The Recirculating Air Conditioner Trainer PolarX – 560 models a complete air conditioning system with a transparent air duct and climate chamber. This Recirculating Air Conditioner Trainer includes an air cooler with condensing unit (360W, 400W refrigeration capacity), steam humidifier (400W), air heater (600W), and 3 motorized flaps for recirculating and outer air operation. Wet and dry heat sources in the climate chamber, each with 2x 250W heaters, simulate cooling loads, monitored by 5 Type-k temperature sensors. Optional LABVIEW-based DAQ software supports automated data measurement.

The Recirculating Air Conditioner Trainer PolarX – 560 shows a complete air conditioning system with an air duct and climate chamber through a clear, transparent design. This Recirculating Air Conditioner Trainer supports training in air conditioning technology, a key topic in building services engineering.

Product Overview Air conditioning technology has a significant impact on how engineers and skilled personnel are trained. The major elements of this Recirculating Air Conditioner Trainer are the air cooler with a condensing unit, fan, steam humidifier, and air heater. Air distribution in the system is managed by three motorized ventilation flaps.

The climatic chamber contains two different heat sources, wet and dry. Temperature and relative humidity are detected and digitally displayed at relevant locations in the air duct. Two manometers, thermocouples at relevant points, and a flow meter provide the necessary measurements for the refrigeration circuit.

Manual control is used to operate the air conditioning system. A key feature is that the system is fully ready for various automation solutions, so the user can focus on the important topic during a lesson. Available solutions include representation of the circuit in the p-h diagram, effect of a cooling load (dry and wet), mixing different air flows, and representation in the psychometric chart for humid air.

Recirculating Air Conditioner Trainer PolarX – 560, Technical Specifications

Component Type / Detail
System Model Model of an air conditioning system with outer air and recirculating operation
Air Duct Transparent front
Duct Components Fan, air cooler, humidifier, flaps, air heater, sensors
Climate Chamber Wet (latent) and dry (sensible) heat source as cooling load
Flap Control Motorized flaps for recirculating and outer air operation
Process Indication Process with signal lamps
Automation Readiness Ready for different automation solutions
Refrigerant R134a, CFC-free
Expansion Valve Thermostatic

Technical Data

Air-Cooled Condensing Unit

Parameter Value
Power Consumption 360W at -10°C
Refrigeration Capacity 400W at +5/40°C

Humidifier

Parameter Value
Humidifying Power 400W

Air Heater

Parameter Value
Heating Power 600W (selectable in steps), freely adjustable

Chamber Cooling Load

Parameter Value
Heaters 2 heaters in the chamber
Power Output 250W each, freely adjustable

Refrigerant Pressure Gauges

Parameter Value
Suction Side (low pressure gauge) -1~16bar
Delivery Side (high pressure gauge) -1~25bar

Pressure Safety Switch

Side Value
Delivery Side Not specified
Suction Side Not specified

Digital Multifunctional Power Meter

Parameter Value
Range of AC Volt 0~500 volts
Range of AC Ampere 0~40 Ampere

Relative Humidity

Parameter Value
Range 0~100%

Liquid Receiver

Parameter Value
Maximum Working Pressure 450psig
Capacity 1.2L

Filter Drier

Parameter Value
Maximum Working Pressure 450psig

Temperature Sensor

Parameter Value
Range -40~400°C
Type Type-k
Total 05

Duct

Parameter Value
Flow Cross-Section, W x H 150x150mm

Measuring Ranges

Parameter Value
Power Consumption (condensing unit) 0~650W
Power (cooling load) 2x 0~250W
Power (heating power) 0~600W
Flow Rate 0~1.5 LPM
Velocity 0~3m/s

Key Features

  • Trainer Type: Recirculating Air Conditioner Trainer with transparent air duct and climate chamber
  • System Model: Outer air and recirculating operation
  • Major Components: Air cooler with condensing unit, fan, steam humidifier, air heater
  • Flap Control: 3 motorized ventilation flaps for air distribution
  • Climate Chamber: Wet and dry heat sources as cooling load
  • Condensing Unit: 360W consumption, 400W refrigeration capacity
  • Humidifier: 400W humidifying power
  • Air Heater: 600W, selectable in steps
  • Chamber Heaters: 2 x 250W, freely adjustable
  • Temperature Sensors: 5 x Type-k, range -40~400°C
  • Automation Ready: Compatible with various automation solutions

