🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
✓ Established 1993 ✓ Model-Specific Specifications ✓ Manufacturer-Direct Enquiries ✓ International Quotations ✓ Destination-Based Delivery Terms

Base unit for Refrigeration & Air Conditioning Training System

Model PolarX - 584

The Base unit for Refrigeration & Air Conditioning Training System PolarX – 584 extends into a full refrigeration circuit using various available models, including refrigerator, freezing-stage refrigeration, and air conditioning modules. This Base unit for Refrigeration & Air Conditioning Training System features a hermetically sealed compressor (470W capacity, 280W consumption), forced air condenser, and 0.7L liquid receiver, monitored by 3 temperature sensors and pressure sensors on intake (-1~15bar) and delivery (-1~25bar) sides. Advanced software connects via USB or LAN for real-time data acquisition, system operation, and educational analysis. Electronic high and low pressure switches provide safety protection.

The Base unit for Refrigeration & Air Conditioning Training System PolarX – 584 can be extended into a full refrigeration circuit depending on the experiment’s objectives. This Base unit for Refrigeration & Air Conditioning Training System supports various available models, including the refrigerator module, a refrigeration system with both cooling and freezing stages, or an air conditioning module.

Product Overview Key components of this training system include the compressor, condenser, receiver, and both electrical and communication systems. The models attach to the base unit and connect hydraulically through refrigerant hoses and electrically with cables. Self-sealing couplings minimize refrigerant loss, and the components are arranged to be clearly visible for monitoring their operation.

The system includes advanced software integrated with the hardware for ease of experimentation and analysis. The experimental unit connects to a PC via USB or LAN. The software includes a system operation and data acquisition program, as well as educational software that aids understanding with explanations and illustrations. Each model has a specific software module tailored to its learning objectives, and teachers can create additional exercises using an authoring system.

Sensors measure temperatures and pressures, which the software displays in real-time for both system operation and data acquisition. The software provides precise data on the refrigerant’s condition, allowing for accurate calculations of refrigerant mass flow rate. This method of calculation is more precise than traditional measurement techniques. The software also tracks the effects of parameter changes in a log p-h diagram and optionally allows system operation through the software.

Base unit for Refrigeration & Air Conditioning Training System PolarX – 584, Technical Specifications

Component Type / Detail
System Function Basic experiments on refrigeration and air conditioning systems via integration with various models
HSI Technology Available as an optional feature
Condensing Unit Compressor, condenser, receiver
Model Connection Refrigerant hoses between condensing unit and models
Model Attachment Firmly attached to the trainer using fasteners
Manometer Includes a temperature scale
Mass Flow Rate Calculation Accurately calculated through software (optional)
Refrigerant R134A (other refrigerants available on demand)
System Control Managed through solenoid valves and software (optional)
Software Functions Educational content, data acquisition, system operation (optional)

Technical Data

Compressor

Parameter Value
Type Hermetically sealed
Refrigeration Capacity 470W
Power Consumption 280W

Liquid Receiver

Parameter Value
Capacity 0.7L

Additional Components

Component Detail
Filter Dryer & Sight Glass Included
Bypass Valves Included

Refrigerant

Parameter Value
Type R134A (other refrigerants available on demand)

Condenser

Parameter Value
Type Forced air

Power Analyzer

Parameter Value
Function Shows power, voltage, and current consumed by compressor

Measuring Ranges – Temperature

Parameter Value
Sensors 3x -100~400°C

Measuring Ranges – Pressure

Parameter Value
Intake Side 1x -1~15bar
Delivery Side 2x -1~25bar

Safety

Component Detail
Electronic High Pressure Switch Included
Electronic Low Pressure Switch Included

Key Features

  • System Type: Base unit for Refrigeration & Air Conditioning Training System, extendable with multiple modules
  • Compressor: Hermetically sealed, 470W refrigeration capacity, 280W power consumption
  • Condenser: Forced air type
  • Liquid Receiver: 0.7L capacity
  • Connectivity: PC connection via USB or LAN, self-sealing refrigerant hose couplings
  • Software: System operation, data acquisition, and educational modules with authoring system
  • Temperature Sensors: 3x, range -100~400°C
  • Pressure Sensors: 1x intake side (-1~15bar), 2x delivery side (-1~25bar)
  • Safety Features: Electronic high pressure switch and electronic low pressure switch
  • Refrigerant: R134A, other refrigerants available on demand
  • Power Analyzer: Displays power, voltage, and current consumed by compressor

