🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
✓ Established 1993 ✓ Model-Specific Specifications ✓ Manufacturer-Direct Enquiries ✓ International Quotations ✓ Destination-Based Delivery Terms

Study of I/P and P/I Converter

Model Prozessi PX 13

The Study of I/P and P/I Converter, Prozessi PX 13, is a tabletop trainer for electronic and pneumatic signal conversion studies. It includes an I/P converter, P/I converter, digital calibrator, pressure gauges, air regulator, and air filter regulator. The setup supports the Study of I/P and P/I Converter for working, calibration, linearity, hysteresis, accuracy, and repeatability. All components are mounted on a compact support housing for tabletop use.

The Study of I/P and P/I Converter, Prozessi PX 13, is a tabletop trainer built for understanding electronic to pneumatic and pneumatic to electronic signal conversion. This setup on Study of I/P and P/I Converter allows students to study the working, calibration, and performance characteristics of both converter types in a single compact unit.

Product Overview

The Study of I/P and P/I Converter, Prozessi PX 13, consists of an I/P converter, a P/I converter, a digital calibrator, pressure gauges, an air regulator, and an air filter regulator. The digital calibrator acts as a current source, supplying 4 to 20 mA DC to the I/P converter, and as a current sink, receiving the output current in mA DC from the P/I converter. The I/P converter produces an output of 3 to 15 psig, and the P/I converter produces an output of 4 to 20 mA DC. All components, along with the required piping and fittings, are mounted on a support housing designed for tabletop use. The unit enables study of I/P and P/I converter working, calibration, and characteristics including linearity, hysteresis, accuracy, and repeatability.

Study of I/P and P/I Converter, Prozessi PX 13 – Technical Specifications

Parameter Specification
Product Study of I/P and P/I converter
Product code Prozessi PX 13
Pressure Transmitter Two wire type, range 0 to 1 bar, output 4 to 20 mA
I/P Converter Input 4 to 20 mA, output 3 to 15 psig
Signal Isolator Input 4 to 20 mA, output 4 to 20 mA
Digital Calibrator Sink/Source, mA/mV mode
Air Regulator Range 0 to 2.5 kg/cm2
Air Filter Regulator Range 0 to 2.5 kg/cm2
Pressure Gauge Range 0 to 2.5 kg/cm2 (2 Nos), Range 0 to 7 kg/cm2 (1 No)
Overall Dimensions 550W x 300D x 400H mm
Optional Mini compressor

Technical Data

Pressure Transmitter

Parameter Value
Type Two wire
Range 0 to 1 bar
Output 4 to 20 mA

I/P Converter

Parameter Value
Input 4 to 20 mA
Output 3 to 15 psig

Signal Isolator

Parameter Value
Input 4 to 20 mA
Output 4 to 20 mA

Digital Calibrator

Parameter Value
Mode Sink/Source, mA/mV

Air Regulator

Parameter Value
Range 0 to 2.5 kg/cm2

Air Filter Regulator

Parameter Value
Range 0 to 2.5 kg/cm2

Pressure Gauge

Parameter Value
Range 1 0 to 2.5 kg/cm2, 2 Nos
Range 2 0 to 7 kg/cm2, 1 No

Key Features

  • Mounting: Table mounted setup
  • Operation: Compact and simple to operate
  • Calibration: Digital calibrator, sink/source, mA/mV mode
  • Configuration: Combined setup for Study of I/P and P/I Converter
  • Signal Path: I/P converter input 4 to 20 mA, output 3 to 15 psig

Experiments

  • Study of flapper nozzle system
  • Study of working principle and calibration procedure of I/P converter
  • Study of working principle and calibration procedure of P/I converter
  • Study of linearity, hysteresis, accuracy and repeatability of I/P converter
  • Study of linearity, hysteresis, accuracy and repeatability of P/I converter

Construction and Design

The Study of I/P and P/I Converter, Prozessi PX 13, is built around a support housing designed for tabletop mounting. The I/P converter, P/I converter, digital calibrator, pressure gauges, air regulator, and air filter regulator are all mounted on this housing. All components are connected through the required piping and fittings. The compact layout supports the Study of I/P and P/I Converter for both converter types in one unit.

Scope of Delivery

  • I/P converter
  • P/I converter
  • Digital calibrator
  • Pressure gauges (2 Nos range 0 to 2.5 kg/cm2, 1 No range 0 to 7 kg/cm2)
  • Air regulator
  • Air filter regulator
  • Support housing with piping and fittings

Optional Accessories

  • Mini compressor

Required for Operation

  • Electric supply: 230 +/- 10 VAC, 50 Hz, 1 phase
  • Air supply: Clean, oil and moisture free air, pressure 2 bar, consumption 50 LPH

Q1: What is the purpose of the Study of I/P and P/I Converter setup?
A: It is designed for understanding the basic principles of electronic and pneumatic signal conversion, using an I/P converter and a P/I converter.

