🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
✓ Established 1993 ✓ Model-Specific Specifications ✓ Manufacturer-Direct Enquiries ✓ International Quotations ✓ Destination-Based Delivery Terms

Nozzle Performance Study System

Model ThermoFlux - 7094

The Nozzle Performance Study System ThermoFlux – 7094 is a fully instrumented laboratory unit for studying nozzle performance as a kinetic energy producer and thrust producer using compressed air at up to 10 bar. It includes five interchangeable brass nozzles (four convergent-divergent, 2 mm diameter; one convergent, 2.19 mm diameter; lengths 3.6 mm to 15.8 mm), a baffle plate with adjustable distance, and a compressed air regulator (0 to 10 bar). This nozzle performance study system measures temperature (-100 to 400°C), pressure (2x 0 to 10 bar), mass flow (0.7 to 8.3 g/s), and force (0 to 5 N) via flexion pipe deformation. An optional air compressor (ThermoFlux – 7094) and LabVIEW-based DAQ software are available for continuous operation and PC-based data acquisition.

The Nozzle Performance Study System ThermoFlux – 7094 is a fully instrumented laboratory unit designed to enable students to study nozzle performance as both a kinetic energy producer and a thrust producer using compressed air. This nozzle performance study system includes five interchangeable brass nozzles, a baffle plate, force measurement via flexion pipe deformation, and digital instrumentation for pressure, temperature, mass flow, and force across a wide range of pressure ratios.


Product Overview

The Nozzle Performance Study System ThermoFlux – 7094 is supplied with compressed air from a separate compressor at a maximum inlet pressure of 10 bar and an air consumption of approximately 5 g/s. Five brass nozzles are included: four convergent-divergent nozzles and one convergent nozzle. The convergent-divergent nozzles have a throat diameter of 2 mm, and the convergent nozzle has a diameter of 2.19 mm. All nozzle lengths range from 3.6 mm to 15.8 mm. The nozzles are designed to operate at different theoretical expansion ratios and can be exchanged rapidly.

The unit measures both the reaction force (thrust) of the fluid at the nozzle and the action force at the baffle plate. Force measurement is performed by deformation of a flexion pipe, with a measuring range of 0 to 5 N. The distance between the baffle plate and the nozzle is adjustable. Air intake is adaptable according to the experiment layout. A compressed air regulator with a control range of 0 to 10 bar adjusts the pressure downstream of the nozzle. A needle valve on the flowmeter adjusts the back pressure.

Instrumentation includes a manometer and digital temperature display upstream and downstream of the nozzle, as well as a flowmeter. Measuring ranges cover temperature (-100 to 400°C), pressure (2x 0 to 10 bar), mass flow (0.7 to 8.3 g/s), and force (0 to 5 N). Operating conditions can be varied rapidly to generate results across a wide range of pressure ratios. Optional DAQ software enables PC-based data acquisition in a LabVIEW environment.

Nozzle Performance Study System ThermoFlux – 7094, Technical Specifications

Parameter Value
Compressed Air Supply Max. 10 bar
Air Consumption Approx. 5 g/s
Number of Nozzles 5 (brass)
Convergent-Divergent Nozzles 4
Convergent Nozzles 1
Convergent-Divergent Nozzle Diameter 2 mm
Convergent Nozzle Diameter 2.19 mm
Nozzle Length Range 3.6 mm to 15.8 mm
Compressed Air Regulator Control Range 0 to 10 bar
Force Measurement Method Deformation of flexion pipe
Temperature Measuring Range -100 to 400°C
Pressure Measuring Range 2x 0 to 10 bar
Mass Flow Measuring Range 0.7 to 8.3 g/s
Force Measuring Range 0 to 5 N
Baffle Plate Distance Adjustable
Air Intake Adaptable per experiment layout

Technical Data

Air Supply

Parameter Value
Compressed Air Supply Max. 10 bar
Air Consumption Approx. 5 g/s

Nozzles

Parameter Value
Total Number 5, brass
Convergent-Divergent 4
Convergent 1
Convergent-Divergent Diameter 2 mm
Convergent Diameter 2.19 mm
Length Range (All Nozzles) 3.6 mm to 15.8 mm

Compressed Air Regulator

Parameter Value
Control Range 0 to 10 bar

Measuring Ranges

Parameter Value
Temperature -100 to 400°C
Pressure 2x 0 to 10 bar
Mass Flow 0.7 to 8.3 g/s
Force 0 to 5 N