Experiments

  • Fundamentals of the refrigeration cycle (in conjunction with its different modules)
  • Fundamentals of air conditioning
  • Components in a refrigeration system/air conditioning system
  • System operation
  • Fault finding

Construction and Design
The Base unit for Refrigeration & Air Conditioning Training System PolarX – 584 integrates a condensing unit containing the compressor, condenser, and receiver as its core components. Models attach to the base unit using fasteners and connect hydraulically through refrigerant hoses with self-sealing couplings, and electrically via cables. All components are arranged for clear visibility during operation monitoring. A manometer with an integrated temperature scale supports refrigerant condition readings. Electronic high pressure and low pressure switches provide safety protection. The system connects to a PC via USB or LAN for real-time software-based monitoring and analysis.

Software
PolarX – 584 (optional). A DAQ software package, specially designed in National Instruments LABVIEW environment, measures and calculates the results of the apparatus. The software is optional. When the software is used, a set of electronic sensors is included. The software can be run on any Windows environment.

Recommended Accessories (optional)

  • Refrigerator Model, PolarX – 588
  • Model of a Refrigeration System with Refrigeration and Freezing Stage, PolarX – 592
  • Maintenance Kit, PolarX – 596

Scope of Delivery

  • 1 Base Unit
  • 1 instructional manual

Q: Can the Base unit for Refrigeration & Air Conditioning Training System PolarX – 584 be expanded?
A: Yes. It can be extended into a full refrigeration circuit using various available models, including the refrigerator module, a refrigeration system with cooling and freezing stages, or an air conditioning module.

Q: How do the models connect to the base unit?
A: Models attach using fasteners and connect hydraulically through refrigerant hoses with self-sealing couplings, and electrically with cables.

Q: What safety features are included?
A: An electronic high pressure switch and an electronic low pressure switch.

Q: How does the software calculate refrigerant mass flow rate?
A: The software uses precise data on the refrigerant’s condition to calculate mass flow rate, a method more precise than traditional measurement techniques.

Q: Is the DAQ software required to operate the base unit?
A: No. The PolarX – 584 software is optional, and a set of electronic sensors is included when the software is used.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Base unit for Refrigeration & Air Conditioning Training System | PolarX – 584 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send the model, quantity, destination and required Incoterm. We will confirm the supplied scope and available export documents.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender that requests a manufacturer authorisation form (MAF)? Send the tender reference, deadline and listed equipment so we can confirm what can be issued.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Refrigeration and Air ConditioningModel PolarX - 584
🏭
Manufacturer DirectProduct-specific enquiry, not a generic catalogue
🌍
Destination MatchedConfiguration and delivery scope reviewed together
📄
Decision-Ready ReplyApplicable documentation confirmed before ordering
Product-specific enquiry

Get a quotation your team can evaluate

A bare price can hide configuration, accessories, voltage, documentation and delivery assumptions. Send the product and destination now so the quoted scope can be reviewed before a purchase decision.

Avoid the mismatchDo not approve a generic price that leaves supplied scope unclear.
Your product is attachedNo need to retype the model or copy the page URL.
Move toward an approvable quoteAdd the destination; quantity and tender details can follow.

No account is required. Organisation, quantity and tender details are optional. Include the country code so the team can reach you internationally.

1993
Manufacturing Since
Direct
Manufacturer Supply
Quote-based
International Orders
Model
PolarX - 584

Overview

The Base unit for Refrigeration & Air Conditioning Training System PolarX - 584 can be extended into a full refrigeration circuit depending on the experiment's objectives. This Base unit for Refrigeration & Air Conditioning Training System supports various available models, including the refrigerator module, a refrigeration system with both cooling and freezing stages, or an air conditioning module.

Product Overview Key components of this training system include the compressor, condenser, receiver, and both electrical and communication systems. The models attach to the base unit and connect hydraulically through refrigerant hoses and electrically with cables. Self-sealing couplings minimize refrigerant loss, and the components are arranged to be clearly visible for monitoring their operation.

The system includes advanced software integrated with the hardware for ease of experimentation and analysis. The experimental unit connects to a PC via USB or LAN. The software includes a system operation and data acquisition program, as well as educational software that aids understanding with explanations and illustrations. Each model has a specific software module tailored to its learning objectives, and teachers can create additional exercises using an authoring system.

Sensors measure temperatures and pressures, which the software displays in real-time for both system operation and data acquisition. The software provides precise data on the refrigerant's condition, allowing for accurate calculations of refrigerant mass flow rate. This method of calculation is more precise than traditional measurement techniques. The software also tracks the effects of parameter changes in a log p-h diagram and optionally allows system operation through the software.