Q2: What output does the I/P converter give in this setup?
A: The I/P converter gives an output of 3 to 15 psig for an input of 4 to 20 mA.

Q3: What output does the P/I converter give?
A: The P/I converter gives an output of 4 to 20 mA DC.

Q4: What role does the digital calibrator play?
A: It acts as a current source, supplying 4 to 20 mA DC to the I/P converter, and as a current sink, receiving the output current from the P/I converter.

Q5: What parameters can be studied using this setup?
A: Linearity, hysteresis, accuracy, and repeatability of both the I/P and P/I converters, along with the flapper nozzle system.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Study of I/P and P/I Converter | Prozessi PX 13 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send the model, quantity, destination and required Incoterm. We will confirm the supplied scope and available export documents.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender that requests a manufacturer authorisation form (MAF)? Send the tender reference, deadline and listed equipment so we can confirm what can be issued.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Process Engineering TechnologyModel Prozessi PX 13
🏭
Manufacturer DirectProduct-specific enquiry, not a generic catalogue
🌍
Destination MatchedConfiguration and delivery scope reviewed together
📄
Decision-Ready ReplyApplicable documentation confirmed before ordering
Product-specific enquiry

Get a quotation your team can evaluate

A bare price can hide configuration, accessories, voltage, documentation and delivery assumptions. Send the product and destination now so the quoted scope can be reviewed before a purchase decision.

Avoid the mismatchDo not approve a generic price that leaves supplied scope unclear.
Your product is attachedNo need to retype the model or copy the page URL.
Move toward an approvable quoteAdd the destination; quantity and tender details can follow.

No account is required. Organisation, quantity and tender details are optional. Include the country code so the team can reach you internationally.

1993
Manufacturing Since
Direct
Manufacturer Supply
Quote-based
International Orders
Model
Prozessi PX 13

Overview

The Study of I/P and P/I Converter, Prozessi PX 13, is a tabletop trainer built for understanding electronic to pneumatic and pneumatic to electronic signal conversion. This setup on Study of I/P and P/I Converter allows students to study the working, calibration, and performance characteristics of both converter types in a single compact unit.

Product Overview

The Study of I/P and P/I Converter, Prozessi PX 13, consists of an I/P converter, a P/I converter, a digital calibrator, pressure gauges, an air regulator, and an air filter regulator. The digital calibrator acts as a current source, supplying 4 to 20 mA DC to the I/P converter, and as a current sink, receiving the output current in mA DC from the P/I converter. The I/P converter produces an output of 3 to 15 psig, and the P/I converter produces an output of 4 to 20 mA DC. All components, along with the required piping and fittings, are mounted on a support housing designed for tabletop use. The unit enables study of I/P and P/I converter working, calibration, and characteristics including linearity, hysteresis, accuracy, and repeatability.

Key Features

Key Features

  • Mounting: Table mounted setup
  • Operation: Compact and simple to operate
  • Calibration: Digital calibrator, sink/source, mA/mV mode
  • Configuration: Combined setup for Study of I/P and P/I Converter
  • Signal Path: I/P converter input 4 to 20 mA, output 3 to 15 psig

Experiments

  • Study of flapper nozzle system
  • Study of working principle and calibration procedure of I/P converter
  • Study of working principle and calibration procedure of P/I converter
  • Study of linearity, hysteresis, accuracy and repeatability of I/P converter
  • Study of linearity, hysteresis, accuracy and repeatability of P/I converter

Construction and Design

The Study of I/P and P/I Converter, Prozessi PX 13, is built around a support housing designed for tabletop mounting. The I/P converter, P/I converter, digital calibrator, pressure gauges, air regulator, and air filter regulator are all mounted on this housing. All components are connected through the required piping and fittings. The compact layout supports the Study of I/P and P/I Converter for both converter types in one unit.

Scope of Delivery

  • I/P converter
  • P/I converter
  • Digital calibrator
  • Pressure gauges (2 Nos range 0 to 2.5 kg/cm2, 1 No range 0 to 7 kg/cm2)
  • Air regulator
  • Air filter regulator
  • Support housing with piping and fittings

Optional Accessories

  • Mini compressor

Required for Operation

  • Electric supply: 230 +/- 10 VAC, 50 Hz, 1 phase
  • Air supply: Clean, oil and moisture free air, pressure 2 bar, consumption 50 LPH