Force Measurement

Parameter Value
Method Deformation of flexion pipe
Measuring Range 0 to 5 N

Key Features

  • Nozzle Performance Study System Configuration: Fully instrumented unit for kinetic energy and thrust performance studies
  • Compressed Air Supply: Max. 10 bar, approx. 5 g/s air consumption
  • Nozzles Included: 5 brass nozzles, 4 convergent-divergent and 1 convergent, rapid interchange
  • Convergent-Divergent Nozzle Diameter: 2 mm throat
  • Convergent Nozzle Diameter: 2.19 mm
  • Nozzle Length Range: 3.6 mm to 15.8 mm across all nozzles
  • Nozzle Design: Different theoretical expansion ratios per nozzle contour
  • Baffle Plate: Included, with adjustable distance from nozzle
  • Force Measurement: Flexion pipe deformation, reaction and action force, 0 to 5 N
  • Back Pressure Adjustment: Needle valve on flowmeter
  • Compressed Air Regulator: Control range 0 to 10 bar, downstream pressure adjustment
  • Air Intake: Adaptable per experiment layout
  • Temperature Measurement: Digital display, upstream and downstream of nozzle, -100 to 400°C
  • Pressure Measurement: Manometer upstream and downstream, 2x 0 to 10 bar
  • Mass Flow Measurement: Flowmeter, 0.7 to 8.3 g/s
  • Optional Accessory: Air compressor suitable for continuous operation, ThermoFlux – 7094
  • Software: Optional LabVIEW-based DAQ software, Windows compatible

Experiments

  • Determining the critical pressure ratio
  • Measurement of the reaction or action force of the flowing fluid
  • Determine nozzle efficiency by thrust
  • Measuring reaction force (thrust) of the fluid at the nozzle
  • Measuring action force of the fluid at the baffle plate
  • Effect of inlet and outlet pressure ratio on mass flow and pressure distribution in the nozzle
  • Study of nozzle performance as a kinetic energy producer
  • Study of nozzle performance as a thrust producer

Construction and Design

The Nozzle Performance Study System ThermoFlux – 7094 is built around a compressed air supply circuit with an inlet pressure of up to 10 bar and an air consumption of approximately 5 g/s. Five interchangeable brass nozzles are provided: four convergent-divergent nozzles with a 2 mm throat diameter and one convergent nozzle with a diameter of 2.19 mm. All nozzles range in length from 3.6 mm to 15.8 mm and are designed for different theoretical expansion ratios. Nozzle exchange is rapid, and air intake is adaptable according to the experiment layout.

A compressed air regulator with a control range of 0 to 10 bar adjusts downstream pressure. A needle valve on the flowmeter adjusts back pressure. A baffle plate is included, and its distance from the nozzle is adjustable for action force measurement. Reaction force (thrust) at the nozzle and action force at the baffle plate are both measured by deformation of a flexion pipe, with a range of 0 to 5 N. A manometer and digital temperature display are installed upstream and downstream of the nozzle. A flowmeter measures mass flow from 0.7 to 8.3 g/s. This nozzle performance study system covers pressure measurement across two channels (0 to 10 bar each) and temperature measurement from -100 to 400°C. Optional DAQ software connects to a PC for data acquisition and processing.


Software

ThermoFlux – 7094 Software (Optional)

  • Developed in the National Instruments LabVIEW environment
  • Designed specifically for data acquisition with this apparatus
  • Measures, processes, and stores experimental results on a PC
  • A set of electronic sensors is included when the software option is selected
  • Compatible with any Windows operating system

Scope of Delivery

  • 1 experimental unit
  • 1 set of nozzles
  • 1 set of hoses
  • 1 instruction manual

Optional Accessories

Item Model
Air Compressor for Continuous Operation ThermoFlux – 7094

Q1: How many nozzles are included with the Nozzle Performance Study System ThermoFlux – 7094?
Five brass nozzles are included: four convergent-divergent nozzles with a 2 mm throat diameter and one convergent nozzle with a diameter of 2.19 mm. All nozzles range in length from 3.6 mm to 15.8 mm and can be exchanged rapidly.

Q2: How is force measured in this nozzle performance study system?
Both reaction force (thrust) at the nozzle and action force at the baffle plate are measured by deformation of a flexion pipe. The measuring range is 0 to 5 N.

Q3: How is back pressure adjusted during experiments?
Back pressure is adjusted using a needle valve on the flowmeter. A compressed air regulator with a control range of 0 to 10 bar also adjusts the pressure downstream of the nozzle.