Experiments

  • Representation of the circuit in the p-h diagram
  • Effect of a cooling load (dry and wet)
  • Mixing different air flows
  • Representation in the psychometric chart for humid air
  • Air conditioning system and its components
  • Conditioning room air
  • Humidification and dehumidification
  • Heating and cooling
  • Recirculating and outer air operation
  • Automation in an air conditioning system (in conjunction with optional accessories)

Construction and Design
The Recirculating Air Conditioner Trainer PolarX – 560 features a transparent air duct that displays a complete air conditioning system. The duct houses a fan, air cooler, humidifier, flaps, air heater, and sensors. The climate chamber includes wet and dry heat sources as cooling load. Three motorized flaps manage recirculating and outer air operation, with a process display using signal lamps. Two manometers, thermocouples, and a flow meter provide measurements for the refrigeration circuit. The system uses a thermostatic expansion valve and runs on R134a refrigerant, which is CFC-free.

Software
PolarX – 560 (optional). A DAQ software package, specially designed in National Instruments LABVIEW environment, measures and calculates the results of the apparatus. The software is optional. When the software is used, a set of electronic sensors is included. The software can be run on any Windows environment.

Scope of Delivery

  • 1 Experimental module
  • 1 Instruction manual

Q: What makes this trainer “recirculating”?
A: The Recirculating Air Conditioner Trainer PolarX – 560 models an air conditioning system with both outer air and recirculating operation, controlled by three motorized flaps.

Q: How is the air conditioning system operated?
A: Manual control is used to operate the system, though it is fully ready for various automation solutions.

Q: What heat sources are used in the climate chamber?
A: The chamber contains two different heat sources, wet (latent) and dry (sensible), each with 2 heaters rated at 250W and freely adjustable.

Q: What measurements are available for the refrigeration circuit?
A: Two manometers, thermocouples at relevant points, and a flow meter provide the necessary measurements.

Q: Is the DAQ software required to operate the trainer?
A: No. The PolarX – 560 software is optional, and a set of electronic sensors is included when the software is used.

Need Assistance? We're Here to Help!

Connect with our team for product specifications, pricing, and customized solutions for your institution or project.

Trade enquiries

Distributors, dealers, resellers and bulk buyers

We manufacture Recirculating Air Conditioner Trainer | PolarX – 560 at our own works in Ambala, India. Manufacturer-direct, three ways to work with us.

01

Become a distributor, dealer or agent in your territory

Already selling to colleges or hospitals in your market? Add a manufacturer-direct line. Terms reviewed on application.

or message on WhatsApp
02

Wholesale and bulk quotation

Holding a live enquiry? Send model, quantity, destination port and Incoterm. Proforma back with the full export documentation set listed.

or message on WhatsApp
03

OEM authorisation letter for a tender

Bidding a tender? A missing manufacturer authorisation form (MAF) gets a bid rejected before price is opened. Send the tender reference and closing date.

or message on WhatsApp

Full distributor guide OEM and export enquiries

Refrigeration and Air ConditioningModel PolarX - 560
🏭
Manufacturer DirectProduct-specific enquiry, not a generic catalogue
🌍
Destination MatchedConfiguration and delivery scope reviewed together
📄
Decision-Ready ReplyApplicable documentation confirmed before ordering
Product-specific enquiry

Get a quotation your team can evaluate

A bare price can hide configuration, accessories, voltage, documentation and delivery assumptions. Send the product and destination now so the quoted scope can be reviewed before a purchase decision.

Avoid the mismatchDo not approve a generic price that leaves supplied scope unclear.
Your product is attachedNo need to retype the model or copy the page URL.
Move toward an approvable quoteAdd the destination; quantity and tender details can follow.

No account is required. Organisation, quantity and tender details are optional. Include the country code so the team can reach you internationally.

1993
Manufacturing Since
Direct
Manufacturer Supply
Quote-based
International Orders
Model
PolarX - 560

Overview

The Recirculating Air Conditioner Trainer PolarX - 560 shows a complete air conditioning system with an air duct and climate chamber through a clear, transparent design. This Recirculating Air Conditioner Trainer supports training in air conditioning technology, a key topic in building services engineering.