Specifications

Study of I/P and P/I Converter, Prozessi PX 13 - Technical Specifications

Parameter Specification
Product Study of I/P and P/I converter
Product code Prozessi PX 13
Pressure Transmitter Two wire type, range 0 to 1 bar, output 4 to 20 mA
I/P Converter Input 4 to 20 mA, output 3 to 15 psig
Signal Isolator Input 4 to 20 mA, output 4 to 20 mA
Digital Calibrator Sink/Source, mA/mV mode
Air Regulator Range 0 to 2.5 kg/cm2
Air Filter Regulator Range 0 to 2.5 kg/cm2
Pressure Gauge Range 0 to 2.5 kg/cm2 (2 Nos), Range 0 to 7 kg/cm2 (1 No)
Overall Dimensions 550W x 300D x 400H mm
Optional Mini compressor

Technical Data

Pressure Transmitter

Parameter Value
Type Two wire
Range 0 to 1 bar
Output 4 to 20 mA

I/P Converter

Parameter Value
Input 4 to 20 mA
Output 3 to 15 psig

Signal Isolator

Parameter Value
Input 4 to 20 mA
Output 4 to 20 mA

Digital Calibrator

Parameter Value
Mode Sink/Source, mA/mV

Air Regulator

Parameter Value
Range 0 to 2.5 kg/cm2

Air Filter Regulator

Parameter Value
Range 0 to 2.5 kg/cm2

Pressure Gauge

Parameter Value
Range 1 0 to 2.5 kg/cm2, 2 Nos
Range 2 0 to 7 kg/cm2, 1 No

Buying Study of I/P and P/I Converter: Distributor & Tender Guidance

Study of I/P and P/I Converter is the product name procurement teams should use when searching, preparing a BOQ or comparing suppliers. A model reference identifies the proposed configuration; it should not replace the product name or the buyer’s required experiment. This equipment is considered for process-engineering practicals involving flow, level, pressure, temperature, reaction or industrial measurement and control.

What to include in the RFQ

State the product name, quantity, destination, curriculum or tender reference, and process variable, vessel or pipeline arrangement, sensors, controller, operating range, utilities, wetted materials and experiments. This lets the technical team respond against the intended use rather than guess from a model code.

How distributors should quote it

Keep Study of I/P and P/I Converter as the BOQ line item. Add the proposed model, included accessories, documentation, packing and delivery basis as separate fields so the end buyer can verify the offer.

How to compare suppliers

Compare the physical process, control loop, instrumentation and supplied software as separate tender line items. Record exclusions and alternatives in writing before commercial comparison.

Why Buy From Scientico

🏭

In-House Manufacturer

Designed & built in our Ambala facility since 1993 — not a reseller. Full control over quality & customisation.

✅

Configuration Review

Specifications, documentation and options are confirmed against the selected model.

🌏

International Enquiries

Share your destination and procurement requirements for an export quotation.

📦

Quote-Based Supply

Send the model, quantity and delivery location for a tailored proposal.

🛠

Support Scope

Support and warranty terms are documented in the applicable quotation.

🎓

Built for Teaching

Designed around curriculum experiments with clear, repeatable, hands-on results.

Frequently Asked Questions

Q1: What is the purpose of the Study of I/P and P/I Converter setup? A: It is designed for understanding the basic principles of electronic and pneumatic signal conversion, using an I/P converter and a P/I converter.

Q2: What output does the I/P converter give in this setup? A: The I/P converter gives an output of 3 to 15 psig for an input of 4 to 20 mA.

Q3: What output does the P/I converter give? A: The P/I converter gives an output of 4 to 20 mA DC.

Q4: What role does the digital calibrator play? A: It acts as a current source, supplying 4 to 20 mA DC to the I/P converter, and as a current sink, receiving the output current from the P/I converter.

Q5: What parameters can be studied using this setup? A: Linearity, hysteresis, accuracy, and repeatability of both the I/P and P/I converters, along with the flapper nozzle system.

Related Guides & Resources

In-depth guides from Scientico on Process Engineering Technology lab setup, experiments and procurement.

Study of I/P and P/I Converter | Prozessi PX 13

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Process Plant Trainer | ProzessiX PX-03, Scientico IndiaProcess Plant Trainer | ProzessiX PX-03Temperature Control Trainer by Scientico IndiaTemperature Control Trainer | Prozessi PX 14Pressure Control Trainer by Scientico IndiaPressure Control Trainer | Prozessi PX 17Temperature MeasurementTemperature Measurement Trainer | Prozessi PX 22Non-Linear-Level-ControlNon Linear Level Control | Prozessi PX 31Control valve characterization trainerTest Stand for Control Valves | Prozessi PX-32Multi-Variable-Control-TrainerMulti Variable Control Trainer | Prozessi PX 25True DCS TrainerTrue DCS Trainer | Prozessi PX 28
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.

Study of I/P and P/I Converter | Prozessi PX 13