Q4: What parameters does the unit measure?
The unit measures temperature (-100 to 400°C), pressure at two points (0 to 10 bar each), mass flow (0.7 to 8.3 g/s), and force (0 to 5 N) using a manometer, digital temperature display, flowmeter, and flexion pipe force measurement system.

Q5: Is a compressor included with the unit?
No. Compressed air is supplied from a separate compressor. An optional air compressor suitable for continuous operation (ThermoFlux – 7094) is available as an accessory.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Nozzle Performance Study System | ThermoFlux – 7094 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send the model, quantity, destination and required Incoterm. We will confirm the supplied scope and available export documents.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender that requests a manufacturer authorisation form (MAF)? Send the tender reference, deadline and listed equipment so we can confirm what can be issued.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Thermodynamics Lab EquipmentModel ThermoFlux - 7094
🏭
Manufacturer DirectProduct-specific enquiry, not a generic catalogue
🌍
Destination MatchedConfiguration and delivery scope reviewed together
📄
Decision-Ready ReplyApplicable documentation confirmed before ordering
Product-specific enquiry

Get a quotation your team can evaluate

A bare price can hide configuration, accessories, voltage, documentation and delivery assumptions. Send the product and destination now so the quoted scope can be reviewed before a purchase decision.

Avoid the mismatchDo not approve a generic price that leaves supplied scope unclear.
Your product is attachedNo need to retype the model or copy the page URL.
Move toward an approvable quoteAdd the destination; quantity and tender details can follow.

No account is required. Organisation, quantity and tender details are optional. Include the country code so the team can reach you internationally.

1993
Manufacturing Since
Direct
Manufacturer Supply
Quote-based
International Orders
Model
ThermoFlux - 7094

Overview

The Nozzle Performance Study System ThermoFlux - 7094 is a fully instrumented laboratory unit designed to enable students to study nozzle performance as both a kinetic energy producer and a thrust producer using compressed air. This nozzle performance study system includes five interchangeable brass nozzles, a baffle plate, force measurement via flexion pipe deformation, and digital instrumentation for pressure, temperature, mass flow, and force across a wide range of pressure ratios.


Product Overview

The Nozzle Performance Study System ThermoFlux - 7094 is supplied with compressed air from a separate compressor at a maximum inlet pressure of 10 bar and an air consumption of approximately 5 g/s. Five brass nozzles are included: four convergent-divergent nozzles and one convergent nozzle. The convergent-divergent nozzles have a throat diameter of 2 mm, and the convergent nozzle has a diameter of 2.19 mm. All nozzle lengths range from 3.6 mm to 15.8 mm. The nozzles are designed to operate at different theoretical expansion ratios and can be exchanged rapidly.

The unit measures both the reaction force (thrust) of the fluid at the nozzle and the action force at the baffle plate. Force measurement is performed by deformation of a flexion pipe, with a measuring range of 0 to 5 N. The distance between the baffle plate and the nozzle is adjustable. Air intake is adaptable according to the experiment layout. A compressed air regulator with a control range of 0 to 10 bar adjusts the pressure downstream of the nozzle. A needle valve on the flowmeter adjusts the back pressure.

Instrumentation includes a manometer and digital temperature display upstream and downstream of the nozzle, as well as a flowmeter. Measuring ranges cover temperature (-100 to 400°C), pressure (2x 0 to 10 bar), mass flow (0.7 to 8.3 g/s), and force (0 to 5 N). Operating conditions can be varied rapidly to generate results across a wide range of pressure ratios. Optional DAQ software enables PC-based data acquisition in a LabVIEW environment.

Key Features

Key Features

  • Nozzle Performance Study System Configuration: Fully instrumented unit for kinetic energy and thrust performance studies
  • Compressed Air Supply: Max. 10 bar, approx. 5 g/s air consumption
  • Nozzles Included: 5 brass nozzles, 4 convergent-divergent and 1 convergent, rapid interchange
  • Convergent-Divergent Nozzle Diameter: 2 mm throat
  • Convergent Nozzle Diameter: 2.19 mm
  • Nozzle Length Range: 3.6 mm to 15.8 mm across all nozzles
  • Nozzle Design: Different theoretical expansion ratios per nozzle contour
  • Baffle Plate: Included, with adjustable distance from nozzle
  • Force Measurement: Flexion pipe deformation, reaction and action force, 0 to 5 N
  • Back Pressure Adjustment: Needle valve on flowmeter
  • Compressed Air Regulator: Control range 0 to 10 bar, downstream pressure adjustment
  • Air Intake: Adaptable per experiment layout
  • Temperature Measurement: Digital display, upstream and downstream of nozzle, -100 to 400°C
  • Pressure Measurement: Manometer upstream and downstream, 2x 0 to 10 bar
  • Mass Flow Measurement: Flowmeter, 0.7 to 8.3 g/s
  • Optional Accessory: Air compressor suitable for continuous operation, ThermoFlux - 7094
  • Software: Optional LabVIEW-based DAQ software, Windows compatible