Product Overview Air conditioning technology has a significant impact on how engineers and skilled personnel are trained. The major elements of this Recirculating Air Conditioner Trainer are the air cooler with a condensing unit, fan, steam humidifier, and air heater. Air distribution in the system is managed by three motorized ventilation flaps.

The climatic chamber contains two different heat sources, wet and dry. Temperature and relative humidity are detected and digitally displayed at relevant locations in the air duct. Two manometers, thermocouples at relevant points, and a flow meter provide the necessary measurements for the refrigeration circuit.

Manual control is used to operate the air conditioning system. A key feature is that the system is fully ready for various automation solutions, so the user can focus on the important topic during a lesson. Available solutions include representation of the circuit in the p-h diagram, effect of a cooling load (dry and wet), mixing different air flows, and representation in the psychometric chart for humid air.

Key Features

Key Features

  • Trainer Type: Recirculating Air Conditioner Trainer with transparent air duct and climate chamber
  • System Model: Outer air and recirculating operation
  • Major Components: Air cooler with condensing unit, fan, steam humidifier, air heater
  • Flap Control: 3 motorized ventilation flaps for air distribution
  • Climate Chamber: Wet and dry heat sources as cooling load
  • Condensing Unit: 360W consumption, 400W refrigeration capacity
  • Humidifier: 400W humidifying power
  • Air Heater: 600W, selectable in steps
  • Chamber Heaters: 2 x 250W, freely adjustable
  • Temperature Sensors: 5 x Type-k, range -40~400°C
  • Automation Ready: Compatible with various automation solutions

Experiments

  • Representation of the circuit in the p-h diagram
  • Effect of a cooling load (dry and wet)
  • Mixing different air flows
  • Representation in the psychometric chart for humid air
  • Air conditioning system and its components
  • Conditioning room air
  • Humidification and dehumidification
  • Heating and cooling
  • Recirculating and outer air operation
  • Automation in an air conditioning system (in conjunction with optional accessories)

Construction and Design The Recirculating Air Conditioner Trainer PolarX - 560 features a transparent air duct that displays a complete air conditioning system. The duct houses a fan, air cooler, humidifier, flaps, air heater, and sensors. The climate chamber includes wet and dry heat sources as cooling load. Three motorized flaps manage recirculating and outer air operation, with a process display using signal lamps. Two manometers, thermocouples, and a flow meter provide measurements for the refrigeration circuit. The system uses a thermostatic expansion valve and runs on R134a refrigerant, which is CFC-free.

Software PolarX - 560 (optional). A DAQ software package, specially designed in National Instruments LABVIEW environment, measures and calculates the results of the apparatus. The software is optional. When the software is used, a set of electronic sensors is included. The software can be run on any Windows environment.

Scope of Delivery

  • 1 Experimental module
  • 1 Instruction manual

Specifications

Recirculating Air Conditioner Trainer PolarX - 560, Technical Specifications

Component Type / Detail
System Model Model of an air conditioning system with outer air and recirculating operation
Air Duct Transparent front
Duct Components Fan, air cooler, humidifier, flaps, air heater, sensors
Climate Chamber Wet (latent) and dry (sensible) heat source as cooling load
Flap Control Motorized flaps for recirculating and outer air operation
Process Indication Process with signal lamps
Automation Readiness Ready for different automation solutions
Refrigerant R134a, CFC-free
Expansion Valve Thermostatic

Technical Data

Air-Cooled Condensing Unit

Parameter Value
Power Consumption 360W at -10°C
Refrigeration Capacity 400W at +5/40°C

Humidifier

Parameter Value
Humidifying Power 400W

Air Heater

Parameter Value
Heating Power 600W (selectable in steps), freely adjustable

Chamber Cooling Load

Parameter Value
Heaters 2 heaters in the chamber
Power Output 250W each, freely adjustable

Refrigerant Pressure Gauges

Parameter Value
Suction Side (low pressure gauge) -1~16bar
Delivery Side (high pressure gauge) -1~25bar

