🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
✓ Established 1993 ✓ Model-Specific Specifications ✓ Manufacturer-Direct Enquiries ✓ International Quotations ✓ Destination-Based Delivery Terms

Simple Compression Refrigeration

Model PolarX - 501

The Simple Compression Refrigeration PolarX-501 is a benchtop refrigeration training unit for engineering laboratories demonstrating the full compression refrigeration and heat pump cycle using R134a CFC-free refrigerant. This simple compression refrigeration apparatus includes a piston compressor (104 W, 278 W refrigeration capacity at 5/40°C), thermostatic expansion valve, pipe coil evaporator, and pipe coil condenser, each submerged in 1700 ml water tanks for direct energy balance measurement. Six Type-K temperature sensors (-40 to 400°C), two pressure gauges (-1 to 16 bar suction, -1 to 25 bar delivery), a sight glass, pressure safety switch, 1.2 L liquid receiver, filter drier, and a digital multifunctional power meter (0 to 500 V, 0 to 40 A) provide complete instrumentation. Optional LabVIEW-based Software PX-501 enables digital data acquisition and results calculation on any Windows operating system.

The Simple Compression Refrigeration PolarX – 501 is a bench-top laboratory unit designed to demonstrate the fundamentals of a compression refrigeration cycle using a piston compressor, thermostatic expansion valve, pipe coil evaporator, and pipe coil condenser. This simple compression refrigeration unit uses CFC-free refrigerant R134a, includes two water-filled tanks with temperature sensors to simulate the environment, and is fully instrumented with pressure gauges, six K-type temperature sensors, a sight glass, and a digital multifunctional power meter for comprehensive refrigeration cycle analysis.


Product Overview

The Simple Compression Refrigeration PolarX – 501 demonstrates a straightforward compression refrigeration system in a simplified bench-top format. The four primary components of the refrigeration circuit are a piston compressor, a thermostatic expansion valve, an evaporator, and a condenser. Both the evaporator and condenser are formed as pipe coils, with each end submerged in a separate water-filled tank to simulate the environment. The cold water tank represents heat removal (evaporator side) and the hot water tank represents heat rejection (condenser side).

The compressor has a power consumption of 104 W at 5/40°C and a refrigeration capacity of 278 W at 5/40°C. Refrigerant R134a (CFC-free) is used throughout the circuit. Two manometers display the refrigerant pressures on the high-pressure side (-1 to 25 bar) and the low-pressure side (-1 to 16 bar). The evaporation temperature of the refrigerant is displayed on a separate scale on the low-pressure manometer. A sight glass upstream of the expansion valve shows the aggregate state of the refrigerant.

Six K-type temperature sensors with a range of -40 to 400°C measure temperatures digitally across the system. Two water-filled tanks of 1700 ml each are fitted with temperature sensors for monitoring the cooling and heating effects. A pressure switch protects the compressor on both the suction side and the delivery side. A liquid receiver with a maximum working pressure of 450 psig and a capacity of 1.2 L is included. A filter drier rated at a maximum working pressure of 450 psig is also fitted. A digital multifunctional power meter measures AC voltage (0 to 500 V) and AC current (0 to 40 A). Optional LabVIEW-based DAQ software is available for PC-based data acquisition.

Technical Specifications

Parameter Detail
Model Reference PolarX-501
Category Refrigeration and Air Conditioning
Refrigerant R134a, CFC-free
Compressor Type Piston compressor
Compressor Power Consumption 104 W at 5/40°C
Refrigeration Capacity 278 W at 5/40°C
Suction Side Pressure Range -1 to 16 bar
Delivery Side Pressure Range -1 to 25 bar
Expansion Element Thermostatic expansion valve
Evaporator Pipe coil submerged in water tank
Condenser Pipe coil submerged in water tank
Water Tank Volume 2 x 1700 ml
Temperature Sensors 6 x Type-K, range -40 to 400°C
Sight Glass Upstream of expansion valve
Pressure Safety Switch Suction side and delivery side
Liquid Receiver Capacity 1.2 L
Liquid Receiver Max Working Pressure 450 psig
Filter Drier Max Working Pressure 450 psig
AC Volt Measurement Range 0 to 500 V
AC Ampere Measurement Range 0 to 40 A
Optional Software Software PX-501 (LabVIEW-based, Windows compatible)