Experiments

  • Determining the critical pressure ratio
  • Measurement of the reaction or action force of the flowing fluid
  • Determine nozzle efficiency by thrust
  • Measuring reaction force (thrust) of the fluid at the nozzle
  • Measuring action force of the fluid at the baffle plate
  • Effect of inlet and outlet pressure ratio on mass flow and pressure distribution in the nozzle
  • Study of nozzle performance as a kinetic energy producer
  • Study of nozzle performance as a thrust producer

Construction and Design

The Nozzle Performance Study System ThermoFlux - 7094 is built around a compressed air supply circuit with an inlet pressure of up to 10 bar and an air consumption of approximately 5 g/s. Five interchangeable brass nozzles are provided: four convergent-divergent nozzles with a 2 mm throat diameter and one convergent nozzle with a diameter of 2.19 mm. All nozzles range in length from 3.6 mm to 15.8 mm and are designed for different theoretical expansion ratios. Nozzle exchange is rapid, and air intake is adaptable according to the experiment layout.

A compressed air regulator with a control range of 0 to 10 bar adjusts downstream pressure. A needle valve on the flowmeter adjusts back pressure. A baffle plate is included, and its distance from the nozzle is adjustable for action force measurement. Reaction force (thrust) at the nozzle and action force at the baffle plate are both measured by deformation of a flexion pipe, with a range of 0 to 5 N. A manometer and digital temperature display are installed upstream and downstream of the nozzle. A flowmeter measures mass flow from 0.7 to 8.3 g/s. This nozzle performance study system covers pressure measurement across two channels (0 to 10 bar each) and temperature measurement from -100 to 400°C. Optional DAQ software connects to a PC for data acquisition and processing.


Software

ThermoFlux - 7094 Software (Optional)

  • Developed in the National Instruments LabVIEW environment
  • Designed specifically for data acquisition with this apparatus
  • Measures, processes, and stores experimental results on a PC
  • A set of electronic sensors is included when the software option is selected
  • Compatible with any Windows operating system

Scope of Delivery

  • 1 experimental unit
  • 1 set of nozzles
  • 1 set of hoses
  • 1 instruction manual

Optional Accessories

Item Model
Air Compressor for Continuous Operation ThermoFlux - 7094

Specifications

Nozzle Performance Study System ThermoFlux - 7094, Technical Specifications

Parameter Value
Compressed Air Supply Max. 10 bar
Air Consumption Approx. 5 g/s
Number of Nozzles 5 (brass)
Convergent-Divergent Nozzles 4
Convergent Nozzles 1
Convergent-Divergent Nozzle Diameter 2 mm
Convergent Nozzle Diameter 2.19 mm
Nozzle Length Range 3.6 mm to 15.8 mm
Compressed Air Regulator Control Range 0 to 10 bar
Force Measurement Method Deformation of flexion pipe
Temperature Measuring Range -100 to 400°C
Pressure Measuring Range 2x 0 to 10 bar
Mass Flow Measuring Range 0.7 to 8.3 g/s
Force Measuring Range 0 to 5 N
Baffle Plate Distance Adjustable
Air Intake Adaptable per experiment layout

Technical Data

Air Supply

Parameter Value
Compressed Air Supply Max. 10 bar
Air Consumption Approx. 5 g/s

Nozzles

Parameter Value
Total Number 5, brass
Convergent-Divergent 4
Convergent 1
Convergent-Divergent Diameter 2 mm
Convergent Diameter 2.19 mm
Length Range (All Nozzles) 3.6 mm to 15.8 mm

Compressed Air Regulator

Parameter Value
Control Range 0 to 10 bar

Measuring Ranges

Parameter Value
Temperature -100 to 400°C
Pressure 2x 0 to 10 bar
Mass Flow 0.7 to 8.3 g/s
Force 0 to 5 N

Force Measurement

Parameter Value
Method Deformation of flexion pipe
Measuring Range 0 to 5 N

Buying Nozzle Performance Study System: Distributor & Tender Guidance

Nozzle Performance Study System is the product name procurement teams should use when searching, preparing a BOQ or comparing suppliers. A model reference identifies the proposed configuration; it should not replace the product name or the buyer’s required experiment. This equipment is considered for thermal-engineering teaching where learners measure heat, temperature, pressure, work, efficiency or energy balance.

