🔎 Manufacturer-direct laboratory equipment enquiries - Request a model-specific international quotation →
Established 1993 Model-Specific Specifications Manufacturer-Direct Enquiries International Quotations Destination-Based Delivery Terms

Refrigeration System with Open Compressor | PolarX – 520

The Refrigeration System with Open Compressor PolarX – 520 is a trainer built to make the thermodynamic processes of a refrigeration circuit as transparent as possible. It features an open compressor with variable speed, a water-cooled condenser, a thermostatic expansion valve, and an evaporator heated by a hot water circuit. Pressure and temperature measuring points at all relevant locations allow detailed investigation of pressure and heat losses. This refrigeration system with open compressor supports determination of compressor capacity, refrigeration capacity, compression ratio, volumetric efficiency, and coefficient of performance.

The Refrigeration System with Open Compressor PolarX – 520 is a trainer designed to make the thermodynamic processes in a refrigeration system as transparent as possible. The capacities of the compressor, evaporator, and condenser can all be measured directly. Pressure and temperature measuring points are located at all relevant locations, allowing detailed investigation of pressure and heat losses in the system.

Product Overview

The refrigeration circuit of IRC-1907 contains an open compressor with variable speed, a water-cooled condenser, a thermostatic expansion valve, and an evaporator heated by a hot water circuit. The compressor is driven via a pendulum bearing motor with a frequency converter for speed adjustment. A force transducer permits measurement of the drive torque. Using the speed, the mechanical drive power of the compressor can be determined.

The electrical heating power of the hot water circuit can be freely adjusted and is displayed. Condenser capacity is measured via the cooling water flow. Measured values can be read on digital displays. At the same time, measured values can be transmitted directly to a PC via USB (optional). The software allows the process to be represented in a p-h diagram and displays key characteristic variables of the process, such as compressor pressure ratio and coefficient of performance (optional).

This refrigeration system with open compressor allows detailed investigation of pressure and heat losses, since pressure and temperature measuring points are located at all relevant locations.

Refrigeration System with Open Compressor PolarX – 520, Technical Specifications

Specification Detail
System Investigation Investigation of a refrigeration circuit with speed-controlled compressor
Circuit Configuration Open compressor, condenser, thermostatic expansion valve and evaporator in refrigeration chamber
Cooling Load Control Adjustable via heater in the refrigeration chamber
Condenser and Evaporator With fan
Thermodynamic Cycle Representation P-h diagram (software, optional)
Compressor Efficiency Determinable via measured values
Compressor Flow Rate Effect Investigable on the refrigeration circuit
Pressure Switch Protects the compressor
Sensors Pressure, temperature, power and speed
Refrigerant Mass Flow Rate Calculated in software from recorded measured values (optional)

Technical Data

Open Compressor

Parameter Value
Refrigeration Capacity Approx. 970W (at speed: 1450 min-1 and 5/40°C)

Condenser (with fan)

Parameter Value
Transfer Area 2.5 m2
Capacity Approx. 1950W at 25°C air temperature (ambient), Δt=15°C

Evaporator

Parameter Value
Transfer Area 3.63 m2
Capacity 460W at 3°C air temperature (chamber), Δt=13°C

General

Parameter Value
Heater Power 1000W
Refrigerant R513A
GWP 631 CO2-equivalent

Measuring Ranges

Parameter Value
Temperature 5x -100°C to 400°C
Pressure (Low Side) -1 to 16 bar
Pressure (High Side) -1 to 24 bar
Speed 0 to 1000 min-1
Flow Rate 2 to 18 m3/h

Key Features

  • Transparent Process Design: Thermodynamic processes made as visible as possible for study
  • Measurable Capacities: Compressor, evaporator and condenser capacities can all be measured
  • Measuring Points: Pressure and temperature points at all relevant locations
  • Open Compressor: Variable speed, pendulum bearing motor with frequency converter
  • Drive Torque Measurement: Force transducer determines drive torque and mechanical drive power
  • Condenser: Water-cooled, capacity measured via cooling water flow
  • Evaporator: Heated by hot water circuit, freely adjustable and displayed heating power
  • Expansion Element: Thermostatic expansion valve
  • Digital Displays: Direct reading of measured values
  • USB Data Transfer: Measured values sent to PC in real time (optional)
  • P-h Diagram Software: Displays compressor pressure ratio and coefficient of performance (optional)
  • Trainer Application: This refrigeration system with open compressor supports detailed study of pressure and heat losses