Technical Data

Compressor

Parameter Value
Power Consumption 104 W at 5/40°C
Refrigeration Capacity 278 W at 5/40°C

Pressure Gauges

Parameter Value
Suction Side (Low Pressure) -1 to 16 bar
Delivery Side (High Pressure) -1 to 25 bar

Temperature Sensors

Parameter Value
Type Type-K
Range -40 to 400°C
Quantity 6

Water Tanks

Parameter Value
Quantity 2
Volume each 1700 ml

Liquid Receiver

Parameter Value
Maximum Working Pressure 450 psig
Capacity 1.2 L

Filter Drier

Parameter Value
Maximum Working Pressure 450 psig

Digital Multifunctional Power Meter

Parameter Value
AC Voltage Range 0 to 500 V
AC Current Range 0 to 40 A

Key Features

  • Refrigerant Circuit: R134a CFC-free refrigerant through piston compressor, thermostatic expansion valve, pipe coil evaporator, and pipe coil condenser
  • Compressor Performance: 104 W power consumption, 278 W refrigeration capacity at 5/40°C on this simple compression refrigeration apparatus
  • Pressure Monitoring: two manometers, suction side -1 to 16 bar, delivery side -1 to 25 bar, with separate evaporation temperature scale
  • Temperature Measurement: 6 x Type-K sensors, -40 to 400°C range, digital display
  • Water Tanks: 2 x 1700 ml tanks simulate environment for evaporator (cold side) and condenser (hot side) heat exchange measurement
  • Sight Glass: monitors aggregate state of refrigerant upstream of expansion valve
  • Pressure Safety Switch: protects compressor on both suction and delivery sides
  • Liquid Receiver: 1.2 L capacity, 450 psig maximum working pressure
  • Filter Drier: 450 psig maximum working pressure
  • Power Meter: digital multifunctional, 0 to 500 V AC and 0 to 40 A AC measurement
  • Optional Software: PX-501, LabVIEW-based DAQ software for measurement and results calculation on any Windows operating system

Experiments

  • Compression refrigeration circuit fundamentals
  • Identification of the compressor, evaporator, condenser, and expansion element as primary refrigeration system components
  • The connection between a liquid’s boiling point and pressure
  • The use of a heat pump or refrigeration system
  • Gaining a fundamental knowledge of the thermodynamic cycle
  • Simple energy balance

Construction and Design

The Simple Compression Refrigeration PolarX-501 is a self-contained benchtop unit housing all primary refrigeration cycle components. The piston compressor drives refrigerant R134a through a closed circuit. The condenser and evaporator are each constructed as pipe coils, with both ends of each coil submerged in separate 1700 ml water-filled tanks that simulate the hot-side and cold-side environments. A thermostatic expansion valve controls refrigerant flow between the high-pressure and low-pressure sides of the circuit. Two manometers display suction side pressure (-1 to 16 bar) and delivery side pressure (-1 to 25 bar). Six Type-K temperature sensors across the circuit provide digital temperature readouts over a -40 to 400°C range, with a separate scale for evaporation temperature. A sight glass positioned upstream of the expansion valve allows direct visual monitoring of the refrigerant’s aggregate state. A pressure safety switch on both suction and delivery sides protects the compressor from overpressure conditions. A 1.2 L liquid receiver and a filter drier, both rated to 450 psig maximum working pressure, are integrated into the high-pressure side. A digital multifunctional power meter measures AC voltage and current for power consumption analysis. Optional Software PX-501 developed in National Instruments LabVIEW provides DAQ-based measurement, data logging, and results calculation compatible with any Windows operating system, with electronic sensors included when the software option is selected.

