for subsonic range investigations and two de Laval nozzles (combining convergent and divergent contours) with short and long nozzle extensions for supersonic and shock wave studies. All nozzles include pressure measurement points along the flow path, enabling the full pressure curve to be recorded in the direction of flow.

Instrumentation includes a manometer, a digital temperature display for upstream and downstream positions, and a rotameter for flow rate measurement. Temperature is measured across -100 to 400°C. Pressure is measured at 10 points over the range -1 to 9 bar. Flow rate is measurable up to 25 m³/h.


Software (Optional): ThermoFlux – 7103

DAQ software is specially designed in the National Instruments LabVIEW environment to measure and calculate results from the apparatus. The software is optional. When software is used, a set of electronic sensors is included. The software is compatible with any Windows environment.


Scope of Delivery

  • 1 experimental unit
  • 1 instructional manual

Optional Accessories

  • DAQ software package (ThermoFlux – 7103, National Instruments LabVIEW environment, Windows compatible), supplied with electronic sensors

Specifications

Nozzle Pressure Distribution ThermoFlux – 7103: Technical Specifications

Parameter Value
Working Fluid Air (compressible)
Compressed Air Supply: Maximum 10 bar
Air Consumption Approx. 5 g/s
Compressed Air Regulator Control Range 0 to 8.6 bar
Back Pressure Control Needle valve on the flow meter
Nozzles Included 3 brass nozzles with pressure measurement points
Nozzle 1 Convergent nozzle
Nozzle 2 De Laval nozzle, short nozzle extension
Nozzle 3 De Laval nozzle, long nozzle extension
Nozzle Material Brass
Temperature Measurement Range -100 to 400°C
Pressure Measurement 10 x measuring points, range: -1 to 9 bar
Flow Rate Measurement Range Up to 25 m³/h
Instruments Manometer, digital temperature display (upstream and downstream), rotameter
Software Optional DAQ software (National Instruments LabVIEW environment)
Software Compatibility Any Windows environment

Technical Data

Air Supply

Parameter Value
Compressed Air: Maximum 10 bar
Air Consumption Approx. 5 g/s

Compressed Air Regulator

Parameter Value
Control Range 0 to 8.6 bar

Nozzles

Nozzle Detail
Material Brass (all 3 nozzles)
Nozzle 1 De Laval nozzle, short nozzle extension
Nozzle 2 De Laval nozzle, long nozzle extension
Nozzle 3 Convergent nozzle

Measuring Ranges

Parameter Range
Temperature -100 to 400°C
Pressure 10 x -1 to 9 bar
Flow Rate Up to 25 m³/h

Buying Nozzle Pressure Distribution: Distributor & Tender Guidance

Nozzle Pressure Distribution is the product name procurement teams should use when searching, preparing a BOQ or comparing suppliers. A model reference identifies the proposed configuration; it should not replace the product name or the buyer’s required experiment. This equipment is considered for thermal-engineering teaching where learners measure heat, temperature, pressure, work, efficiency or energy balance.

What to include in the RFQ

State the product name, quantity, destination, curriculum or tender reference, and heat source, measurement points, operating range, instrumentation, utilities, safety provisions and experiment list. This lets the technical team respond against the intended use rather than guess from a model code.

How distributors should quote it

Keep Nozzle Pressure Distribution as the BOQ line item. Add the proposed model, included accessories, documentation, packing and delivery basis as separate fields so the end buyer can verify the offer.

How to compare suppliers

Ask every bidder to state the measurable parameters, operating conditions and included instruments against the same syllabus outcome. Record exclusions and alternatives in writing before commercial comparison.

Why Buy From Scientico

🏭

In-House Manufacturer

Designed & built in our Ambala facility since 1993 — not a reseller. Full control over quality & customisation.

✅

Configuration Review

Specifications, documentation and options are confirmed against the selected model.

🌏

International Enquiries

Share your destination and procurement requirements for an export quotation.

📦

Quote-Based Supply

Send the model, quantity and delivery location for a tailored proposal.

🛠

Support Scope

Support and warranty terms are documented in the applicable quotation.

🎓

Built for Teaching

Designed around curriculum experiments with clear, repeatable, hands-on results.

Frequently Asked Questions

Q: What nozzles are included with the Nozzle Pressure Distribution ThermoFlux – 7103? A: Three interchangeable brass nozzles are included, each with pressure measurement points: one convergent nozzle for subsonic investigations, one de Laval nozzle with a short nozzle extension, and one de Laval nozzle with a long nozzle extension for supersonic and shock wave studies.

Q: What is the choking effect and how does this unit demonstrate it? A: The choking effect occurs when the mass flow rate through a nozzle stops increasing upon reaching the critical pressure ratio (Laval pressure ratio). The unit demonstrates this by adjusting the upstream and downstream pressures using the compressed air regulator and needle valve, allowing the critical condition to be reached and observed directly.

Q: What are the compressed air supply requirements for this apparatus? A: The unit requires a compressed air supply with a maximum pressure of 10 bar. Air consumption is approximately 5 g/s. The on-board compressed air regulator has a control range of 0 to 8.6 bar.

Q: What parameters are measured in the nozzle pressure distribution experiments? A: The unit measures temperature (-100 to 400°C), pressure at 10 measuring points (range: -1 to 9 bar), and flow rate (up to 25 m³/h). Instruments include a manometer, digital temperature display upstream and downstream of the nozzle, and a rotameter.

Q: Is PC-based data acquisition available for the ThermoFlux – 7103? A: Yes, as an optional feature. An optional DAQ software package developed in the National Instruments LabVIEW environment enables PC-based data recording and analysis. The software is compatible with any Windows environment and is supplied with a set of electronic sensors.

Related Guides & Resources

In-depth guides from Scientico on Thermodynamics lab setup, experiments and procurement.

Nozzle Pressure Distribution | ThermoFlux – 7103

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Nozzle Performance Study System  | ThermoFlux – 7094, model-specific lab equipment manufactured by Scientico IndiaNozzle Performance Study System | ThermoFlux – 7094Perfect Gas Law Apparatus ThermoFlux – 7077, Scientico IndiaPerfect Gas Law Apparatus | ThermoFlux – 7077Marcet Boiler | ThermoFlux – 7047, model-specific lab equipment manufactured by Scientico IndiaMarcet Boiler | ThermoFlux – 7047Plate Type Heat Exchanger | ThermoFlux – 7108/1, Scientico IndiaPlate Type Heat Exchanger | ThermoFlux – 7108/1Linear Heat Conduction Module | ThermoFlux – 7049/1, Scientico IndiaLinear Heat Conduction Module | ThermoFlux – 7049/1Pressure Measurement Bench by Scientico IndiaPressure Measurement Bench | ThermoFlux – 7015Linear and Radial Heat Transfer Unit | ThermoFlux – 7043, model-specific lab equipment manufactured by Scientico IndiaLinear and Radial Heat Transfer Unit | ThermoFlux – 7043Radiation Heat Transfer Module | ThermoFlux – 7049/3, Scientico IndiaRadiation Heat Transfer Module | ThermoFlux – 7049/3
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.

Nozzle Pressure Distribution | ThermoFlux – 7103