Key Features

Key Features

  • System Type: Base unit for Refrigeration & Air Conditioning Training System, extendable with multiple modules
  • Compressor: Hermetically sealed, 470W refrigeration capacity, 280W power consumption
  • Condenser: Forced air type
  • Liquid Receiver: 0.7L capacity
  • Connectivity: PC connection via USB or LAN, self-sealing refrigerant hose couplings
  • Software: System operation, data acquisition, and educational modules with authoring system
  • Temperature Sensors: 3x, range -100~400°C
  • Pressure Sensors: 1x intake side (-1~15bar), 2x delivery side (-1~25bar)
  • Safety Features: Electronic high pressure switch and electronic low pressure switch
  • Refrigerant: R134A, other refrigerants available on demand
  • Power Analyzer: Displays power, voltage, and current consumed by compressor

Experiments

  • Fundamentals of the refrigeration cycle (in conjunction with its different modules)
  • Fundamentals of air conditioning
  • Components in a refrigeration system/air conditioning system
  • System operation
  • Fault finding

Construction and Design The Base unit for Refrigeration & Air Conditioning Training System PolarX - 584 integrates a condensing unit containing the compressor, condenser, and receiver as its core components. Models attach to the base unit using fasteners and connect hydraulically through refrigerant hoses with self-sealing couplings, and electrically via cables. All components are arranged for clear visibility during operation monitoring. A manometer with an integrated temperature scale supports refrigerant condition readings. Electronic high pressure and low pressure switches provide safety protection. The system connects to a PC via USB or LAN for real-time software-based monitoring and analysis.

Software PolarX - 584 (optional). A DAQ software package, specially designed in National Instruments LABVIEW environment, measures and calculates the results of the apparatus. The software is optional. When the software is used, a set of electronic sensors is included. The software can be run on any Windows environment.

Recommended Accessories (optional)

  • Refrigerator Model, PolarX - 588
  • Model of a Refrigeration System with Refrigeration and Freezing Stage, PolarX - 592
  • Maintenance Kit, PolarX - 596

Scope of Delivery

  • 1 Base Unit
  • 1 instructional manual

Specifications

Base unit for Refrigeration & Air Conditioning Training System PolarX - 584, Technical Specifications

Component Type / Detail
System Function Basic experiments on refrigeration and air conditioning systems via integration with various models
HSI Technology Available as an optional feature
Condensing Unit Compressor, condenser, receiver
Model Connection Refrigerant hoses between condensing unit and models
Model Attachment Firmly attached to the trainer using fasteners
Manometer Includes a temperature scale
Mass Flow Rate Calculation Accurately calculated through software (optional)
Refrigerant R134A (other refrigerants available on demand)
System Control Managed through solenoid valves and software (optional)
Software Functions Educational content, data acquisition, system operation (optional)

Technical Data

Compressor

Parameter Value
Type Hermetically sealed
Refrigeration Capacity 470W
Power Consumption 280W

Liquid Receiver

Parameter Value
Capacity 0.7L

Additional Components

Component Detail
Filter Dryer & Sight Glass Included
Bypass Valves Included

Refrigerant

Parameter Value
Type R134A (other refrigerants available on demand)

Condenser

Parameter Value
Type Forced air

Power Analyzer

Parameter Value
Function Shows power, voltage, and current consumed by compressor

Measuring Ranges - Temperature

Parameter Value
Sensors 3x -100~400°C

Measuring Ranges - Pressure

Parameter Value
Intake Side 1x -1~15bar
Delivery Side 2x -1~25bar

Safety

Component Detail
Electronic High Pressure Switch Included
Electronic Low Pressure Switch Included

Buying Base unit for Refrigeration & Air Conditioning Training System: Distributor & Tender Guidance

Base unit for Refrigeration & Air Conditioning Training System is the product name procurement teams should use when searching, preparing a BOQ or comparing suppliers. A model reference identifies the proposed configuration; it should not replace the product name or the buyer’s required experiment. This equipment is considered for refrigeration and air-conditioning teaching involving cycles, components, psychrometrics, cooling performance or coefficient-of-performance calculations.

What to include in the RFQ

State the product name, quantity, destination, curriculum or tender reference, and cycle or system type, refrigerant, compressor and heat exchangers, measurement points, controls, utilities and experiments. This lets the technical team respond against the intended use rather than guess from a model code.