Software

Software PX-501 (Optional): DAQ software developed in National Instruments LabVIEW environment for measuring and calculating experimental results. Electronic sensors are included with the software option. Compatible with any Windows operating system.

Scope of Delivery

  • 1 experimental module
  • 1 instruction manual

Q1: What refrigerant does the Simple Compression Refrigeration PolarX-501 use?
The unit uses R134a, a CFC-free refrigerant widely used in commercial and industrial refrigeration and heat pump systems.

Q2: How are the cooling and heating effects measured on this simple compression refrigeration apparatus?
The evaporator and condenser pipe coils are each submerged in separate 1700 ml water-filled tanks. Temperature sensors in each tank measure the temperature change caused by heat absorption (evaporator, cold water) and heat rejection (condenser, hot water), enabling direct energy balance calculations.

Q3: What pressure ranges are covered by the two manometers?
The suction side (low pressure) manometer covers -1 to 16 bar. The delivery side (high pressure) manometer covers -1 to 25 bar.

Q4: What is the function of the sight glass on the PolarX-501?
The sight glass is positioned upstream of the expansion valve and allows direct visual monitoring of the aggregate state of the refrigerant, indicating whether the refrigerant is in liquid or vapour phase at that point in the circuit.

Q5: Is data acquisition software available for the PolarX-501?
Yes. Optional Software PX-501, developed in National Instruments LabVIEW, provides digital data acquisition, measurement, and results calculation. Electronic sensors are included when this option is selected, and the software runs on any Windows operating system.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Simple Compression Refrigeration | PolarX – 501 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send the model, quantity, destination and required Incoterm. We will confirm the supplied scope and available export documents.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender that requests a manufacturer authorisation form (MAF)? Send the tender reference, deadline and listed equipment so we can confirm what can be issued.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Refrigeration and Air ConditioningModel PolarX - 501
🏭
Manufacturer DirectProduct-specific enquiry, not a generic catalogue
🌍
Destination MatchedConfiguration and delivery scope reviewed together
📄
Decision-Ready ReplyApplicable documentation confirmed before ordering
Product-specific enquiry

Get a quotation your team can evaluate

A bare price can hide configuration, accessories, voltage, documentation and delivery assumptions. Send the product and destination now so the quoted scope can be reviewed before a purchase decision.

Avoid the mismatchDo not approve a generic price that leaves supplied scope unclear.
Your product is attachedNo need to retype the model or copy the page URL.
Move toward an approvable quoteAdd the destination; quantity and tender details can follow.

No account is required. Organisation, quantity and tender details are optional. Include the country code so the team can reach you internationally.

1993
Manufacturing Since
Direct
Manufacturer Supply
Quote-based
International Orders
Model
PolarX - 501

Overview

The Simple Compression Refrigeration PolarX - 501 is a bench-top laboratory unit designed to demonstrate the fundamentals of a compression refrigeration cycle using a piston compressor, thermostatic expansion valve, pipe coil evaporator, and pipe coil condenser. This simple compression refrigeration unit uses CFC-free refrigerant R134a, includes two water-filled tanks with temperature sensors to simulate the environment, and is fully instrumented with pressure gauges, six K-type temperature sensors, a sight glass, and a digital multifunctional power meter for comprehensive refrigeration cycle analysis.


Product Overview

The Simple Compression Refrigeration PolarX - 501 demonstrates a straightforward compression refrigeration system in a simplified bench-top format. The four primary components of the refrigeration circuit are a piston compressor, a thermostatic expansion valve, an evaporator, and a condenser. Both the evaporator and condenser are formed as pipe coils, with each end submerged in a separate water-filled tank to simulate the environment. The cold water tank represents heat removal (evaporator side) and the hot water tank represents heat rejection (condenser side).