Pressure Safety Switch

Side Value
Delivery Side Not specified
Suction Side Not specified

Digital Multifunctional Power Meter

Parameter Value
Range of AC Volt 0~500 volts
Range of AC Ampere 0~40 Ampere

Relative Humidity

Parameter Value
Range 0~100%

Liquid Receiver

Parameter Value
Maximum Working Pressure 450psig
Capacity 1.2L

Filter Drier

Parameter Value
Maximum Working Pressure 450psig

Temperature Sensor

Parameter Value
Range -40~400°C
Type Type-k
Total 05

Duct

Parameter Value
Flow Cross-Section, W x H 150x150mm

Measuring Ranges

Parameter Value
Power Consumption (condensing unit) 0~650W
Power (cooling load) 2x 0~250W
Power (heating power) 0~600W
Flow Rate 0~1.5 LPM
Velocity 0~3m/s

Buying Recirculating Air Conditioner Trainer: Distributor & Tender Guidance

Recirculating Air Conditioner Trainer is the product name procurement teams should use when searching, preparing a BOQ or comparing suppliers. A model reference identifies the proposed configuration; it should not replace the product name or the buyer’s required experiment. This equipment is considered for refrigeration and air-conditioning teaching involving cycles, components, psychrometrics, cooling performance or coefficient-of-performance calculations.

What to include in the RFQ

State the product name, quantity, destination, curriculum or tender reference, and cycle or system type, refrigerant, compressor and heat exchangers, measurement points, controls, utilities and experiments. This lets the technical team respond against the intended use rather than guess from a model code.

How distributors should quote it

Keep Recirculating Air Conditioner Trainer as the BOQ line item. Add the proposed model, included accessories, documentation, packing and delivery basis as separate fields so the end buyer can verify the offer.

How to compare suppliers

Compare the actual cycle, instrumented state points and calculations supported by the offered system. Record exclusions and alternatives in writing before commercial comparison.

Why Buy From Scientico

🏭

In-House Manufacturer

Designed & built in our Ambala facility since 1993 — not a reseller. Full control over quality & customisation.

✅

Configuration Review

Specifications, documentation and options are confirmed against the selected model.

🌏

International Enquiries

Share your destination and procurement requirements for an export quotation.

📦

Quote-Based Supply

Send the model, quantity and delivery location for a tailored proposal.

🛠

Support Scope

Support and warranty terms are documented in the applicable quotation.

🎓

Built for Teaching

Designed around curriculum experiments with clear, repeatable, hands-on results.

Frequently Asked Questions

Q: What makes this trainer "recirculating"? A: The Recirculating Air Conditioner Trainer PolarX - 560 models an air conditioning system with both outer air and recirculating operation, controlled by three motorized flaps.

Q: How is the air conditioning system operated? A: Manual control is used to operate the system, though it is fully ready for various automation solutions.

Q: What heat sources are used in the climate chamber? A: The chamber contains two different heat sources, wet (latent) and dry (sensible), each with 2 heaters rated at 250W and freely adjustable.

Q: What measurements are available for the refrigeration circuit? A: Two manometers, thermocouples at relevant points, and a flow meter provide the necessary measurements.

Q: Is the DAQ software required to operate the trainer? A: No. The PolarX - 560 software is optional, and a set of electronic sensors is included when the software is used.

Related Guides & Resources

In-depth guides from Scientico on Refrigeration and Air Conditioning lab setup, experiments and procurement.

Recirculating Air Conditioner Trainer | PolarX - 560

Related Laboratory Equipment

Explore related apparatus in this equipment range. Request a model-specific international quotation.

Model of a Refrigeration System with Refrigeration and Freezing Stage | PolarX – 592Refrigerant Recovery and ChargingRefrigerant Recovery and Charging Learning Systems | PolarX-1098Mechanical Heat Pump | PolarX – 540Sophisticated refrigeration components learning systemRefrigeration Components for Advanced Experiments | PolarX-1015Maintenance Kit | PolarX – 596Refrigeration Components for Basic ExperimentsRefrigeration Components for Basic Experiments | PolarX-1011Hermetic Compressor Fault Simulator Trainer | PolarX – 548Refrigeration Compressor Fault Simulator | PolarX – 572
📄 Download Datasheet

Get the product datasheet

Share your details to open the complete datasheet, then print or save it as a PDF.

Recirculating Air Conditioner Trainer | PolarX - 560