How distributors should quote it

Keep Base unit for Refrigeration & Air Conditioning Training System as the BOQ line item. Add the proposed model, included accessories, documentation, packing and delivery basis as separate fields so the end buyer can verify the offer.

How to compare suppliers

Compare the actual cycle, instrumented state points and calculations supported by the offered system. Record exclusions and alternatives in writing before commercial comparison.

Specify a modular refrigeration training package

The Base unit for Refrigeration & Air Conditioning Training System | PolarX – 584 is a starting point for a modular training arrangement. Its current product record describes a compressor, condenser and liquid receiver, with refrigeration and air-conditioning modules extending the circuit. The purchasing task is therefore to define a complete usable package, rather than compare the base-unit name alone.

Identify the modules needed for your practical work

A college planning several refrigeration applications should list the exercises it expects the installed system to support. Ask which modules are required for those exercises, which are included in the proposed supply and which are offered separately. A refrigerator module, freezing-stage arrangement and air-conditioning module should not be assumed to arrive together unless the quotation says so.

For a distributor or tender bidder, prepare an item schedule that identifies the base unit and each required module separately. Confirm their compatibility, connection arrangement and any accessories needed to operate the selected combination. This helps avoid comparing a base-unit price with another supplier’s complete teaching package.

Confirm the shared services and recording scope

The product record describes measurement and software functions. Ask the offered specification to identify the actual interface, software, computer requirements and licences supplied with your package. Confirm the site services and working space for the complete assembly, including the selected modules, rather than applying the base unit’s requirements to every possible arrangement.

  • State the exact base model, required modules, quantities and intended practical outcomes.
  • Request a complete list of manuals, connection accessories and separately offered items.
  • Include the delivery country and city and any required commissioning or instructor training.
  • For tenders, request a response against each scheduled component and document requirement.

Keep the chosen configuration visible in the enquiry and written quotation so the laboratory receives a package that matches its approved purchase scope.

Browse refrigeration and air-conditioning equipment · Compare refrigeration trainer families · Request a quotation for Base unit for Refrigeration & Air Conditioning Training System | PolarX – 584

Why Buy From Scientico

🏭

In-House Manufacturer

Designed & built in our Ambala facility since 1993 — not a reseller. Full control over quality & customisation.

✅

Configuration Review

Specifications, documentation and options are confirmed against the selected model.

🌏

International Enquiries

Share your destination and procurement requirements for an export quotation.

📦

Quote-Based Supply

Send the model, quantity and delivery location for a tailored proposal.

🛠

Support Scope

Support and warranty terms are documented in the applicable quotation.

🎓

Built for Teaching

Designed around curriculum experiments with clear, repeatable, hands-on results.

Frequently Asked Questions

Q: Can the Base unit for Refrigeration & Air Conditioning Training System PolarX - 584 be expanded? A: Yes. It can be extended into a full refrigeration circuit using various available models, including the refrigerator module, a refrigeration system with cooling and freezing stages, or an air conditioning module.

Q: How do the models connect to the base unit? A: Models attach using fasteners and connect hydraulically through refrigerant hoses with self-sealing couplings, and electrically with cables.

Q: What safety features are included? A: An electronic high pressure switch and an electronic low pressure switch.

Q: How does the software calculate refrigerant mass flow rate? A: The software uses precise data on the refrigerant's condition to calculate mass flow rate, a method more precise than traditional measurement techniques.

Q: Is the DAQ software required to operate the base unit? A: No. The PolarX - 584 software is optional, and a set of electronic sensors is included when the software is used.

Related Guides & Resources

In-depth guides from Scientico on Refrigeration and Air Conditioning lab setup, experiments and procurement.

Base unit for Refrigeration & Air Conditioning Training System | PolarX - 584

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Automotive Air Conditioning Trainer by Scientico IndiaAutomotive Air Conditioning Trainer | PolarX – 544Building Management System Trainer by Scientico IndiaBuilding Management System Trainer | PolarX – 568Air Duct Training System by Scientico IndiaAir Duct Training System | PolarX – 580Changes of State in Refrigeration Circuit | PolarX – 512, Scientico IndiaChanges of State in Refrigeration Circuit | PolarX – 512Air Duct Apparatus by Scientico IndiaAir Duct Apparatus | PolarX – 576Commercial Refrigeration Training Unit by Scientico IndiaCommercial Refrigeration Training Unit | PolarX – 604Duct type air conditioning trainerAir Conditioning Test Rig (Duct Type) | PolarX 556ADomestic Refrigeration Training Unit by Scientico IndiaDomestic Refrigeration Training Unit | PolarX – 564
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.