The compressor has a power consumption of 104 W at 5/40°C and a refrigeration capacity of 278 W at 5/40°C. Refrigerant R134a (CFC-free) is used throughout the circuit. Two manometers display the refrigerant pressures on the high-pressure side (-1 to 25 bar) and the low-pressure side (-1 to 16 bar). The evaporation temperature of the refrigerant is displayed on a separate scale on the low-pressure manometer. A sight glass upstream of the expansion valve shows the aggregate state of the refrigerant.

Six K-type temperature sensors with a range of -40 to 400°C measure temperatures digitally across the system. Two water-filled tanks of 1700 ml each are fitted with temperature sensors for monitoring the cooling and heating effects. A pressure switch protects the compressor on both the suction side and the delivery side. A liquid receiver with a maximum working pressure of 450 psig and a capacity of 1.2 L is included. A filter drier rated at a maximum working pressure of 450 psig is also fitted. A digital multifunctional power meter measures AC voltage (0 to 500 V) and AC current (0 to 40 A). Optional LabVIEW-based DAQ software is available for PC-based data acquisition.

Key Features

Key Features

  • Refrigerant Circuit: R134a CFC-free refrigerant through piston compressor, thermostatic expansion valve, pipe coil evaporator, and pipe coil condenser
  • Compressor Performance: 104 W power consumption, 278 W refrigeration capacity at 5/40°C on this simple compression refrigeration apparatus
  • Pressure Monitoring: two manometers, suction side -1 to 16 bar, delivery side -1 to 25 bar, with separate evaporation temperature scale
  • Temperature Measurement: 6 x Type-K sensors, -40 to 400°C range, digital display
  • Water Tanks: 2 x 1700 ml tanks simulate environment for evaporator (cold side) and condenser (hot side) heat exchange measurement
  • Sight Glass: monitors aggregate state of refrigerant upstream of expansion valve
  • Pressure Safety Switch: protects compressor on both suction and delivery sides
  • Liquid Receiver: 1.2 L capacity, 450 psig maximum working pressure
  • Filter Drier: 450 psig maximum working pressure
  • Power Meter: digital multifunctional, 0 to 500 V AC and 0 to 40 A AC measurement
  • Optional Software: PX-501, LabVIEW-based DAQ software for measurement and results calculation on any Windows operating system

Experiments

  • Compression refrigeration circuit fundamentals
  • Identification of the compressor, evaporator, condenser, and expansion element as primary refrigeration system components
  • The connection between a liquid's boiling point and pressure
  • The use of a heat pump or refrigeration system
  • Gaining a fundamental knowledge of the thermodynamic cycle
  • Simple energy balance

Construction and Design

The Simple Compression Refrigeration PolarX-501 is a self-contained benchtop unit housing all primary refrigeration cycle components. The piston compressor drives refrigerant R134a through a closed circuit. The condenser and evaporator are each constructed as pipe coils, with both ends of each coil submerged in separate 1700 ml water-filled tanks that simulate the hot-side and cold-side environments. A thermostatic expansion valve controls refrigerant flow between the high-pressure and low-pressure sides of the circuit. Two manometers display suction side pressure (-1 to 16 bar) and delivery side pressure (-1 to 25 bar). Six Type-K temperature sensors across the circuit provide digital temperature readouts over a -40 to 400°C range, with a separate scale for evaporation temperature. A sight glass positioned upstream of the expansion valve allows direct visual monitoring of the refrigerant's aggregate state. A pressure safety switch on both suction and delivery sides protects the compressor from overpressure conditions. A 1.2 L liquid receiver and a filter drier, both rated to 450 psig maximum working pressure, are integrated into the high-pressure side. A digital multifunctional power meter measures AC voltage and current for power consumption analysis. Optional Software PX-501 developed in National Instruments LabVIEW provides DAQ-based measurement, data logging, and results calculation compatible with any Windows operating system, with electronic sensors included when the software option is selected.