Experiments

  • Fundamentals of refrigeration
  • Design and components of a refrigeration system:
    • Open compressor with drive
    • Condenser
    • Evaporator
    • Thermostatic expansion valve
    • Pressure switch
  • Determination of important characteristic variables:
    • Coefficient of performance
    • Compressor capacity
    • Refrigeration capacity
    • Compression ratio
    • Volumetric efficiency

Construction and Design

The Refrigeration System with Open Compressor PolarX – 520 is built around a refrigeration circuit that includes an open compressor with variable speed, a water-cooled condenser, a thermostatic expansion valve, and an evaporator heated by a hot water circuit. The compressor is driven by a pendulum bearing motor fitted with a frequency converter for speed adjustment. A force transducer measures the drive torque, and the mechanical drive power of the compressor is determined using the speed. The evaporator is located in a refrigeration chamber, with cooling load adjustable via a heater. The condenser and evaporator are each fitted with a fan. Pressure and temperature measuring points are positioned at all relevant locations across this refrigeration system with open compressor, allowing pressure and heat losses to be investigated in detail. A pressure switch protects the compressor. Sensors monitor pressure, temperature, power, and speed throughout the circuit.

Software

Software PolarX – 520 (optional)

DAQ software designed in National Instruments™ LabVIEW™ environment to measure and calculate the results of the apparatus. The software is optional. When the software is used, a set of electronic sensors is included. The software can be run on any Windows™ environment.

Scope of Delivery

  • 1 experimental module
  • 1 instruction manual

Required for Operation

  • Water supply (for the water-cooled condenser and hot water circuit)

Optional Accessories

  • Software PolarX – 520 (DAQ software, National Instruments™ LabVIEW™ environment, requires electronic sensor set)
  • USB data transmission to PC
  • P-h diagram representation in software
  • Refrigerant mass flow rate calculation in software

Q: What does the Refrigeration System with Open Compressor PolarX – 520 demonstrate?
A: It demonstrates the thermodynamic processes of a refrigeration circuit with an open compressor, water-cooled condenser, thermostatic expansion valve, and evaporator heated by a hot water circuit.

Q: How is the drive torque of the compressor measured?
A: A force transducer measures the drive torque, and the mechanical drive power is determined using the speed.

Q: What refrigerant does the unit use?
A: R513A, with a GWP of 631 CO2-equivalent.

Q: Can measured values be transmitted to a PC?
A: Yes, measured values can be transmitted directly to a PC via USB (optional).

Q: Is the PolarX – 520 software required to operate the unit?
A: No, the software is optional. A set of electronic sensors is included when the software is used.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Refrigeration System with Open Compressor | PolarX – 520 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send model, quantity, destination port and Incoterm. Proforma back with the full export documentation set listed.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender? A missing manufacturer authorisation form (MAF) gets a bid rejected before price is opened. Send the tender reference and closing date.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Refrigeration System (Refrigeration & Freezing Chamber) | PolarX – 524, Scientico IndiaRefrigeration System (Refrigeration & Freezing Chamber) | PolarX – 524Refrigeration System with Two-Stage Compression | PolarX – 532Refrigeration Compressor Fault Simulator | PolarX – 572Refrigerator Model | PolarX – 588Recirculating Air Conditioner Trainer | PolarX – 560Reverse Cycle Refrigeration & AC Training Unit | PolarX – 536Model of a Refrigeration System with Refrigeration and Freezing Stage | PolarX – 592Simple Compression Refrigeration | PolarX – 501, Scientico IndiaSimple Compression Refrigeration | PolarX – 501
📄 Download Datasheet