What to include in the RFQ

State the product name, quantity, destination, curriculum or tender reference, and heat source, measurement points, operating range, instrumentation, utilities, safety provisions and experiment list. This lets the technical team respond against the intended use rather than guess from a model code.

How distributors should quote it

Keep Nozzle Performance Study System as the BOQ line item. Add the proposed model, included accessories, documentation, packing and delivery basis as separate fields so the end buyer can verify the offer.

How to compare suppliers

Ask every bidder to state the measurable parameters, operating conditions and included instruments against the same syllabus outcome. Record exclusions and alternatives in writing before commercial comparison.

Why Buy From Scientico

🏭

In-House Manufacturer

Designed & built in our Ambala facility since 1993 — not a reseller. Full control over quality & customisation.

✅

Configuration Review

Specifications, documentation and options are confirmed against the selected model.

🌏

International Enquiries

Share your destination and procurement requirements for an export quotation.

📦

Quote-Based Supply

Send the model, quantity and delivery location for a tailored proposal.

🛠

Support Scope

Support and warranty terms are documented in the applicable quotation.

🎓

Built for Teaching

Designed around curriculum experiments with clear, repeatable, hands-on results.

Frequently Asked Questions

Q1: How many nozzles are included with the Nozzle Performance Study System ThermoFlux - 7094? Five brass nozzles are included: four convergent-divergent nozzles with a 2 mm throat diameter and one convergent nozzle with a diameter of 2.19 mm. All nozzles range in length from 3.6 mm to 15.8 mm and can be exchanged rapidly.

Q2: How is force measured in this nozzle performance study system? Both reaction force (thrust) at the nozzle and action force at the baffle plate are measured by deformation of a flexion pipe. The measuring range is 0 to 5 N.

Q3: How is back pressure adjusted during experiments? Back pressure is adjusted using a needle valve on the flowmeter. A compressed air regulator with a control range of 0 to 10 bar also adjusts the pressure downstream of the nozzle.

Q4: What parameters does the unit measure? The unit measures temperature (-100 to 400°C), pressure at two points (0 to 10 bar each), mass flow (0.7 to 8.3 g/s), and force (0 to 5 N) using a manometer, digital temperature display, flowmeter, and flexion pipe force measurement system.

Q5: Is a compressor included with the unit? No. Compressed air is supplied from a separate compressor. An optional air compressor suitable for continuous operation (ThermoFlux - 7094) is available as an accessory.

Related Guides & Resources

In-depth guides from Scientico on Thermodynamics lab setup, experiments and procurement.

Nozzle Performance Study System | ThermoFlux - 7094

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Marcet Boiler | ThermoFlux – 7047, model-specific lab equipment manufactured by Scientico IndiaMarcet Boiler | ThermoFlux – 7047Nozzle Pressure Distribution ThermoFlux – 7103, Scientico IndiaNozzle Pressure Distribution | ThermoFlux – 7103Linear Heat Conduction Module | ThermoFlux – 7049/1, Scientico IndiaLinear Heat Conduction Module | ThermoFlux – 7049/1Perfect Gas Law Apparatus ThermoFlux – 7077, Scientico IndiaPerfect Gas Law Apparatus | ThermoFlux – 7077Linear and Radial Heat Transfer Unit | ThermoFlux – 7043, model-specific lab equipment manufactured by Scientico IndiaLinear and Radial Heat Transfer Unit | ThermoFlux – 7043Plate Type Heat Exchanger | ThermoFlux – 7108/1, Scientico IndiaPlate Type Heat Exchanger | ThermoFlux – 7108/1Joule-Thomson Apparatus | ThermoFlux-28, Scientico IndiaJoule-Thomson Apparatus | ThermoFlux-28Pressure Measurement Bench by Scientico IndiaPressure Measurement Bench | ThermoFlux – 7015
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.

Nozzle Performance Study System | ThermoFlux - 7094