Software

Software PX-501 (Optional): DAQ software developed in National Instruments LabVIEW environment for measuring and calculating experimental results. Electronic sensors are included with the software option. Compatible with any Windows operating system.

Scope of Delivery

  • 1 experimental module
  • 1 instruction manual

Specifications

Technical Specifications

Parameter Detail
Model Reference PolarX-501
Category Refrigeration and Air Conditioning
Refrigerant R134a, CFC-free
Compressor Type Piston compressor
Compressor Power Consumption 104 W at 5/40°C
Refrigeration Capacity 278 W at 5/40°C
Suction Side Pressure Range -1 to 16 bar
Delivery Side Pressure Range -1 to 25 bar
Expansion Element Thermostatic expansion valve
Evaporator Pipe coil submerged in water tank
Condenser Pipe coil submerged in water tank
Water Tank Volume 2 x 1700 ml
Temperature Sensors 6 x Type-K, range -40 to 400°C
Sight Glass Upstream of expansion valve
Pressure Safety Switch Suction side and delivery side
Liquid Receiver Capacity 1.2 L
Liquid Receiver Max Working Pressure 450 psig
Filter Drier Max Working Pressure 450 psig
AC Volt Measurement Range 0 to 500 V
AC Ampere Measurement Range 0 to 40 A
Optional Software Software PX-501 (LabVIEW-based, Windows compatible)

Technical Data

Compressor

Parameter Value
Power Consumption 104 W at 5/40°C
Refrigeration Capacity 278 W at 5/40°C

Pressure Gauges

Parameter Value
Suction Side (Low Pressure) -1 to 16 bar
Delivery Side (High Pressure) -1 to 25 bar

Temperature Sensors

Parameter Value
Type Type-K
Range -40 to 400°C
Quantity 6

Water Tanks

Parameter Value
Quantity 2
Volume each 1700 ml

Liquid Receiver

Parameter Value
Maximum Working Pressure 450 psig
Capacity 1.2 L

Filter Drier

Parameter Value
Maximum Working Pressure 450 psig

Digital Multifunctional Power Meter

Parameter Value
AC Voltage Range 0 to 500 V
AC Current Range 0 to 40 A

Buying Simple Compression Refrigeration: Distributor & Tender Guidance

Simple Compression Refrigeration is the product name procurement teams should use when searching, preparing a BOQ or comparing suppliers. A model reference identifies the proposed configuration; it should not replace the product name or the buyer’s required experiment. This equipment is considered for refrigeration and air-conditioning teaching involving cycles, components, psychrometrics, cooling performance or coefficient-of-performance calculations.

What to include in the RFQ

State the product name, quantity, destination, curriculum or tender reference, and cycle or system type, refrigerant, compressor and heat exchangers, measurement points, controls, utilities and experiments. This lets the technical team respond against the intended use rather than guess from a model code.

How distributors should quote it

Keep Simple Compression Refrigeration as the BOQ line item. Add the proposed model, included accessories, documentation, packing and delivery basis as separate fields so the end buyer can verify the offer.

How to compare suppliers

Compare the actual cycle, instrumented state points and calculations supported by the offered system. Record exclusions and alternatives in writing before commercial comparison.

Plan a compression-cycle teaching workstation

The Simple Compression Refrigeration | PolarX – 501 is a benchtop choice for a laboratory purchasing equipment to demonstrate the compression refrigeration and heat-pump cycle. The current product record describes a compressor, expansion valve, evaporator and condenser, with water tanks used for energy-balance measurements. That gives a department a specific purchasing task: decide whether observing the circuit and measuring its behaviour meets the practical outcomes before requesting a broader refrigeration package.

Define the measurements students need

For an engineering college, list the readings that students must collect and the calculations they must complete. Ask the quotation to identify the supplied temperature, pressure and electrical measurement arrangement and the matching experiment instructions. If results must be recorded digitally, request a separate statement of the software, interface hardware, computer requirements and licences included in the offer. Optional data acquisition should not be assumed to form part of the base order.

A distributor preparing a college equipment schedule should retain the exact product and model reference, unit count and customer’s practical requirements. An HVAC duct trainer or electrical-fault simulator addresses a different task; neither is automatically interchangeable with this cycle-demonstration unit.

Complete the purchase schedule

  • State the model, quantity, student group arrangement and intended cycle measurements.
  • Request confirmation of the working-fluid specification, electrical supply and space needed for the offered unit.
  • Identify supplied manuals, accessories, optional recording functions and any installation or training scope.
  • Include delivery country and city, tender reference and submission date when applicable.

Compare the final supplied scope and terms in the written quotation, especially where several suppliers use a similar apparatus name.

Browse refrigeration and air-conditioning equipment · Compare refrigeration trainer families · Request a quotation for Simple Compression Refrigeration | PolarX – 501

Why Buy From Scientico

🏭

In-House Manufacturer

Designed & built in our Ambala facility since 1993 — not a reseller. Full control over quality & customisation.

✅

Configuration Review

Specifications, documentation and options are confirmed against the selected model.

🌏

International Enquiries

Share your destination and procurement requirements for an export quotation.

📦

Quote-Based Supply

Send the model, quantity and delivery location for a tailored proposal.

🛠

Support Scope

Support and warranty terms are documented in the applicable quotation.

🎓

Built for Teaching

Designed around curriculum experiments with clear, repeatable, hands-on results.

Frequently Asked Questions

Q1: What refrigerant does the Simple Compression Refrigeration PolarX-501 use? The unit uses R134a, a CFC-free refrigerant widely used in commercial and industrial refrigeration and heat pump systems.

Q2: How are the cooling and heating effects measured on this simple compression refrigeration apparatus? The evaporator and condenser pipe coils are each submerged in separate 1700 ml water-filled tanks. Temperature sensors in each tank measure the temperature change caused by heat absorption (evaporator, cold water) and heat rejection (condenser, hot water), enabling direct energy balance calculations.

Q3: What pressure ranges are covered by the two manometers? The suction side (low pressure) manometer covers -1 to 16 bar. The delivery side (high pressure) manometer covers -1 to 25 bar.

Q4: What is the function of the sight glass on the PolarX-501? The sight glass is positioned upstream of the expansion valve and allows direct visual monitoring of the aggregate state of the refrigerant, indicating whether the refrigerant is in liquid or vapour phase at that point in the circuit.

Q5: Is data acquisition software available for the PolarX-501? Yes. Optional Software PX-501, developed in National Instruments LabVIEW, provides digital data acquisition, measurement, and results calculation. Electronic sensors are included when this option is selected, and the software runs on any Windows operating system.

Related Guides & Resources

In-depth guides from Scientico on Refrigeration and Air Conditioning lab setup, experiments and procurement.

Simple Compression Refrigeration | PolarX - 501

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Reverse Cycle Refrigeration & AC Training Unit by Scientico IndiaReverse Cycle Refrigeration & AC Training Unit | PolarX – 536Split AC System Trainer by Scientico IndiaSplit AC System Trainer | PolarX – 552Refrigerator Model by Scientico IndiaRefrigerator Model | PolarX – 588Universal Pumping Unit by Scientico IndiaUniversal Pumping Unit | PolarX – 528Refrigeration System with Two-Stage Compression by Scientico IndiaRefrigeration System with Two-Stage Compression | PolarX – 532Vortex Tube Refrigerator | PolarX – 508, Scientico IndiaVortex Tube Refrigerator | PolarX – 508Refrigeration System with Open Compressor | PolarX – 520, Scientico IndiaRefrigeration System with Open Compressor | PolarX – 520Absorption Refrigeration Trainer | PolarX – 504, Scientico IndiaAbsorption Refrigeration Trainer | PolarX – 504
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.

Simple Compression Refrigeration | PolarX - 501